Comparing the Accuracy of Conventional Gypsum and 3D-Printed Dental Casts Using Three-Dimensional Analysis

被引:0
|
作者
Thomson, Bradley J. [1 ,2 ]
Hu, Eric [2 ,3 ]
Masterson, Robert [1 ,2 ]
机构
[1] 2 Year Adv Educ Gen Dent Residency Program, Comprehens Dent Dept, Ft Cavazos, TX 76544 USA
[2] JBSA Ft Sam Houston, Uniformed Serv Univ Hlth Sci, Postgrad Dent Coll, Army Postgrad Dent Sch, Ft Sam Houston, TX 78234 USA
[3] 2 Year Adv Educ Gen Dent Residency Program, Prosthodont Dept, Ft Cavazos, TX 76544 USA
关键词
D O I
10.1093/milmed/usae479
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction Dental impressions and casts play a critical role in dental care, facilitating diagnoses and the fabrication of prostheses. Traditional methods of fabrication involve elastomeric materials that are more prone to errors and patient discomfort. Digital advancements offer promising alternatives, yet their accuracy and applicability to military dentistry remain under-explored. This study evaluates the accuracy of digital casts produced with material available in the Military Health System compared to conventional methods.Materials and Methods Using a digital (n = 10) and analog (n = 10) methodology casts were fabricated from a reference cast (n = 1). The reference and cast samples were scanned with a reference scanner to generate stereolithography files. These files were used to generate full arch, single crown, fixed dental prosthesis, and inlay digital casts which were then compared using a three-dimensional (3D) comparison software to evaluate accuracy. Root mean square values were obtained, giving a quantitative evaluation of the deviation of each sample from the reference cast. Statistical analysis consisted of a Shapiro-Wilk and Levene test to account for homogeneity of variances in each group. An ANOVA and Tukey post-hoc test were used to determine differences in accuracy among the full arch and a two-way ANOVA and Tukey post-hoc test evaluated differences in trueness among the casts of the individual preparations.Results Analog full arch casts had an average root mean square of 106 +/- 19.18 mu m when examining trueness and 12 +/- 2.58 mu m for precision. Digital full arch casts had an average root mean square of 51.9 +/- 5.39 mu m when examining trueness and 4.2 +/- 1.57 mu m for precision. Overall digital casts surpassed analog counterparts in accuracy. Fixed dental prostheses were found to be the only group, which showed no statistically significant difference between digital and analog.Conclusion These findings validate the potential of digital workflows in enhancing the speed and accuracy of dental care in the Military Health System, while underscoring the need for further exploration and refinement in specific clinical contexts.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Dimensional accuracy and surface characteristics of 3D-printed dental casts
    Park, Ji-Man
    Jeon, Jin
    Koak, Jai-Young
    Kim, Seong-Kyun
    Heo, Seong-Joo
    JOURNAL OF PROSTHETIC DENTISTRY, 2021, 126 (03): : 427 - 437
  • [2] Evaluation of the dimensional stability of 3D-printed dental casts
    Vincze, Zsofia Eva
    Kovacs, Zoltan Imre
    Vass, Andrea Fanni
    Borbely, Judit
    Marton, Krisztina
    JOURNAL OF DENTISTRY, 2024, 151
  • [3] Evaluation of the accuracy of digital and 3D-printed casts compared with conventional stone casts
    Ellakany, Passent
    Al-Harbi, Fahad
    El Tantawi, Maha
    Mohsen, Cherif
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 127 (03): : 438 - 444
  • [4] Accuracy of Conventional and 3D-Printed Casts for Partial Fixed Prostheses
    Dias Resende, Caio Cesar
    Quirino Barbosa, Tiago Augusto
    Moura, Guilherme Faria
    Rizzante, Fabio Antonio Piola
    Gonzaga, Luiz Henrique
    Januario, Alessandro Lourenco
    Mendonca, Gustavo
    das Neves, Flavio Domingues
    Zancope, Karla
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2024, 37 : S13 - S17
  • [5] Three-Dimensional Evaluation on Accuracy of Conventional and Milled Gypsum Models and 3D Printed Photopolymer Models
    Choi, Jae-Won
    Ahn, Jong-Ju
    Son, Keunbada
    Huh, Jung-Bo
    MATERIALS, 2019, 12 (21)
  • [6] Effect of additive manufacturing process and storage condition on the dimensional accuracy and stability of 3D-printed dental casts
    Yousef, Hazem
    Harris, Bryan T.
    Elathamna, Eiad N.
    Morton, Dean
    Lin, Wei-Shao
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (05): : 1041 - 1046
  • [7] Accuracy of 3-unit fixed dental prostheses fabricated on 3D-printed casts
    Jang, Yeon
    Sim, Ji-Young
    Park, Jong-Kyoung
    Kim, Woong-Chul
    Kim, Hae-Young
    Kim, Ji-Hwan
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 123 (01): : 135 - 142
  • [8] Accuracy of integration of dental casts in three-dimensional models
    Santler, G
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1999, 57 (06) : 666 - 666
  • [9] Trueness of maxillomandibular relationship in 3D-printed and conventional casts
    Auskalnis, Liudas
    Akulauskas, Mykolas
    Osnes, Cecilie
    Revilla-Leon, Marta
    Kernen-Gintaute, Aiste
    Rutkunas, Vygandas
    JOURNAL OF DENTISTRY, 2024, 148
  • [10] Three-dimensional comparative study on the accuracy and reproducibility of dental casts fabricated by 3D printers
    Park, Mid-Eum
    Shin, Soo-Yeon
    JOURNAL OF PROSTHETIC DENTISTRY, 2018, 119 (05): : 861.e1 - 861.e7