Motor Unit Sampling From Intramuscular Micro-Electrode Array Recordings

被引:0
|
作者
Grison, Agnese [1 ]
Pereda, Jaime Ibanez [1 ,2 ,3 ,4 ]
Farina, Dario [1 ]
机构
[1] Imperial Coll London, Dept Bioengn, London SW7 2AZ, England
[2] Univ Zaragoza, Aragon Inst Engn Res I3A, BSICoS Grp, Zaragoza 50009, Spain
[3] Univ Zaragoza, Inst Invest Sanitaria Aragon IIS Aragon, Zaragoza 50009, Spain
[4] Centrode Invest Biomid Red Bioingn Biomat & Nanome, Zaragoza 50018, Spain
基金
英国工程与自然科学研究理事会; 欧洲研究理事会;
关键词
Motors; Recording; Muscles; Electrodes; Electromyography; Neurons; Accuracy; Convolution; Ankle; Signal resolution; EMG; high-density; intramuscular; motor units; SURFACE EMG; DECOMPOSITION; PHYSIOLOGY; MUSCLES;
D O I
10.1109/TNSRE.2025.3531054
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Recordings of electrical activity from muscles allow us to identify the activity of pools of spinal motor neurons that send the neural drive for muscle activation. Decoding motor unit and motor neuron activity from muscle recordings can be performed by high-density (HD) electrode systems, both non-invasively (surface, HD-sEMG) and invasively (intramuscular, HD-iEMG). HD-sEMG recordings are obtained by grids placed on the skin surface while HD-iEMG signals can be acquired by micro-electrode arrays. While it has been shown that HD-iEMG allows the accurate decoding of a larger number of motor units when compared to HD-sEMG, the dependence of motor unit yield on the parameters of the micro-electrode arrays is still unexplored. Here, we used recently developed HD-iEMG electrodes to record from hundreds of recording sites within the muscle. This allowed us to investigate the impact of electrode number, inter-electrode distance, and the number of muscle insertions on the ability to sample motor units within the muscle. Specifically, we recorded both HD-sEMG and HD-iEMG from the Tibialis Anterior muscle of two healthy subjects at various contraction intensities (10%, 30%, and 70% of maximum voluntary contraction, MVC). For the first time, we present intramuscular recordings with more than 140 electrodes inside a single muscle, achieved through multiple implants of high-density micro-electrode arrays. Through systematic offline analyses of these recordings, we tested different electrode configurations to identify optimal setups for accurately capturing motor unit activity. The results revealed that the density of electrodes in the micro-electrode arrays is the most critical factor for maximising the number of identified motor units and ensuring very high accuracy. Comparisons between intramuscular and surface recordings also confirmed that HD-iEMG consistently captures larger and more stable numbers of motor units across subjects and contraction levels. These results underscore the potential of HD-iEMG as a powerful tool for both clinical and research settings, particularly when precise motor unit decomposition is crucial.
引用
收藏
页码:620 / 629
页数:10
相关论文
共 50 条
  • [1] Simulated micro-electrode array recordings from stem cell-derived cardiomyocytes
    Bowler, Louise
    Harris, Kate
    Gavaghan, David
    Mirams, Gary
    JOURNAL OF PHARMACOLOGICAL AND TOXICOLOGICAL METHODS, 2016, 81 : 380 - 380
  • [2] Stretchable micro-electrode array
    Maghribi, M
    Hamilton, J
    Polla, D
    Rose, K
    Wilson, T
    Krulevitch, P
    2ND ANNUAL INTERNATIONAL IEEE-EMBS SPECIAL TOPIC CONFERENCE ON MICROTECHNOLOGIES IN MEDICINE & BIOLOGY, PROCEEDINGS, 2002, : 80 - 83
  • [3] MICRO-ELECTRODE RECORDINGS FROM RABBIT CILIARY EPITHELIUM INVITRO
    BOUNTRA, C
    GEORGIOU, P
    GREEN, K
    HOUSE, CR
    JOURNAL OF PHYSIOLOGY-LONDON, 1984, 354 (SEP): : P45 - P45
  • [4] MICRO-ELECTRODE RECORDINGS FROM PIGEON LATERAL GENICULATE NUCLEUS
    KINGSMITH, PE
    JOURNAL OF PHYSIOLOGY-LONDON, 1970, 210 (02): : P169 - +
  • [5] Carbon nanotube micro-electrode array
    Gabay, T.
    Ben-David, M.
    Kalifa, I.
    Abrams, Z. R.
    Sorkin, R.
    Ben-Jacob, E.
    Hanein, Y.
    TRANSDUCERS '07 & EUROSENSORS XXI, DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, 2007,
  • [6] Micro-electrode array (MEA) recordings for neurotoxicity screening of new psychoactive substances (NPS)
    Zwartsen, A.
    Hondebrink, L.
    Verboven, A. H. A.
    Drega, S. W.
    Schmeink, S.
    de Groot, M. W. G. D. M.
    van Kleef, R. G. D. M.
    Wijnolts, F. M. J.
    de Groot, A.
    Meulenbelt, J.
    Westerink, R. H. S.
    TOXICOLOGY LETTERS, 2016, 259 : S207 - S207
  • [7] TANTALUM ON SAPPHIRE MICRO-ELECTRODE ARRAY
    MAY, GA
    SHAMMA, SA
    WHITE, RL
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 1979, 26 (12) : 1932 - 1939
  • [8] MICRO-ELECTRODE ARRAYS FOR MULTI-CHANNEL MOTOR UNIT EMG RECORDING
    Yamagiwa, Shota
    Sawahata, Hirohito
    Ishida, Makoto
    Kawano, Takeshi
    2014 IEEE 27TH INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS (MEMS), 2014, : 857 - 860
  • [9] Synchronization of neurons in micro-electrode array cultures
    F. Esposti
    M. G. Signorini
    The European Physical Journal Special Topics, 2008, 165 : 129 - 135
  • [10] A STRETCHABLE MICRO-ELECTRODE ARRAY FOR IN VITRO ELECTROPHYSIOLOGY
    Pakazad, S. Khoshfetrat
    Savov, A. M.
    van de Stolpe, A.
    Braam, S.
    van Meer, B.
    Dekker, R.
    2011 IEEE 24TH INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS (MEMS), 2011, : 829 - 832