Repeatability of Microperimetry in Areas of Retinal Pigment Epithelium and Photoreceptor Loss in Geographic Atrophy Supported by Artificial Intelligence-Based Optical Coherence Tomography Biomarker Quantification

被引:1
|
作者
Coulibaly, Leonard m. [1 ]
Birner, Klaudia [1 ]
Zarghami, Azin [1 ]
Gumpinger, Markus [2 ]
Schuerer-waldheim, Simon [2 ]
Fuchs, Philipp [1 ]
Bogunovic, Hrvoje [2 ]
Schmidt-erfurth, Ursula [1 ,2 ]
Reiter, Gregor s. [1 ]
机构
[1] Med Univ Vienna, Dept Ophthalmol & Optometry, Wahringer Gurtel 18-20, A-1090 Vienna, Austria
[2] Med Univ Vienna, Lab Ophthalm Image Anal, Dept Ophthalmol & Optometry, Vienna, Austria
关键词
MACULAR DEGENERATION; END-POINTS; SECONDARY; SENSITIVITY; PROGRESSION; PEGCETACOPLAN;
D O I
10.1016/j.ajo.2024.11.005
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
center dot PURPOSE: Growing interest in microperimetry (MP) or fundus-controlled perimetry as a targeted psychometric testing method in geographic atrophy (GA) is warranted because of the disease subclinical/extrafoveal appearance or preexisting foveal loss with visual acuity becoming unreliable. We provide comprehensive pointwise test-retest repeatability reference values on the most widely used MP devices and combine them with targeted testing in areas of retinal pigment epithelium (RPE) as well as photoreceptor (PR) integrity loss, guiding the interpretation of sensitivity loss during the long-term follow-up of patients with GA. center dot DESIGN: Prospective reliability study. center dot METHODS: Patients with GA underwent consecutive testing on CenterVue (iCare) MAIA and NIDEK MP3 devices. Obtained pointwise sensitivity (PWS) measurements were spatially coregistered to an optical coherence tomography volume scan acquired during the same visit. Areas with RPE and PR integrity loss, drusen, and PR thickness as well as the volume of hyperreflective foci where identified and quantified using a set of validated deep learning-based algorithms. Test-retest repeatability was assessed according to areas defined by biomarkerspecific morphologic changes using Bland-Altmann coefficients of repeatability. Furthermore, the interdevice correlation, the repeatability of scotoma point detection, and any potential effects on fixation stability were assessed. center dot RESULTS: Nine hundred stimuli per device from 20 subjects were included. Identical overall PWS test-retest variance could be detected for MAIA ( +/- 6.57) and MP3 ( +/- 6.59). PR integrity loss was associated with a higher test-retest variance on both devices (MAIA, P = .002; MP3, P < .001). Higher coefficients of repeatability for stimuli in areas presenting RPE loss ( +/- 10.99 vs +/- 5.34) or hyperreflective foci ( +/- 9.21 vs +/- 6.25) could only be detected on MP3 examinations ( P < .001 and P = .01, respectively). An excellent intradevice correlation (MAIA 0.94 [0.93-0.95], MP3 0.94 [0.94-0.95]) and a good mean interdevice correlation (0.84 [0.53-0.92]) were demonstrated. The chosen device, run order, or absence of foveal sparing had no significant effect on fixation stability. center dot CONCLUSION: Areas presenting automatically quantified PR integrity loss with and without underlying RPE loss are associated with higher test-retest variance for both MAIA and MP3. These findings are crucial for an accurate interpretation of GA progression during long-term follow-up and the planning of future trials with MP testing as functional study endpoint. (Am J Ophthalmol 2025;271: 347-359. (c) 2024 The Author(s). Published by Elsevier Inc. This is an open access article under the CC BY license ( http://creativecommons.org/licenses/by/4.0/))
引用
收藏
页码:347 / 359
页数:13
相关论文
共 10 条
  • [1] Photoreceptor loss overlying congenital hypertrophy of the retinal pigment epithelium by optical coherence tomography
    Shields, CL
    Materin, MA
    Walker, C
    Marr, BP
    Shields, JA
    OPHTHALMOLOGY, 2006, 113 (04) : 661 - 665
  • [2] Evaluation of Retinal Pigment Epithelium Atrophy in Age-Related Macular Degeneration: an Artificial Intelligence approach based on Optical Coherence Tomography
    Derradji, Yasmine
    Mosinska, Agata
    De Zanet, Sandro
    Apostolopoulos, Stefanos
    Ciller, Carlos
    Irmela, Mantel
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)
  • [3] Artificial Intelligence Quantified Outer Retinal Disruption On Optical Coherence Tomography As Clinical Endpoints For Geographic Atrophy
    Pely, Adam
    Gao, Simon S.
