Electrochemical detection of lead ions using carbon nanotube post electrodes

被引:2
|
作者
Kumar, Neeraj [1 ]
Tran, Han [2 ]
Shanov, Vesselin N. [2 ]
Alvarez, Noe. T. [1 ]
机构
[1] Univ Cincinnati, Dept Chem, Cincinnati, OH 45221 USA
[2] Univ Cincinnati, Chem Engn Dept, Cincinnati, OH 45221 USA
关键词
Carbon nanotube posts; Electrochemical sensor; Pb ions; Cu ions; Square wave anodic stripping voltammetry; Electrochemical impedance spectroscopy; ANODIC-STRIPPING VOLTAMMETRY; HEAVY-METALS; DRINKING-WATER; SENSOR; TOWER; PB(II); GROWTH; OXIDE;
D O I
10.1016/j.cej.2024.156550
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Heavy metal ions above their recommended limits are highly toxic to human health. Even at low levels, contaminants such as Pb in drinking water can severely affect vulnerable population of the society. Therefore, developing rapid, effective, stable, and convenient sensors for Pb detection has gained significant attention. In this study, considering the excellent properties of carbon nanotubes (CNTs), CNT post electrodes were fabricated by embedding them in a nonconducting polymer. The CNT posts were derived from a closely packed CNT forest with a diameter of 0.3 mm containing millions of vertically aligned pillars. The highly stable CNT post electrodes were employed for the electrochemical sensing of heavy metal ions in 0.1 M citric acid. A linear range of 9.64-168.7 nM (2-35 ppb) was observed for Pb ions. Further, linear ranges of 0.0786-7.86 mu M (5-500 ppb) and 15.73-157.36 mu M (1000-10000 ppb) were also obtained for Cu ions. Notably, the electrode containing a single CNT post was capable of the electrochemical detection of Pb ions at the ppb level. With this electrode, the sensitivity and limit of detection were 0.5095nA/nM and 2 nM (0.5 ppb) for Pb ions, and 24.53 mu A/ppb and 41.67 nM (2.64 ppb) for Cu ions, respectively. The limit of detection for Pb ions is lower than the maximum permissible limit in drinking water set by the World Health Organization. Due the electrochemical method employed on its detection, the reported sensor can simultaneously detect Pb, Cu and Zn ions in tap water.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Electrochemical detection of lead ions using carbon nanotube post electrodes
    Kumar, Neeraj
    Tran, Han
    Shanov, Vesselin N.
    Alvarez, Noe.T.
    Chemical Engineering Journal, 1600, 499
  • [2] Electrochemical Detection of Lead Ions with Ordered Mesoporous Silica–Modified Glassy Carbon Electrodes
    Nicoleta Cotolan
    Liana Maria Mureşan
    Andrea Salis
    Lucian Barbu-Tudoran
    Graziella Liana Turdean
    Water, Air, & Soil Pollution, 2020, 231
  • [3] Electrochemical Detection of Lead Ions with Ordered Mesoporous Silica-Modified Glassy Carbon Electrodes
    Cotolan, Nicoleta
    Muresan, Liana Maria
    Sails, Andrea
    Barbu-Tudoran, Lucian
    Turdean, Graziella Liana
    WATER AIR AND SOIL POLLUTION, 2020, 231 (05):
  • [4] Detection of Trace Heavy Metal Ions Using Carbon Nanotube-Modified Electrodes
    Morton, Jeffrey
    Havens, Nathaniel
    Mugweru, Amos
    Wanekaya, Adam K.
    ELECTROANALYSIS, 2009, 21 (14) : 1597 - 1603
  • [5] Electrochemical detection of amino acids at carbon nanotube and nickel-carbon nanotube modified electrodes
    Deo, RP
    Lawrence, NS
    Wang, J
    ANALYST, 2004, 129 (11) : 1076 - 1081
  • [6] Electrochemical purification of carbon nanotube electrodes
    Heras, Aranzazu
    Colina, Alvaro
    Lopez-Palacios, Jesus
    Ayala, Paola
    Sainio, Jani
    Ruiz, Virginia
    Kauppinen, Esko I.
    ELECTROCHEMISTRY COMMUNICATIONS, 2009, 11 (07) : 1535 - 1538
  • [7] Plasma Activation of Integrated Carbon Nanotube Electrodes for Electrochemical Detection of Catechol
    王升高
    王涛
    李艳琼
    赵修建
    韩建军
    汪建华
    Plasma Science and Technology, 2007, (02) : 194 - 197
  • [8] Plasma activation of integrated carbon nanotube electrodes for electrochemical detection of catechol
    Wang, Shenggao
    Wang, Tao
    Li, Yanqiong
    Zhao, Xiujian
    Han, Jianjun
    Wang, Jianhua
    PLASMA SCIENCE & TECHNOLOGY, 2007, 9 (02) : 194 - 197
  • [9] Electrochemical detection of trace insulin at carbon-nanotube-modified electrodes
    Wang, J
    Musameh, M
    ANALYTICA CHIMICA ACTA, 2004, 511 (01) : 33 - 36
  • [10] Electrochemical detection of anticancer drug lumazine and DNA interaction by using carbon nanotube modified electrodes
    Karadeniz, Hakan
    Eksin, Ece
    Erdem, Arzum
    JOURNAL OF RESEARCH IN PHARMACY, 2019, 23 (04): : 682 - 688