Case Report: Facial fracture sequelae: the importance of using a specific customized implant (PSI) for orbital reconstruction

被引:0
|
作者
Pulino, Bianca [1 ,2 ]
Fonseca, Leonardo Alckmin Hotz [1 ]
Vieira, Eduardo Hochuli [2 ,3 ]
Piteri Filho, Jose Roberto [1 ]
de Macedo, Thiago Felippe Oliveira [1 ]
D'Amado, Marcelo Pigatto [4 ]
Pereira, Rodrigo [5 ]
Santos, Igor Alexandre Damasceno [6 ]
Ilesan, Robert [7 ]
Moreira, Henrique Cabrini [8 ]
Viana, Drielli [9 ]
Guerra, Raphael Capelli [1 ,2 ]
机构
[1] Sirio Libanes Teaching & Res Inst, Dept Oral & Maxillofacial Surg, Sao Paulo, Brazil
[2] Leforte Dasa Hosp, Dept Oral & Maxillofacial Surg, Sao Paulo, Brazil
[3] Sao Paulo State Univ, Dept Oral & Maxillofacial Surg, Sao Paulo, Brazil
[4] Sirio Libanes Teaching & Res Inst, Sao Paulo, Brazil
[5] Grande Rio Univ UNIGRANRIO, Dept Oral & Maxillofacial Surg, Rio De Janeiro, Brazil
[6] Univ Fed Bahia, Dept Oral & Maxillofacial Surg, Salvador, BA, Brazil
[7] Univ Hosp Basel, Dept Craniomaxillofacial Surg, Basel, Switzerland
[8] Municipal Hosp Doutor Arthur Ribeiro Saboya, Sao Paulo, Brazil
[9] Univ Nove Julho, Dept Oral & Maxillofacial Surg, Sao Paulo, Brazil
来源
FRONTIERS IN SURGERY | 2024年 / 11卷
关键词
orbital fracture; reconstruction; 3D printed; titanium implants; custom-made implants; BLOWOUT FRACTURES; FLOOR; SURGERY;
D O I
10.3389/fsurg.2024.1425905
中图分类号
R61 [外科手术学];
学科分类号
摘要
The reconstruction of orbital fracture sequelae is a major challenge due to concerns regarding surgical approach and implant stability. Few anatomical sites of such minute size have presented with as much variation in treatment as the orbital floor fractures and related sequelae. Our patient developed sequelae of an orbital fracture over the last 3 years, presenting with dystopia, ophthalmoplegia, and diplopia in the supra- and lateroversion and aesthetic impairment. The variety of implant materials for reconstruction after orbital fractures is extensive, and the decision as to which material to use continues to be debated. The continuing development of computer-aided diagnosis and management and the construction of stereolithographic models offer comparable reproduction of anatomical detail. This technology is described in relation to the planning of trauma surgery and sequelae and the planning of ablative surgery for malignant neoplasms of the head and neck. The use of specific 3D printed titanium implants for bone defects was first reported in cranial reconstruction in 2012, and several studies have reported their use in orbital fractures. The advantages of this implant were increased stiffness, preventing shape loss during placement, a precise fit, and decreased surgical time. However, in the existing literature, the one-piece implant done in this way was a precise fit; therefore, it is possible that navigation between intraoperative anatomical landmarks is lost. However, in cases where reconstruction is difficult, such as extensive orbital wall fractures and large orbital sequelae, the 3D printed implant has been helpful in decreasing surgical time and can be accessed by a limited surgical approach with a precise fit. Our clinical case involved a 37-year-old male patient who experienced severe physical aggression in 2020, amid the COVID-19 pandemic. At the time, due to the overwhelming healthcare demands and resource constraints imposed by the pandemic, immediate surgical intervention for the correction of the fracture was not feasible. As a result of this delay, the patient developed sequelae of the orbital fracture over the last 3 years.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Patient-Specific Implant for Primary Orbital Reconstruction: A Case Report
    Jennifer, Ting
    Isa, Mohd Ferdaus
    Rajaran, Jothi Raamahlingam
    Nazimi, Abd Jabar
    ARCHIVES OF OROFACIAL SCIENCE, 2022, 17 (02): : 259 - 267
  • [2] PSI: Planner-specific, physician-specific, or patient-specific implant for orbital reconstruction?
    Sabelis, J. F.
    Shaheen, E.
    Willaert, R.
    Becking, A. G.
    Dubois, L.
    Schreurs, R.
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2024, 52 (11) : 1376 - 1382
  • [3] FRACTURE OF ORBITAL FLOOR - CASE REPORT WITH SERIOUS DELAYED SEQUELAE
    ROGERS, PA
    NARDI, W
    MEDICAL JOURNAL OF AUSTRALIA, 1973, 1 (04) : 175 - 176
  • [4] Generation of customized orbital implant templates using 3-dimensional printing for orbital wall reconstruction
    Sunah Kang
    Jaeyoung Kwon
    Chan Joo Ahn
    Bita Esmaeli
    Guk Bae Kim
    Namkug Kim
    Ho-Seok Sa
    Eye, 2018, 32 : 1864 - 1870
  • [5] Generation of customized orbital implant templates using 3-dimensional printing for orbital wall reconstruction
    Kang, Sunah
    Kwon, Jaeyoung
    Ahn, Chan Joo
    Esmaeli, Bita
    Kim, Guk Bae
    Kim, Namkug
    Sa, Ho-Seok
    EYE, 2018, 32 (12) : 1864 - 1870
  • [6] Orbital Reconstruction: Patient-Specific Orbital Floor Reconstruction Using a Mirroring Technique and a Customized Titanium Mesh
    Tarsitano, Achille
    Badiali, Giovanni
    Pizzigallo, Angelo
    Marchetti, Claudio
    JOURNAL OF CRANIOFACIAL SURGERY, 2016, 27 (07) : 1822 - 1825
  • [7] Orbital Reconstruction Using a Polyetheretherketone Patient-Specific Implant After Removal of a Mucocele Developing After Orbital Fracture Repair
    Lee, Junho
    Choi, Young Jae
    Rha, Eun Young
    JOURNAL OF CRANIOFACIAL SURGERY, 2023, 34 (08) : 2321 - 2322
  • [8] Miscellaneous orbital implant for anophthalmic cavity reconstruction surgery: case report
    Araf, Davi
    Assae, Omar Massayoshi
    de Brito, Rodrigo Vuono
    Aquino, Guido, Jr.
    Gomes da Silva, Tania Aleksandra
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2010, 73 (01) : 81 - 83
  • [9] Customized orbital implant versus 3D preformed titanium mesh for orbital fracture repair: A retrospective comparative analysis of orbital reconstruction accuracy
    Consorti, Giuseppe
    Betti, Enrico
    Catarzi, Lisa
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2024, 52 (04) : 532 - 537
  • [10] FACIAL-PAIN DUE TO A DISPLACED ORBITAL FLOOR IMPLANT - REPORT OF CASE
    PEAK, J
    HARIA, S
    SLEEMAN, D
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1992, 50 (11) : 1234 - 1235