First Dosimetric and Biological Verification for Spot-Scanning Hadron Arc Radiation Therapy With Carbon Ions

被引:0
|
作者
Tessonnier, Thomas [1 ,2 ]
Filosa, Domenico Ivan [3 ,4 ]
Karle, Celine [5 ,6 ,7 ,8 ,9 ,10 ,11 ]
Baltazar, Filipa [2 ,7 ,8 ,9 ,10 ,11 ]
Manti, Lorenzo [3 ,4 ]
Glimelius, Lars [12 ]
Haberer, Thomas [1 ]
Abdollahi, Amir [1 ,5 ,6 ,7 ,8 ,9 ,10 ,13 ]
Debus, Juergen [1 ,2 ,7 ,8 ,9 ,10 ,11 ,13 ]
Mein, Stewart [1 ,5 ,6 ,7 ,8 ,9 ,10 ,14 ]
Dokic, Ivana [1 ,5 ,6 ,7 ,8 ,9 ,10 ]
Mairani, Andrea [1 ,5 ,6 ,15 ,16 ]
机构
[1] Heidelberg Univ Hosp, Heidelberg Ion Beam Therapy Ctr, Dept Radiat Oncol, Heidelberg, Germany
[2] German Canc Res Ctr, Clin Cooperat Unit Radiat Oncol E050, Heidelberg, Germany
[3] Univ Naples Federico II, Dept Phys Ettore Pancini, I-80126 Naples, Italy
[4] Sez Napoli, Ist Nazl Fis Nucl, Naples, Italy
[5] Heidelberg Univ Hosp, Natl Ctr Tumor Dis, Clin Cooperat Unit Translat Radiat Oncol E210, Heidelberg, Germany
[6] German Canc Res Ctr, Heidelberg, Germany
[7] Heidelberg Fac Med, Dept Radiat Oncol, Div Mol & Translat Radiat Oncol, Heidelberg, Germany
[8] Heidelberg Univ Hosp, Heidelberg Ion Beam Therapy Ctr, Heidelberg, Germany
[9] German Canc Res Ctr, German Canc Consortium Core, Ctr Heidelberg, Heidelberg, Germany
[10] Natl Ctr Radiat Res Oncol NCRO, Heidelberg Inst Radiat Oncol, Heidelberg, Germany
[11] Heidelberg Univ, Dept Phys & Astron, Heidelberg, Germany
[12] RaySearch Labs, Stockholm, Sweden
[13] Heidelberg Univ Hosp, Dept Radiat Oncol, Heidelberg, Germany
[14] Univ Penn, Dept Radiat Oncol, Philadelphia, PA USA
[15] Natl Ctr Tumor Dis, Heidelberg, Germany
[16] Natl Ctr Oncol Hadrontherapy, Med Phys, Pavia, Italy
关键词
IN-VIVO; PROTON; RBE;
D O I
10.1016/j.adro.2024.101611
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Spot-scanning hadron arc radiation therapy (SHArc) is a novel delivery technique for ion beams with potentially improved dose conformity and dose-averaged linear energy transfer (LETd) redistribution. The fi rst dosimetric validation and in vitro verification of carbon ion arc delivery is presented. Methods and Materials: Intensity-modulated particle therapy (IMPT) and SHArc plans were designed to deliver homogeneous physical dose or biological dose in a cylindrical polymethyl methacrylate (PMMA) phantom. Additional IMPT carbon plans were optimized for testing different LETd-boosting strategies. Verifications of planned doses were performed with an ionization chamber, and a clonogenic survival assay was conducted using A549 cancer lung cell line. Radiation-induced nuclear 53BP1 foci were assessed to evaluate the cellular response in both normoxic and hypoxic conditions. Results: Dosimetric measurements and clonogenic assay results showed a good agreement with planned dose and survival distributions. Measured survival fractions and foci confirmed carbon ions SHArc as a potential modality to overcome hypoxia-induced radioresistance. LETd-boosted IMPT plans reached similar LETd in the target as in SHArc plans, promising similar features against hypoxia but at the cost of an increased entrance dose. SHArc resulted, however, in a lower dose bath but in a larger volume around the target. Conclusions: The fi rst proof-of-principle of carbon ions SHArc delivery was performed, and experimental evidence suggests this novel modality as an attractive approach for treating hypoxic tumors. (c) 2024 Published by Elsevier Inc. on behalf of American Society for Radiation Oncology. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Spot-Scanning Hadron Arc (SHArc) Therapy: A Study With Light and Heavy Ions
    Mein, Stewart
    Tessonnier, Thomas
    Kopp, Benedikt
    Harrabi, Semi
    Abdollahi, Amir
    Debus, Juergen
    Haberer, Thomas
    Mairani, Andrea
    ADVANCES IN RADIATION ONCOLOGY, 2021, 6 (03)
  • [2] The first investigation of the dosimetric perturbations from the spot position errors in spot-scanning arc therapy (SPArc)
    Liu, Peilin
    Zhao, Lewei
    Liu, Gang
    Cong, Xiaoda
    Li, Xiaoqiang
    Ding, Xuanfeng
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (13):
  • [3] Development and Evaluation of Spot-Scanning Hadron Arc (SHArc) Therapy Using Light and Heavy Ions
    Mein, S.
