Screening potential P-glycoprotein inhibitors by combination of a detergent-free membrane protein extraction with surface plasmon resonance biosensor

被引:0
|
作者
Yuhong Cao [1 ,2 ]
Jiahao Fang [1 ]
Yiwei Shi [1 ]
Hui Wang [1 ]
Xiaofei Chen [1 ]
Yue Liu [1 ]
Zhenyu Zhu [1 ]
Yan Cao [1 ]
Zhanying Hong [1 ]
Yifeng Chai [1 ]
机构
[1] School of Pharmacy, Second Military Medical University, Shanghai Key Laboratory for Pharmaceutical Metabolites Research
[2] Zhejiang Institute for Food and Drug Control
基金
中国国家自然科学基金;
关键词
D O I
暂无
中图分类号
R965.1 [药物筛选和实验模型];
学科分类号
摘要
P-glycoprotein(P-gp) highly expressed in cancer cells can lead to multidrug resistance(MDR) and the combination of anti-cancer drugs with P-gp inhibitor has been a promising strategy to reverse MDR in cancer treatment. In this study, we established a label-free and detergent-free system combining surface plasmon resonance(SPR) biosensor with styrene maleic acid(SMA) polymer membrane proteins(MPs) stabilization technology to screen potential P-gp inhibitors. First, P-gp was extracted from MCF-7/ADR cells using SMA polymer to form SMA liposomes(SMALPs). Following that, SMALPs were immobilized on an SPR biosensor chip to establish a P-gp inhibitor screening system,and the affinity between P-gp and small molecule ligand was determined. The methodological investigation proved that the screening system had good specificity and stability. Nine P-gp ligands were screened out from 50 natural products, and their affinity constants with P-gp were also determined. The in vitro cell verification experiments demonstrated that tetrandrine, fangchinoline, praeruptorin B, neobaicalein, and icariin could significantly increase the sensitivity of MCF-7/ADR cells to Adriamycin(Adr). Moreover,tetrandrine, praeruptorin B, and neobaicalein could reverse MDR in MCF-7/ADR cells by inhibiting the function of P-gp. This is the first time that SMALPs-based stabilization strategy was applied to SPR analysis system. SMA polymer can retain P-gp in the environment of natural lipid bilayer and thus maintain the correct conformation and physiological functions of P-gp. The developed system can quickly and accurately screen small molecule ligands of complex MPs and obtain affinity between complex MPs and small molecule ligands without protein purification.
引用
收藏
页码:3113 / 3123
页数:11
相关论文
共 24 条
  • [1] Screening potential P-glycoprotein inhibitors by combination of a detergent-free membrane protein extraction with surface plasmon resonance biosensor
    Cao, Yuhong
    Fang, Jiahao
    Shi, Yiwei
    Wang, Hui
    Chen, Xiaofei
    Liu, Yue
    Zhu, Zhenyu
    Cao, Yan
    Hong, Zhanying
    Chai, Yifeng
    ACTA PHARMACEUTICA SINICA B, 2022, 12 (07) : 3113 - 3123
  • [2] Surface plasmon resonance biosensor combined with lentiviral particle stabilization strategy for rapid and specific screening of P-Glycoprotein ligands
    Yuhong Cao
    Yan Cao
    Yiwei Shi
    Ying Cai
    Langdong Chen
    Dongyao Wang
    Yue Liu
    Xiaofei Chen
    Zhenyu Zhu
    Zhanying Hong
    Yifeng Chai
    Analytical and Bioanalytical Chemistry, 2021, 413 : 2021 - 2031
  • [3] Surface plasmon resonance biosensor combined with lentiviral particle stabilization strategy for rapid and specific screening of P-Glycoprotein ligands
    Cao, Yuhong
    Cao, Yan
    Shi, Yiwei
    Cai, Ying
    Chen, Langdong
    Wang, Dongyao
    Liu, Yue
    Chen, Xiaofei
    Zhu, Zhenyu
    Hong, Zhanying
    Chai, Yifeng
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2021, 413 (07) : 2021 - 2031
  • [4] Screening and Identification of Herbal Urease Inhibitors Using Surface Plasmon Resonance Biosensor
    Biglar, Mahmood
    Salehabadi, Hafezeh
    Jabbari, Safoura
    Dabirmanesh, Bahareh
    Khajeh, Khosro
    Mojab, Faraz
    Amanlou, Massoud
    RESEARCH JOURNAL OF PHARMACOGNOSY, 2021, 8 (02) : 51 - 62
  • [5] Selected anthraquinones as potential free radical scavengers and P-glycoprotein inhibitors
    Jeremic, S.
    Amic, A.
    Stanojevic-Pirkovic, M.
    Markovic, Z.
    ORGANIC & BIOMOLECULAR CHEMISTRY, 2018, 16 (11) : 1890 - 1902
  • [6] MOLECULAR STUDY OF P-GLYCOPROTEIN IN MULTIDRUG-RESISTANCE USING SURFACE-PLASMON RESONANCE
    DEMEULE, M
    VACHON, V
    DELISLE, MC
    BEAULIEU, E
    AVERILLBATES, D
    MURPHY, GF
    BELIVEAU, R
    ANALYTICAL BIOCHEMISTRY, 1995, 230 (02) : 239 - 247
  • [7] High-throughput BCRP inhibitors screening system based on styrene maleic acid polymer membrane protein stabilization strategy and surface plasmon resonance biosensor
    Fang, Jiahao
    Shen, Shuqi
    Wang, Hui
    He, Yuzhen
    Chao, Liang
    Cao, Yan
    Chen, Xiaofei
    Zhu, Zhenyu
    Hong, Zhanying
    Chai, Yifeng
    TALANTA, 2024, 274
  • [8] Covalent Design of Cell Membrane Stationary Phase with Enhanced Stability for Fast Screening P-Glycoprotein Inhibitors
    Liu, Yue
    Wang, Xiaoyu
    Gu, Yanqiu
    Zhang, Mingyong
    Cao, Yan
    Zhu, Zhenyu
    Lu, Shan
    Chai, Yifeng
    Chen, Xiaofei
    Hong, Zhanying
    ACS APPLIED BIO MATERIALS, 2020, 3 (08): : 5000 - 5006
  • [9] Development of surface plasmon resonance biosensor assays for primary and secondary screening of acetylcholine binding protein ligands
    Retra, Kim
    Geitmann, Matthis
    Kool, Jeroen
    Smit, August B.
    de Esch, Iwan J. P.
    Danielson, U. Helena
    Irth, Hubertus
    ANALYTICAL BIOCHEMISTRY, 2010, 407 (01) : 58 - 64
  • [10] P1/P1′ modified HIV protease inhibitors as tools in two new sensitive surface plasmon resonance biosensor screening assays
    Alterman, M
    Sjöbom, H
    Säfsten, P
    Markgren, PO
    Danielson, UH
    Hämäläinen, M
    Löfås, S
    Hultén, J
    Classon, B
    Samuelsson, B
    Hallberg, A
    EUROPEAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2001, 13 (02) : 203 - 212