Biomechanical properties of porcine cornea; planar biaxial tests versus uniaxial tensile tests

被引:0
|
作者
Hatami-Marbini, Hamed [1 ]
Emu, Md Esharuzzaman [1 ]
机构
[1] Univ Illinois, Mech & Ind Engn Dept, Chicago, IL USA
关键词
Porcine cornea; Anisotropy; Biaxial experiments; Uniaxial tensile tests; MECHANICAL-PROPERTIES; BEHAVIOR;
D O I
10.1016/j.jmbbm.2025.106955
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The cornea is a transparent tissue whose mechanical properties are important for its optical and physiological functions. The mechanical properties of cornea depend on the composition and microstructure of its extracellular matrix, which is composed of collagen fibrils with preferential orientations. The present research was done in order to characterize corneal mechanical response using the biaxial mechanical testing method and to compare biaxial measurements with those found from uniaxial tensile tests. For this purpose, thirty square-shaped specimens excised from the center of porcine cornea were mounted into an ElectroForce TestBench device such that their superior/inferior (SI) and nasal/temporal (NT) meridians were aligned with motor axes. Furthermore, ten corneal strips dissected from the NT direction (n = 5) and SI direction (n = 5) were mounted into an RSA-G2 Solid Analyzer testing machine. The biaxial experiments were performed at stretch ratios of 1:1, 1:0.5, 0.5:1, 1:0.01, and 0.01:1 and displacement rates of 2 mm/min (n = 20) and 10 mm/min (n = 10). The uniaxial experiments were done using the displacement rate of 2 mm/min. The planar square-shaped samples tested under equibiaxial loading showed similar mechanical response in NT and SI directions. Furthermore, uniaxial experiments revealed no significant difference in tensile response of corneal strips excised from NT and SI directions. However, equibiaxial testing tensile stresses were significantly larger than those found from uniaxial tensile measurements. The mechanical behavior of cornea in biaxial tests was dependent on the applied stretch ratio. The differences and similarities between uniaxial and biaxial experimental measurements were discussed and it was concluded that the planar biaxial testing method characterized the mechanical response of cornea by mimicking its in vivo loading state more closely than uniaxial experiments.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Biaxial tensile tests of the porcine ascending aorta
    Deplano, Valerie
    Boufi, Mourad
    Boiron, Olivier
    Guivier-Curien, Carine
    Alimi, Yves
    Bertrand, Eric
    JOURNAL OF BIOMECHANICS, 2016, 49 (10) : 2031 - 2037
  • [2] Uniaxial and biaxial tensile tests and analysis of ETFE foils
    Chen, Yu-Feng
    Chen, Wu-Jun
    Zhao, Bing
    Huanan Ligong Daxue Xuebao/Journal of South China University of Technology (Natural Science), 2014, 42 (10): : 125 - 130
  • [3] The influence of the geometry of the porcine cornea on the biomechanical response of inflation tests
    Pandolfi, Anna
    Boschetti, Federica
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2015, 18 (01) : 64 - 77
  • [4] THE CIRCUMFERENTIAL MECHANICAL PROPERTIES OF BAMBOO WITH UNIAXIAL AND BIAXIAL COMPRESSION TESTS
    Jiang, Zehui
    Chen, Fuming
    Wang, Ge
    Liu, Xing'e
    Shi, Sheldon Q.
    Cheng, Hai-tao
    BIORESOURCES, 2012, 7 (04): : 4806 - 4816
  • [5] Biomechanical characterization of cadaveric brachial plexus regions using uniaxial tensile tests
    Perruisseau-Carrier, Anne C.
    Marco, Yann
    Fleury, Vadim
    Jmal, Hamdi
    Brogan, David M.
    Forli, Alexandra
    Bahlouli, Nadia
    HAND SURGERY & REHABILITATION, 2024, 43 (04):
  • [6] UNDERSTANDING THE VISCOELASTIC PROPERTIES OF RABBIT CORNEA BASED ON STRESS RELAXATION TESTS AND CYCLIC UNIAXIAL TESTS
    Zhang, Haixia
    Qian, Xiuqing
    Li, Lin
    Liu, Zhicheng
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2017, 17 (07)
  • [7] POLYESTER SAIL TECHNICAL WOVEN FABRIC BEHAVIOUR UNDER UNIAXIAL AND BIAXIAL TENSILE TESTS
    Ambroziak, Andrzej
    Klosowski, Pawel
    JOURNAL OF THEORETICAL AND APPLIED MECHANICS, 2018, 56 (01) : 227 - 238
  • [8] Basic studies in biaxial tensile tests
    Hartmann S.
    Gilbert R.R.
    Sguazzo C.
    GAMM Mitteilungen, 2018, 41 (01)
  • [9] Energetically stable curve fitting to hyperelastic models based on uniaxial and biaxial tensile tests
    Toth, Brigitta K.
    Lengyel, Andras
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2024, 153
  • [10] Failure analysis based on microvoid growth for sheet metal during uniaxial and biaxial tensile tests
    Abbassi, Fethi
    Mistou, Sebastien
    Zghal, Ali
    MATERIALS & DESIGN, 2013, 49 : 638 - 646