Decoding Mandibular Angle Fracture Management: Biomechanical Analysis of Different Plating Techniques - An In Vitro Study

被引:0
|
作者
Subramanian, Adalarasan [1 ]
Sambanthan, Thiruneelakandan [1 ]
Punithan, Akash [1 ]
Petchiammal, S. Meera [1 ]
Laxmi, R. Bhuvana [1 ]
Srikanth, Vishal [1 ]
Eswar, E. [1 ]
机构
[1] Govt Dent Coll & Hosp, Dept Oral & Maxillofacial Surg, Cuddalore, Tamil Nadu, India
关键词
Biomechanical analysis; in vitro study; mandibular angle fractures; masticatory loads; three-dimensional curved angle strut plating (3D); FIXATION; REPAIR;
D O I
10.4103/jpbs.jpbs_1285_24
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Objective:The primary rationale of the study is to assess the biomechanical aspects of Champy's, monoplanar, biplanar, and 3D strut plating systems using an in vitro model in the management of the angle of mandible fracture.Methods:Thirty-two hemi-sectioned mandibles (N = 32) were obtained from adult goats and divided into four groups (N = 8) for different plating techniques: monoplanar, biplanar, Champy's, and three-dimensional curved angle strut plating. A customized biomechanical test machine simulated masticatory loads by applying compressive forces. Force versus displacement data were recorded using an Instron Lloyd LRX machine.Results:Plating techniques with two plates exhibited higher resistance to displacement than single-plate techniques. The three-dimensional curved angle strut plate group had the highest mean compressive strength (184.7913 N), followed by biplanar plating (170.29 N), monoplanar plating (159.3419 N), and Champy's plating (55.48375 N). Statistical analysis showed significant differences between the three-dimensional curved angle strut plating technique and Champy's plating technique (P value <= 0.0016*), as well as between the biplanar plating technique and Champy's plating technique (P value <= 0.0010*).Conclusion:The three-dimensional curved angle strut plate and biplanar plating techniques exhibited superior biomechanical performance compared to monoplanar and Champy's plating techniques.
引用
收藏
页码:S4821 / S4825
页数:5
相关论文
共 50 条
  • [1] A biomechanical evaluation of mandibular angle fracture plating techniques
    Haug, RH
    Fattahi, TT
    Goltz, M
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2001, 59 (10) : 1199 - 1210
  • [2] Biomechanical comparison of different plating techniques in repair of mandibular angle fractures
    Alkan, Alper
    Celebi, Nukhet
    Ozden, Bora
    Bas, Burcn
    Inal, Samet
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2007, 104 (06): : 752 - 756
  • [3] A comparison of mandibular angle fracture plating techniques
    Haug, RH
    Barber, JE
    Reifeis, R
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 1996, 82 (03): : 257 - 263
  • [4] A biomechanical evaluation of mandibular condyle fracture plating techniques
    Haug, RH
    Peterson, GP
    Goltz, M
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2002, 60 (01) : 73 - 80
  • [5] A biomechanical evaluation of mandibular condyle fracture plating techniques - Discussion
    Ellis, E
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2002, 60 (01) : 80 - 81
  • [6] A comparative biomechanical evaluation of mandibular condyle fracture plating techniques
    Asprino, L
    Consani, S
    de Moraes, M
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2006, 64 (03) : 452 - 456
  • [7] Plating techniques and plate orientation in repair of mandibular angle fractures: An in vitro study
    Fedok, FG
    Van Kooten, DW
    DeJoseph, LM
    McGinn, JD
    Sobota, B
    Levin, RJ
    Jacobs, CR
    LARYNGOSCOPE, 1998, 108 (08): : 1218 - 1224
  • [8] Biomechanical Comparison of Four Mandibular Angle Fracture Fixation Techniques
    Munante-Cardenas, Jose Luis
    Passeri, Luis Augusto
    CRANIOMAXILLOFACIAL TRAUMA & RECONSTRUCTION, 2015, 8 (02) : 123 - 128
  • [9] Biomechanical evaluation of magnesium plates for management of mandibular angle fracture
    Mohammed, Altaib Abd Al Razik
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2022, 60 (06): : 785 - 790
  • [10] Assessment of the Biomechanical Performance of 5 Plating Techniques in Fixation of Mandibular Subcondylar Fracture Using Finite Element Analysis
    Darwich, Mhd Ayham
    Albogha, Mhd Hassan
    Abdelmajeed, Adnan
    Darwich, Khaldoun
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2016, 74 (04) : 794.e1 - 794.e8