The value of semiquantitative analysis of [99mTc]MDP SPECT/CT in localizing responsible lesions for suspected fresh osteoporotic vertebral compression fractures in patients with contraindications to MRI

被引:0
|
作者
Shi, Sheng [1 ,2 ]
Cai, Hai-Dong [3 ]
Lu, Gai-Xia [3 ]
Zhang, Li-Guo [1 ,2 ]
Zheng, Shuang [4 ]
He, Shi-Sheng [1 ,2 ]
机构
[1] Tongji Univ, Shanghai Peoples Hosp 10, Dept Orthopaed, Shanghai 20072, Peoples R China
[2] Tongji Univ, Spinal Pain Res Inst, Sch Med, Shanghai, Peoples R China
[3] Tongji Univ, Shanghai Peoples Hosp 10, Dept Nucl Med, Shanghai, Peoples R China
[4] Shanghai Univ, Sch Med, Shanghai 200444, Peoples R China
基金
中国国家自然科学基金;
关键词
back pain-inducing test; contraindication to MRI; osteoporotic vertebral compression fracture; relative intensity value; semiquantitative analysis; PERCUTANEOUS VERTEBROPLASTY; PAIN RELIEF; SCINTIGRAPHY; AUGMENTATION;
D O I
10.1111/cpf.12923
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Purpose: The aim of this study was to evaluate the effectiveness of single-photon emission computed tomography/computed tomography (SPECT/CT) in detecting and localizing the causative vertebra in cases of suspected fresh osteoporotic vertebral compression fractures (OVCFs) in patients with contraindications to MRI. Methods: A total of 21 patients with severe back pain with 31 suspected OVCF segments and contraindications to MRI were initially identified through radiographs and the back pain-inducing test (BPIT). The responsible vertebral bodies were determined using [Tc-99m]MDP SPECT/CT before percutaneous vertebroplasty (PVP). Clinical outcomes and radiographic parameters, including basic demographics, injury duration, focal kyphosis (FK), loss of vertebral height (LVH), and relative intensity values (RIVs) for target and nontarget segments in the SPECT/CT were measured. Results: SPECT/CT identified 14 old and 26 fresh OVCFs. Of these, 18 patients with 26 fresh OVCF segments underwent PVP, and achieved satisfactory outcomes. Significant differences were observed in the RIV, FK, and LVH values between the fresh and old OCVF groups (all p < 0.05). RIVs showed a significant negative correlation with injury duration (r = -0.57, p < 0.05), and a positive correlation with LVH (r = 0.43, p < 0.05). Multiple linear regression analysis confirmed that injury duration was an independent predictor of RIVs (p < 0.05). Conclusion: SPECT/CT is useful for detecting and differentiating fresh fractures from old fractures in patients having OVCF who cannot undergo MRI after BPIT validation, allowing these patients to achieve excellent clinical outcomes following PVP. The RIV serves as a valuable parameter for assessing the duration of fresh versus old OVCFs.
引用
收藏
页数:7
相关论文
共 11 条
  • [1] SPECT-CT versus MRI in localizing active lesions in patients with osteoporotic vertebral compression fractures
    Li, Yong-Bo
    Zheng, Xi
    Wang, Rui
    Wu, Han
    Han, Shuo
    Deng, Zhi-Yang
    Sun, Dong
    NUCLEAR MEDICINE COMMUNICATIONS, 2018, 39 (07) : 610 - 617
  • [2] Diagnostic value of SPECT/CT bone imaging in fresh osteoporotic vertebral compression fractures
    Zhao, Yanjun
    Zhang, Di
    Tang, Ping
    HELLENIC JOURNAL OF NUCLEAR MEDICINE, 2022, 25 (02) : 138 - 142
  • [3] The value of combined assessment of vertebral fractures with 99mTc MDP scintigraphy and MRI in selecting and planning percutaneous vertebroplasty
    ap Dafydd, Derfel
    Salem, Shahenda
    Zerizer, Imene
    Mok, Wing Yan
    Gishen, Philip
    Patel, Maneesh C.
    Patel, Neva H.
    Al-Nahhas, Adil
    Dunn, Joel
    Win, Zarni
    NUCLEAR MEDICINE COMMUNICATIONS, 2014, 35 (07) : 755 - 761
  • [4] Added diagnostic value of 99mTc-MDP SPECT/CT for distinguishing vertebral fractures in postmenopausal women
    Qin, Lijun
    Li, Wanting
    Li, Sijin
    Wu, Zhifang
    Liu, Haiyan
    JOURNAL OF NUCLEAR MEDICINE, 2017, 58
  • [5] Differential diagnostic value of SPECT/spiral CT in patients with spinal lesions using 99mTc-MDP
    Shi, Hongcheng
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [6] The value of wrist 99mTC MDP SPECT/CT in identifying the pain generator in both surgical and non-surgical patients
    Ilyas, H.
    Khan, U. Z.
    Ahmed, H.
    Mandegaran, R.
    Vijaynathan, S.
    Hassan, F. U.
    Eccles, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 : S249 - S249
  • [7] Value of 99mTc-MIBI SPECT/CT in the localization of recurrent lesions in patients with suspected recurrent parathyroid carcinoma
    Guo, Yue-Hong
    Huang, Jing-Wei
    Wang, Ying
    Lu, Ruigang
    Yang, Min-Fu
    NUCLEAR MEDICINE COMMUNICATIONS, 2023, 44 (01) : 18 - 26
  • [8] Correlation analysis of the vertebral compression degree and CT HU value in elderly patients with osteoporotic thoracolumbar fractures
    Li, Cheng
    Lai, Xing-ming
    Liu, Nian
    Lin, Yang
    Hu, Wei
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [9] Correlation analysis of the vertebral compression degree and CT HU value in elderly patients with osteoporotic thoracolumbar fractures
    Cheng Li
    Xing-ming Lai
    Nian Liu
    Yang Lin
    Wei Hu
    Journal of Orthopaedic Surgery and Research, 18
  • [10] Diagnostic value of 99mTc-MDP SPECT/spiral CT combined with three-phase bone scintigraphy in assessing suspected bone tumors in patients with no malignant history
    Zhang, Yiqiu
    Shi, Hongcheng
    Li, Beilei
    Xiu, Yan
    Cai, Liang
    Gu, Yushen
    Chen, Shuguang
    NUCLEAR MEDICINE COMMUNICATIONS, 2015, 36 (07) : 686 - 694