Application of intraoperative arterial pressure-based cardiac output monitoring for patients undergoing coronary artery bypass grafting surgery

被引:0
|
作者
LU JiakaiZHU ChenJING HeWANG Yijun and QING Enming Department of AnesthesiologyBeijing Anzhen HospitalCapital Medical UniversityBeijing China Department of AnesthesiologyChina Coal General Hospital Beijing China [100029 ,100029 ]
机构
关键词
D O I
暂无
中图分类号
R654.2 [心脏];
学科分类号
1002 ; 100210 ;
摘要
Background For patients undergoing off-pump coronary artery bypass grafting(OPCABG),it is important to establish a hemodynamic monitoring system to obtain powerful parameters for better intraoperative treatment.This study aimed to observe the clinical feasibility of arterial pressure-based cardiac output(APCO) for cardiac output(CO) monitoring and to evaluate the correlation between APCO and pulmonary artery catheter(PAC) for CO measurement for patients undergoing OPCABG intraoperatively. Methods Fifty patients of American Society of Anaesthesiologists(ASA) classificationⅡ-Ⅲ,undergoing elective OPCABG at Beijing Anzhen Hospital were randomly enrolled into this study.All patients were assigned to CO monitoring by PAC and APCO simultaneously.Patients with pacemaker,severe valvular heart disease,left ventricular ejection fraction(EF) <40%,cardiac arrhythmias,peripheral vascular disease,application of intra-aortic balloon pump(IABP) and emergent diversion to cardiac pulmonary bypass were excluded.The radial artery waveform was analyzed to estimate the stroke volume(SV) and heart rate(HR) continuously.CO was calculated as SV x HR;other derived parameters were cardiac index(CI),stroke volume index(SVI),systemic vascular resistance(SVR),and systemic vascular resistance index(SVRI).PAC was placed via right internal jugular vein and the correct position was confirmed by PAC waveforms. Continuous cardiac output(CCO),CI and other hemodynamic parameters were’monitored at following 5 time points: immediate after anesthesia induction(baseline value),anastomosis of left internal mammary artery to left anterior descending artery(LAD),anastomosis of left circumflex(LCX),anastomosis of posterior descending artery(PDA) and immediate after sternal closure. Results In the 50 patients,preoperative echocardiography measured left ventricular EF was(52.8±11.5)%,and 35 patients(70%) showed regional wall’motion abnormalities.The correlation coefficient of CO monitored by APCO and PAC were 0.70,0.59,0.78,0.74 and 0.85 at each time point.The bias range of CI monitored from both APCO and PAC were(0.39±0.06) L·min;·m;,(0.48±0.12) L·min;·m;,(0.26±0.06) L·min;·m;,(0.27±0.06) L·min;·m;,(0.30±0.05) Lmin;·m;at each time point.The results of SVR by two hemodynamic monitoring techniques had good correlation during OPCABG.The variation trends of SVR were opposite comparing with the results of CO.SVR collected from PAC obtained the highest value of(1220.0±254.0) dynscm"5 at PDA anastomosis,but the highest value obtained from APCO was(1206.0±226.5) dyn·s·cm;in LCX anastomosis. Conclusions APCO is feasible in hemodynamic monitoring for patients undergoing OPCABG.The results of hemodynamic monitoring derived from APCO and PAC are closely correlated.Its characterizations of timely,accurate and continuous display of hemodynamic parameters are also obviously demonstrated in the present study.
引用
收藏
页码:2099 / 2103
相关论文
共 50 条
  • [1] Application of intraoperative arterial pressure-based cardiac output monitoring for patients undergoing coronary artery bypass grafting surgery
    Lu Jia-kai
    Zhu Chen
    Jing He
    Wang Yi-jun
    Qing En-ming
    CHINESE MEDICAL JOURNAL, 2012, 125 (12) : 2099 - 2103
  • [2] Comparison of FloTrac™ cardiac output monitoring system in patients undergoing coronary artery bypass grafting with pulmonary artery cardiac output measurements
    Cannesson, M.
    Attof, Y.
    Rosamel, P.
    Joseph, P.
    Bastien, O.
    Lehot, J.-J.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2007, 24 (10) : 832 - 839
  • [3] ARTERIAL PRESSURE-BASED CARDIAC OUTPUT MONITORING, BUT NOT ARTERIAL PRESSURE ITSELF, TRACK CHANGES IN CARDIAC OUTPUT IN PATIENTS WITH SEPSIS
    De Backer, Daniel
    Marx, Gernot
    Tan, Andrew
    Junker, Christopher
    Van Nuffelen, Marc
    Hueter, Lars
    Ching, Willy
    Michard, Frederic
    Vincent, Jean-Louis
    CRITICAL CARE MEDICINE, 2009, 37 (12) : A91 - A91
  • [4] Intraoperative monitoring of patients undergoing port-access coronary artery bypass grafting
    Siegel, LC
    Stevens, JH
    StGoar, FG
    Pompili, MF
    Burdon, TA
    Peters, WS
    Reitz, BA
    ANESTHESIOLOGY, 1996, 85 (3A) : A160 - A160
  • [5] Postoperative atrial fibrillation in patients undergoing coronary artery bypass grafting or cardiac valve surgery: intraoperative use of landiolol
    Kazuhiro Nakanishi
    Shinhiro Takeda
    Chol Kim
    Shusuke Kohda
    Atsuhiro Sakamoto
    Journal of Cardiothoracic Surgery, 8
  • [6] Postoperative atrial fibrillation in patients undergoing coronary artery bypass grafting or cardiac valve surgery: intraoperative use of landiolol
    Nakanishi, Kazuhiro
    Takeda, Shinhiro
    Kim, Chol
    Kohda, Shusuke
    Sakamoto, Atsuhiro
    JOURNAL OF CARDIOTHORACIC SURGERY, 2013, 8
  • [7] Assessment of cardiac biomarkers in patients undergoing coronary artery bypass grafting (CABG) surgery
    Sabah, Enas
    Kamal, Amang
    Al-Saffar, Ahmad
    JOURNAL OF PHARMACOLOGICAL AND TOXICOLOGICAL METHODS, 2016, 81 : 359 - 359
  • [8] Multiple arterial versus single arterial grafting in patients with diabetes undergoing coronary artery bypass surgery
    Alsaleh, Doaa
    Sun, Erick
    Alzahrani, Anas
    Itagaki, Shinobu
    Puskas, John
    Chikwe, Joanna
    Egorova, Natalia
    JTCVS OPEN, 2023, 13 : 119 - 135
  • [9] Cardiac output monitoring: Comparison of a new arterial pressure waveform analysis to the bolus thermodilution technique in patients undergoing off-pump coronary artery bypass surgery
    Mehta, Yatin
    Chand, Rajesh Kumar
    Sawhney, Ravindra
    Bhise, Milind
    Singh, Ajmer
    Trehan, Naresh
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2008, 22 (03) : 394 - 399
  • [10] Arterial pressure-based cardiac output assessment
    Maus, Timothy M.
    Lee, Daniel E.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2008, 22 (03) : 468 - 473