    Litts, Katie M.
    Wu, Zhichao
    Leng, Theodore
    Steffen, Verena
    Chen, Hao
    Chang, Dolly Shuo-Teh
    Hejrati, Mohsen
    Zhang, Miao
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [4] Quantification of Human Photoreceptor-Retinal Pigment Epithelium Macular Topography with Adaptive Optics-Optical Coherence Tomography
    Liu, Zhuolin
    Aghayee, Samira
    Soltanian-Zadeh, Somayyeh
    Kovalick, Katherine
    Agrawal, Anant
    Saeedi, Osamah
    Cukras, Catherine
    Chew, Emily Y.
    Farsiu, Sina
    Hammer, Daniel X.
    DIAGNOSTICS, 2024, 14 (14)
  • [5] Optical Coherence Tomography Measurements of the Retinal Pigment Epithelium to Bruch Membrane Thickness Around Geographic Atrophy Correlate With Growth
    Chu, Zhongdi
    Shi, Yingying
    Zhou, Xiao
    Wang, Liang
    Zhou, Hao
    Laiginhas, Rita
    Zhang, Qinqin
    Cheng, Yuxuan
    Shen, Mengxi
    de Sisternes, Luis
    Durbin, Mary K.
    Feuer, William
    Gregori, Giovanni
    Rosenfeld, Philip J.
    Wang, Ruikang K.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2022, 236 : 249 - 260
  • [6] Analysis of optical coherence tomography biomarker probability detection in central serous chorioretinopathy by using an artificial intelligence-based biomarker detector
    Desideri, Lorenzo Ferro
    Anguita, Rodrigo
    Berger, Lieselotte E.
    Feenstra, Helena M. A.
    Scandella, Davide
    Sznitman, Raphael
    Boon, Camiel J. F.
    van Dijk, Elon H. C.
    Zinkernagel, Martin S.
    INTERNATIONAL JOURNAL OF RETINA AND VITREOUS, 2024, 10 (01)
  • [7] Artificial intelligence-based prediction of neurocardiovascular risk score from retinal swept-source optical coherence tomography–angiography
    C. Germanese
    A. Anwer
    P. Eid
    L.-A. Steinberg
    C. Guenancia
    P.-H. Gabrielle
    C. Creuzot-Garcher
    F. Meriaudeau
    L. Arnould
    Scientific Reports, 14 (1)
  • [8] Semi-automated quantification of geographic atrophy with blue-light autofluorescence and spectral-domain optical coherence tomography: a comparison between the region finder and the advanced retinal pigment epithelium tool in the clinical setting
    Reumueller, Adrian
    Sacu, Stefan
    Karantonis, Maria Georgia
    Steiner, Irene
    Weigert, Guenther
    Schmidt-Erfurth, Ursula
    ACTA OPHTHALMOLOGICA, 2019, 97 (06) : E887 - E895
  • [9] Comparative quantification of geographic atrophy of the retinal pigment epithelium across color fund us photographs, red-free fundus photographs, and autofluorescence imaging by grader versus automated grading software using optical coherence tomography
    Tadarati, Mongkol
    Chaikitmongkol, Voraporn
    Wolfson, Yulia
    Bressler, Susan B.
    Bressler, Neil M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [10] Are There Coronary Plaque Characteristics Associated With Late Lumen Loss? Artificial Intelligence-Based Optical Coherence Tomography (OCT) Study From the First-in-Human Trial on DREAMS 3G Scaffold
    Garcia, Hector M. Garcia
    Beyene, Solomon
    Melaku, Gebremedhin D.
    Levine, Molly B.
    Haude, Michael
    Wlodarczak, Adrian
    van der Schaaf, Rene J.
    Torzewski, Jan
    Ferdinande, Bert
    Escaned, Javier
    Iglesias, Juan F.
    Bennett, Johan
    Toth, Gabor
    Toelg, Ralph
    Wiemer, Marcus
    Olivecrona, Goran
    Verheye, Stefan
    Joner, Michael
    Antonio Sorolla Romero, Jose
    Waksman, Ron
    JACC-CARDIOVASCULAR INTERVENTIONS, 2023, 16 (04) : S39 - S39