Transcatheter Tricuspid Valve Replacement Following Tricuspid Edge-To-Edge-Repair
被引:0
|作者:
Goldschmied, Andreas
[1
]
Droppa, Michal
[1
]
Gawaz, Meinrad
[1
]
Geisler, Tobias
[1
]
机构:
[1] Univ Hosp Tubingen, Dept Cardiol & Angiol, Otfried Muller Str 10, Tubingen, Baden Wurttembe, Germany
关键词:
EVOQUE;
transcatheter tricuspid valve replacement;
Triclip;
D O I:
10.1002/ccd.31317
中图分类号:
R5 [内科学];
学科分类号:
1002 ;
100201 ;
摘要:
Significant tricuspid regurgitation (TR) is seen as a relevant contributor of cardiac morbidity and mortality. Transcatheter tricuspid valve replacement (TTVR) is a novel technique to treat this condition. We present the case of an 82-year-old lady who was admitted for recurrent right heart decompensation despite having undergone treatment with tricuspid edge-to-edge repair (TEER). The patient underwent transfemoral implantation of a 48 mm EVOQUE valve. Since the implanted Clip was not in the central part of the valve, it was pushed toward the valvular anulus by the expanded prothesis. Echocardiography showed a good result with no residual TR. Options for residual TR after T-TEER are very limited. TTVR might be suitable in selected patients with non-central Clip placement.