Continuous Glucose Monitoring-Derived Glycemic Phenotyping of Childhood Hypoglycemia due to Hyperinsulinism: A Year-long Prospective Nationwide Observational Study

被引:0
|
作者
Worth, Chris [1 ,2 ]
Auckburally, Sameera [1 ,3 ]
Worthington, Sarah [1 ]
Ahmad, Sumera [1 ]
O'Shea, Elaine [1 ]
Senniappan, Senthil [4 ]
Shaikh, Guftar [5 ]
Dastamani, Antonia [6 ]
Ferrara-Cook, Christine [7 ]
Betz, Stephen [7 ]
Salomon-Estebanez, Maria [1 ]
Banerjee, Indraneel [1 ,8 ]
机构
[1] Royal Manchester Childrens Hosp, Dept Paediat Endocrinol, Oxford Rd, Manchester M13 9WL, England
[2] Univ Manchester, Dept Comp Sci, Manchester, England
[3] Univ Lancaster, Fac Hlth & Med, Lancaster, England
[4] Alder Hey Childrens Hosp, Dept Paediat Endocrinol, Liverpool, England
[5] Royal Hosp Children, Dept Paediat Endocrinol, Glasgow, Scotland
[6] Great Ormond St Childrens Hosp, Dept Paediat Endocrinol, London, England
[7] Crinet Pharmaceut, San Diego, CA USA
[8] Univ Manchester, Fac Biol Med & Hlth, Manchester, England
关键词
hyperinsulinism; hypoglycemia; continuous glucose monitoring; pediatrics;
D O I
10.1177/19322968241255842
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The glycemic characterization of congenital hyperinsulinism (HI), a rare disease causing severe hypoglycemia in childhood, is incomplete. Continuous glucose monitoring (CGM) offers deep glycemic phenotyping to understand disease burden and individualize patient care. Typically, CGM has been restricted to severe HI only, with performance being described in short-term, retrospective studies. We have described CGM-derived phenotyping in a prospective, unselected national cohort providing comprehensive baseline information for future therapeutic trials.Methods: Glycemic frequency and trends, point accuracy, and patient experiences were drawn from a prospective, nationwide, observational study of unselected patients with persistent HI using the Dexcom G6 CGM device for 12 months as an additional monitoring tool alongside standard of care self- monitoring blood glucose (SMBG).Findings: Among 45 patients with HI, mean age was six years and 53% carried a genetic diagnosis. Data confirmed higher risk of early morning (03:00-07:00 h) hypoglycemia throughout the study period and demonstrated no longitudinal reduction in hypoglycemia with CGM use. Device accuracy was suboptimal; 17 500 glucose levels paired with SMBG demonstrated mean absolute relative difference (MARD) 25% and hypoglycemia detection of 40%. Patient/parent dissatisfaction with CGM was high; 50% of patients discontinued use, citing inaccuracy and pain. However, qualitative feedback was also positive and families reported improved understanding of glycemic patterns to inform changes in behavior to reduce hypoglycemia.Interpretation: This comprehensive study provides unbiased insights into glycemic frequency and long-term trends among patients with HI; such data are likely to influence and inform clinical priorities and future therapeutic trials.
