A Multianalyte Machine Learning Model to Detect Wrong Blood in Complete Blood Count Tube Errors in a Pediatric Setting

被引:0
|
作者
Graham, Brendan, V [1 ]
Master, Stephen R. [1 ,2 ]
Obstfeld, Amrom E. [1 ,2 ]
Wilson, Robert B. [1 ,2 ]
机构
[1] Childrens Hosp Philadelphia, Dept Pathol & Lab Med, Main Bldg,5-137,3401 Civic Ctr Blvd, Philadelphia, PA 19104 USA
[2] Univ Penn, Dept Pathol & Lab Med, Philadelphia, PA USA
关键词
OUTCOMES;
D O I
10.1093/clinchem/hvae210
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background Multianalyte machine learning (ML) models can potentially identify previously undetectable wrong blood in tube (WBIT) errors, improving upon current single-analyte delta check methodology. However, WBIT detection model performance has not been assessed in a real-world, low-prevalence context. To estimate real-world positive predictive values, we propose a methodology to assess WBIT detection models by evaluating the impact of missing data and by using a "low prevalence" validation data set.Methods We trained a range of model specifications using various predictors in a pediatric setting. We assessed the top-performing model on a modified, "low prevalence" validation data set across a range of probability thresholds. Model performance was also compared to a pre-positive patient identification (pre-PPID) dataset.Results An Extreme Gradient Boosting (XGBoost) model with minimal preprocessing performed the best for both complete blood count with differential white cell count (CBC with Diff) tests (accuracy 0.9715) and complete blood count without differential white cell count (CBC without Diff) tests (accuracy 0.9647). Assessment on a downsampled, "low prevalence" validation data set resulted in estimated positive predictive values ranging from 0.01 to 0.67 (CBC with Diff) and 0.01 to 0.75 (CBC without Diff), depending on the probability threshold chosen. A comparison of prospective performance to PPID data demonstrated a large decrease in estimated WBIT errors.Conclusions We find that ML models can accurately predict WBITs in a primarily pediatric setting. Evaluating model performance across a range of probability thresholds minimizes the number of false positives while still providing added safety benefits. The decrease in estimated WBITS post-PPID implementation shows the potential safety benefits of a WBIT model for hospitals not using PPID when collecting laboratory specimens.
引用
收藏
页码:418 / 427
页数:10
相关论文
共 50 条
  • [1] A Machine Learning Model for the Routine Detection of "Wrong Blood in Complete Blood Count Tube" Errors
    Farrell, Christopher-John
    Makuni, Charles
    Keenan, Aaron
    Maeder, Ellena
    Davies, Gareth
    Giannoutsos, John
    CLINICAL CHEMISTRY, 2023, 69 (09) : 1031 - 1037
  • [2] Using Machine Learning-Based Multianalyte Delta Checks to Detect Wrong Blood in Tube Errors
    Rosenbaum, Matthew W.
    Baron, Jason M.
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2018, 150 (06) : 555 - 566
  • [3] Machine learning models outperform manual result review for the identification of wrong blood in tube errors in complete blood count results
    Farrell, Christopher-John L.
    Giannoutsos, John
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2022, 44 (03) : 497 - 503
  • [4] Using Blood Donor-Derived ABO and RhD Blood Groups Helps to Detect Wrong Blood in Tube Errors in Recipients
    Dellgren, Christoffer
    Yazer, Mark H.
    Sprogoe, Ulrik
    TRANSFUSION MEDICINE AND HEMOTHERAPY, 2017, 44 (06) : 422 - 425
  • [5] COMPLETE BLOOD COUNT BASED MACHINE LEARNING ALGORITHMS FOR SEPSIS DETECTION
    Urrechaga, Eloisa
    Fernandez, Monica
    Burzako, Arantza
    Aguirre, Urko
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2024, 46 : 106 - 107
  • [6] Mislabeled Samples Frequently Contain Wrong Blood in Tube Errors
    Yazer, Mark H.
    Chasse, Danielle
    Dinh, Anh
    Dunbar, Nancy M.
    Flanagan, Peter
    Gabert, Kimberly
    Jackson, Bryon
    Lane, Debra
    Murphy, Michael
    Ray, Charles
    Staves, Julie
    Kaufman, Richard M.
    TRANSFUSION, 2018, 58 : 119A - 119A
  • [7] Wrong Blood-In-Tube Errors more common in Emergency Departments
    Krome, Susanne
    TRANSFUSIONSMEDIZIN, 2022, 12 (01) : 13 - 13
  • [8] Interventions to Reduce Wrong Blood in Tube Errors in Transfusion: A Systematic Review
    Cottrell, Susan
    Watson, Douglas
    Eyre, Toby A.
    Brunskill, Susan J.
    Doree, Carolyn
    Murphy, Michael F.
    TRANSFUSION MEDICINE REVIEWS, 2013, 27 (04) : 197 - 205
  • [9] Detecting 'wrong blood in tube' errors: Evaluation of a Bayesian network approach
    Doctor, Jason N.
    Strylewicz, Greg
    ARTIFICIAL INTELLIGENCE IN MEDICINE, 2010, 50 (02) : 75 - 82
  • [10] Early Colorectal Cancer Detected by Machine Learning Model Using Gender, Age, and Complete Blood Count Data
    Hornbrook, Mark C.
    Goshen, Ran
    Choman, Eran
    O'Keeffe-Rosetti, Maureen
    Kinar, Yaron
    Liles, Elizabeth G.
    Rust, Kristal C.
    DIGESTIVE DISEASES AND SCIENCES, 2017, 62 (10) : 2719 - 2727