Continuous Glucose Monitoring for Inpatients on Intravenous Insulin

被引:0
|
作者
Good, Karen [1 ]
Joshi, Renu [2 ,3 ]
Snell, Vanessa [1 ]
机构
[1] UPMC Cent Pa, 111 South Front St, Harrisburg, PA 17101 USA
[2] Mt Nittany Med Ctr, State Coll, PA USA
[3] UPMC Cent Pa, Mechanicsburg, PA USA
关键词
continuous glucose monitoring; costs and cost analysis; hypoglycemia; inpatients; insulin; CRITICALLY-ILL PATIENTS; COVID-19; CARE; OUTCOMES; HYPERGLYCEMIA; INJECTIONS; INFUSION;
D O I
10.1097/NUR.0000000000000888
中图分类号
R47 [护理学];
学科分类号
1011 ;
摘要
PurposeThis article describes a protocol used to implement a continuous glucose monitoring program for patients treated with intravenous insulin.DescriptionAlthough continuous glucose monitoring is not indicated for use in hospitalized patients, the COVID-19 pandemic created an immediate need to effectively address the increasing number of people hospitalized with hyperglycemia. The article highlights the implementation process and key glycemic outcomes, discusses the impact of continuous glucose monitoring use on staff time and healthcare resource utilization, and provides information about program expansion.OutcomeMost patients achieved established glycemic targets. Our program improved staff safety by reducing their exposure to infection. Use of continuous glucose monitoring decreased staff time by almost 2 hours per person per day compared with point-of-care testing and resulted in an average cost savings of $278.00 per patient.ConclusionContinuous glucose monitoring is safe and effective in managing glycemia among patients treated with intravenous insulin.
引用
收藏
页码:99 / 106
页数:8
相关论文
共 50 条
  • [1] Continuous glucose monitoring by intravenous microdialysis
    Rooyackers, O.
    Blixt, C.
    Mattsson, P.
    Wernerman, J.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2010, 54 (07) : 841 - 847
  • [2] Insulin pump therapy and continuous glucose monitoring
    Schuetz-Fuhrmann, Ingrid
    Rami-Merhar, Birgit
    Froehlich-Reiterer, Elke
    Hofer, Sabine E.
    Tauschmann, Martin
    Mader, Julia K.
    Resl, Michael
    Kautzky-Willer, Alexandra
    Winhofer-Stoeckl, Yvonne
    Laimer, Markus
    Zlamal-Fortunat, Sandra
    Weitgasser, Raimund
    WIENER KLINISCHE WOCHENSCHRIFT, 2023, 135 (SUPPL 1) : 53 - 61
  • [3] Continuous Glucose Monitoring in Insulin Pump Therapy
    Hermanns, N.
    DIABETOLOGE, 2012, 8 (08): : 662 - 663
  • [4] Insulin pump treatment and continuous glucose monitoring
    Holder, M.
    Deiss, D.
    Lilienthal, E.
    Heidtmann, B.
    MONATSSCHRIFT KINDERHEILKUNDE, 2012, 160 (06) : 593 - 602
  • [5] Insulin pump treatment and continuous glucose monitoring
    Holder, M.
    Deiss, D.
    Lilienthal, E.
    Heidtmann, B.
    DIABETOLOGE, 2013, 9 (01): : 63 - 72
  • [6] IMPROVED BIOASSAY FOR INSULIN BY CONTINUOUS GLUCOSE MONITORING
    KOWARSKI, CR
    KOWARSKI, D
    BICK, BD
    STEIN, H
    RUDZAVICH, D
    KOWARSKI, AA
    JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 1981, 53 (06): : 1145 - 1147
  • [7] Clinical Assessment of Blood Glucose Homeostasis in Horses: Comparison of a Continuous Glucose Monitoring System with a Combined Intravenous Glucose and Insulin Test Protocol
    Johnson, P. J.
    Wiedmeyer, C. E.
    LaCarrubba, A.
    Messer, N. T.
    Dingfelder, H. A.
    Cogswell, A. M.
    Amorim, J. R. R.
    Ganjam, V. K.
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2011, 25 (01) : 162 - 165
  • [8] CONTINUOUS BLOOD GLUCOSE MONITORING SYSTEM USING INTRAVENOUS MICRODIALYSIS AND GLUCOSE SENSING
    Schaller-Ammann, R.
    Greiner, H.
    Huber, A.
    O'Connell, M.
    Krejci, J.
    Porro, G.
    Korsatko, S.
    Gurban, J.
    Deller, S.
    Brunner, M.
    Berghofer, A.
    Priedl, J.
    Zijlstra, E.
    Heise, T.
    Pieber, T. R.
    Schaupp, L.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2013, 15 : A72 - A72
  • [9] Monitoring glucose concentration in patients on intensive intravenous insulin therapy
    Karon, B. S.
    Gandhi, G. Y.
    Nuttall, G. A.
    McMahon, M. M.
    Santrach, P. J.
    CLINICAL CHEMISTRY, 2006, 52 (06) : A188 - A188
  • [10] Insulin Therapy and Blood Glucose Monitoring Evaluation of the Superiority of Glargine as Basal Insulin Replacement by Continuous Glucose Monitoring System
    Wang Xian-ling
    Lu Ju-ming
    Pan Chang-yu
    Mu Yi-ming
    Dou Jing-tao
    Ba Jian-ming
    JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2013, 63 (12)