Development of an independent calculation program for plan verification in HDR brachytherapy

被引:0
|
作者
La Paz, Franco [1 ]
Alberdi, Mariana [1 ]
Guzman, Karol [1 ]
Juan, Jimena [1 ]
Castano, Adriana [1 ]
Dalla Rosa, Mariela [1 ]
De Rosa, Alejandro [1 ]
Ferreira, Valentina [1 ]
Vega, Carlos [1 ]
Torres, Marcelo [2 ]
Ricagni, Leandro [2 ]
Paolini, Gustavo [1 ]
Quarneti, Aldo [1 ]
Lorenzo, Federico [1 ,2 ]
机构
[1] Ctr Hosp Pereira Rossell, Dept Radiat Oncol, Montevideo, Uruguay
[2] Hosp Clin Montevideo, Dept Radiat Oncol, Montevideo, Uruguay
关键词
Planning; Independent calculation;
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
2155
引用
收藏
页码:S373 / S375
页数:4
相关论文
共 50 条
  • [1] Development of Volumetric Independent Dose Calculation System for Verification of the Treatment Plan in Image-Guided Adaptive Brachytherapy
    Kang, Sang-Won
    Chung, Jin-Beom
    Kim, Kyeong-Hyeon
    Park, Ji-Yeon
    Park, Hae-Jin
    Cho, Woong
    Olberg, Sven
    Suh, Tae Suk
    Park, Justin C.
    FRONTIERS IN ONCOLOGY, 2020, 10
  • [2] A BrachyPhantom for verification of dose calculation of HDR brachytherapy planning system
    Austerlitz, C.
    Campos, C. A. T.
    MEDICAL PHYSICS, 2013, 40 (11)
  • [3] Clinical HDR Brachytherapy Plan Dose Verification for Multiple Channel Cylinders
    Muenkel, J.
    Podder, T.
    MEDICAL PHYSICS, 2018, 45 (06) : E239 - E239
  • [4] Evaluation of an independent dose verification program for HDR planning
    Tong, SD
    Benedict, S
    Todor, D
    Williamson, J
    MEDICAL PHYSICS, 2003, 30 (06) : 1388 - 1388
  • [5] Experimental verification of dose calculation and delivery for the Flexitron HDR Brachytherapy System
    Patel, D.
    Mei, X.
    Kerr, A.
    Joshi, C. P.
    MEDICAL PHYSICS, 2009, 36 (09) : 4304 - 4305
  • [6] Feasibility in using a nomogram as an independent verification process in HDR prostate brachytherapy
    Monasor Denia, P.
    Rodriguez Villalba, S.
    Richart Sancho, J.
    Perez-Calatayud, M. J.
    Santos Ortega, M.
    Perez-Calatayud, J.
    RADIOTHERAPY AND ONCOLOGY, 2021, 158 : S197 - S198
  • [7] Verification of Oncentra brachytherapy planning using independent calculation
    Safian, N. A. M.
    Abdullah, N. H.
    Abdullah, R.
    Chiang, C. S.
    13TH SOUTH-EAST ASIAN CONGRESS OF MEDICAL PHYSICS 2015 (SEACOMP), 2016, 694
  • [8] Development of Dosimetric Verification System for HDR Brachytherapy: A Feasibility Study
    Kang, S.
    Chung, J.
    Cho, W.
    Kang, S.
    Kim, K.
    Shin, D.
    Suh, T.
    MEDICAL PHYSICS, 2020, 47 (06) : E744 - E745
  • [9] Independent brachytherapy plan verification software: Improving efficacy and efficiency
    Damato, Antonio L.
    Devlin, Phillip M.
    Bhagwat, Mandar S.
    Buzurovic, Ivan
    Friesen, Scott
    Hansen, Jorgen L.
    Lee, Larissa J.
    Molodowitch, Christina
    Nguyen, Paul L.
    O'Farrell, Desmond A.
    Viswanathan, Akila N.
    Williams, Christopher L.
    Killoran, Joseph H.
    Cormack, Robert A.
    RADIOTHERAPY AND ONCOLOGY, 2014, 113 (03) : 420 - 424
  • [10] Implementation of a practical independent dose verification program for HDR planning