    Kopp, B.
    Tessonnier, T.
    Liermann, J.
    Harrabi, S.
    Debus, J.
    Schoemers, C.
    Abdollahi, A.
    Haberer, T.
    Mairani, A.
    MEDICAL PHYSICS, 2022, 49 (06) : E210 - E211
  • [4] Next Evolutions in Particle Therapy: Spot-Scanning Hadron Arc (SHArc) Therapy
    Mein, S.
    Tessonnier, T.
    Kopp, B.
    Debus, J.
    Haberer, T.
    Abdollahi, A.
    Mairani, A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2021, 111 (03): : S139 - S140
  • [5] Spot-Scanning Proton Arc (SPArc) Therapy: The First Robust and Delivery-Efficient Spot-Scanning Proton Arc Therapy
    Ding, Xuanfeng
    Li, Xiaoqiang
    Zhang, J. Michele
    Kabolizadeh, Peyman
    Stevens, Craig
    Yan, Di
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (05): : 1107 - 1116
  • [6] From Concept to First Delivery of the Spot-Scanning Proton Arc Therapy
    Li, X.
    Liu, G.
    Janssens, G.
    De Wilde, O.
    Bossier, V.
    Lerot, X.
    Pouppez, A.
    Yan, D.
    Stevens, C.
    Kabolizadeh, P.
    Ding, X.
    MEDICAL PHYSICS, 2019, 46 (06) : E290 - E290
  • [7] Assessing Clinical and Dosimetric Benefits of Spot-Scanning Proton Arc Therapy in Ocular Melanoma Treatment
    Cao, X.
    Liu, P.
    Deraniyagala, R. L., Jr.
    Zureick, A. H.
    Mamalui-Hunter, M.
    Dagan, R.
    Rutenberg, M. S.
    Zhao, L.
    Liu, G.
    Stevens, C. W.
    Li, X.
    Ding, X.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2024, 120 (02): : E737 - E737
  • [8] Spot-scanning hadron arc (SHArc) therapy: A proof of concept using single- and multi-ion strategies with helium, carbon, oxygen, and neon ions
    Mein, Stewart
    Kopp, Benedikt
    Tessonnier, Thomas
    Liermann, Jakob
    Abdollahi, Amir
    Debus, Juergen
    Haberer, Thomas
    Mairani, Andrea
    MEDICAL PHYSICS, 2022, 49 (09) : 6082 - 6097
  • [9] Three-dimensional dosimetric verification of spot-scanning proton therapy in a breast-shaped phantom
    Jensen, S. E.
    Valdetaro, L. Barbosa
    Jensen, M. Fuglsang
    Balling, P.
    Skyt, P. Sandegaard
    Petersen, J. Breede Baltzer
    Muren, L. Paul
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S463 - S464
  • [10] The First Prototype of Spot-Scanning Proton Arc Treatment Delivery
    Li, X.
    Liu, G.
    Janssens, G.
    De Wilde, O.
    Bossier, V.
    Lerot, X.
    Pouppez, A.
    Yan, D.
    Stevens, C. W.
    Kabolizadeh, P.
    Ding, X.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (01): : S242 - S242