A Monte Carlo method to study the response of portable detector to terrestrial gamma ray is proposed. This method is based on two-stage Monte Carlo simulation.First, the probability distributions of the phase space coordinates of the events that are most likely to be detected are reconstructed at the phase space shell level. The phase space shell is a closed surface enclosing the detector. The detector response to events originating from the phase space shell is then studied. The full absorption spectra as well as the partial absorption spectra are obtained for natural radionuclides uniformly distributed in the ground. For validation, this method is applied to a Hp Ge portable detector previously studied. The previous study is based on a semiempirical model. Good agreement is achieved when we compare the full-energy peak efficiencies and the total in situ spectra obtained by the two methods. As an application, the effective depth of the activity of theCs artificial radionuclide in the soil is determined from the low-energy part of the total in situ spectrum.
引用
收藏
页码:52 / 61
页数:10
相关论文
共 50 条
  • [1] Monte Carlo method for determining the response of portable gamma detector for in situ measurement of terrestrial gamma ray field
    Boubaker Askri
    Nuclear Science and Techniques, 2016, 27
  • [2] Monte Carlo method for determining the response of portable gamma detector for in situ measurement of terrestrial gamma ray field
    Askri, Boubaker
    NUCLEAR SCIENCE AND TECHNIQUES, 2016, 27 (04)
  • [3] Monte Carlo based method for conversion of in-situ gamma ray spectra obtained with a portable Ge detector to an incident photon flux energy distribution
    Clouvas, A
    Xanthos, S
    Antonopoulos-Domis, M
    Silva, J
    HEALTH PHYSICS, 1998, 74 (02): : 216 - 230
  • [4] Method for converting in-situ gamma ray spectra of a portable Ge detector to an incident photon flux energy distribution based on Monte Carlo simulation
    Boubaker Askri
    Adel Trabelsi
    Brahim Baccari
    NUCLEAR SCIENCE AND TECHNIQUES, 2008, 19 (06) : 358 - 364
  • [5] Method for converting in-situ gamma ray spectra of a portable Ge detector to an incident photon flux energy distribution based on Monte Carlo simulation
    Boubaker ASKRI
    Adel TRABELSI
    Brahim BACCARI
    NuclearScienceandTechniques, 2008, 19 (06) : 358 - 364
  • [6] Monte Carlo simulation of a position sensitive gamma ray detector
    de Almeida, M
    Moralles, M
    BRAZILIAN JOURNAL OF PHYSICS, 2005, 35 (3B) : 741 - 743
  • [7] MONTE CARLO CALCULATIONS OF SEMICONDUCTOR DETECTOR RESPONSE TO GAMMA RAYS
    WAINIO, KM
    KNOLL, GF
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1965, 8 (01): : 61 - &
  • [8] Application of a Monte Carlo method to the uncertainty assessment in in situ gamma-ray spectrometry
    Persson, Leif
    Boso, Jonas
    Nylen, Torbjorn
    Rameback, Henrik
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2018, 187 : 1 - 7
  • [9] Precise Monte Carlo simulation of gamma-ray response functions for an NaI(Tl) detector
    Shi, HX
    Chen, BX
    Li, TZ
    Yun, D
    APPLIED RADIATION AND ISOTOPES, 2002, 57 (04) : 517 - 524
  • [10] Application of the Monte Carlo method for the calibration of an in situ gamma spectrometer
    Tzika, Faidra
    Kontogeorgakos, Dimitrios
    Vasilopoulou, Theodora
    Stamatelatos, Ion E.
    APPLIED RADIATION AND ISOTOPES, 2010, 68 (7-8) : 1441 - 1444