引用
收藏
页数:10
相关论文
共 19 条
  • [1] Continuous glucose monitoring-derived glycemic metrics and adverse pregnancy outcomes among women with gestational diabetes: a prospective cohort study
    Liang, Xinxiu
    Fu, Yuanqing
    Lu, Sha
    Shuai, Menglei
    Miao, Zelei
    Gou, Wanglong
    Shen, Luqi
    Liang, Yuhui
    Xu, Fengzhe
    Tian, Yunyi
    Wang, Jiali
    Zhang, Ke
    Xiao, Congmei
    Jiang, Zengliang
    Shi, Mei-Qi
    Wu, Ying-Ying
    Wang, Xu-Hong
    Hu, Wen-Sheng
    Zheng, Ju-Sheng
    LANCET REGIONAL HEALTH-WESTERN PACIFIC, 2023, 39
  • [2] Longitudinal association of continuous glucose monitoring-derived metrics with cognitive decline in older adults with type 2 diabetes: A 1-year prospective observational study
    Sugimoto, Taiki
    Tokuda, Haruhiko
    Miura, Hisayuki
    Kawashima, Shuji
    Omura, Takuya
    Ando, Takafumi
    Kuroda, Yujiro
    Matsumoto, Nanae
    Fujita, Kosuke
    Uchida, Kazuaki
    Kishino, Yoshinobu
    Sakurai, Takashi
    DIABETES OBESITY & METABOLISM, 2023, 25 (12): : 3831 - 3836
  • [3] Association between continuous glucose monitoring-derived glycemic control indices and urinary biomarkers of diabetic kidney disease: Hyogo Diabetes Hypoglycemia Cognition Complications study
    Takagi, Ayako
    Kusunoki, Yoshiki
    Ohigashi, Mana
    Osugi, Keiko
    Inoue, Chikako
    Inoue, Maki
    Tsunoda, Taku
    Kadoya, Manabu
    Konishi, Kosuke
    Katsuno, Tomoyuki
    Koyama, Hidenori
    ACTA DIABETOLOGICA, 2024, 61 (04) : 413 - 423
  • [4] Association between continuous glucose monitoring-derived glycemic control indices and urinary biomarkers of diabetic kidney disease: Hyogo Diabetes Hypoglycemia Cognition Complications study
    Ayako Takagi
    Yoshiki Kusunoki
    Mana Ohigashi
    Keiko Osugi
    Chikako Inoue
    Maki Inoue
    Taku Tsunoda
    Manabu Kadoya
    Kosuke Konishi
    Tomoyuki Katsuno
    Hidenori Koyama
    Acta Diabetologica, 2024, 61 : 413 - 423
  • [5] The association of continuous glucose monitoring with glycemic parameters in patients with uncontrolled type 2 diabetes: A prospective observational study
    Chaubey, Abhishek
    Chaubey, Deepika
    Dwivedi, Abhishek
    Dwivedi, Saurabh
    Mishra, Tanu
    JOURNAL OF FAMILY MEDICINE AND PRIMARY CARE, 2024, 13 (08) : 3038 - 3041
  • [6] Evaluation of glycemia risk index and continuous glucose monitoring-derived metrics in type 1 diabetes: a real-world observational study
    Al Hayek, Ayman
    Al Mashali, Malak
    Al Dawish, Mohamed A.
    JOURNAL OF DIABETES AND METABOLIC DISORDERS, 2025, 24 (01)
  • [7] ADEQUACY OF GLYCEMIC CONTROL IN DIABETIC DIALYSIS PATIENTS - A SINGLE CENTRE PROSPECTIVE OBSERVATIONAL STUDY USING CONTINUOUS GLUCOSE MONITORING
    Sharma, S.
    Irvine, D.
    Al-Jumali, T.
    Wijayaratne, K.
    Nama, S.
    Forbes, M.
    Davoren, P.
    Titus, T.
    NEPHROLOGY, 2013, 18 : 68 - 68
  • [8] Mean amplitude of glycemic excursions in septic patients and its association with outcomes: A prospective observational study using continuous glucose monitoring
    Furushima, Nana
    Egi, Moritoki
    Obata, Norihiko
    Sato, Hitoaki
    Mizobuchi, Satoshi
    JOURNAL OF CRITICAL CARE, 2021, 63 : 218 - 222
  • [9] Circulating Polyunsaturated Fatty Acids and Glycemic Dynamics Assessed by Continuous Glucose Monitoring: A 13-Year Prospective Cohort Study
    Chen, Jingnan
    Yan, Yan
    Miao, Zelei
    Zhang, Ke
    Xiao, Congmei
    Liang, Xinxiu
    Xu, Fengzhe
    Gou, Wanglong
    Fu, Yuanqing
    Zhong, Haili
    Chen, Yu-ming
    Zheng, Ju-Sheng
    MOLECULAR NUTRITION & FOOD RESEARCH, 2025,
  • [10] Perception of hyper-/hypoglycemia and its related factors in type 2 diabetes: a continuous glucose monitoring-based prospective observational study
    Suzuki, Yuka
    Miya, Aika
    Nakamura, Akinobu
    Handa, Takahisa
    Kameda, Hiraku
    Atsumi, Tatsuya
    DIABETOLOGY INTERNATIONAL, 2025, : 385 - 393