Investigate the dosimetric impact from spot position perturbations between SPArc therapy and IMPT

被引:0
|
作者
Liu, Peilin [1 ]
Cong, Xiaoda [1 ]
Liu, Gang [1 ,2 ]
Zhao, Lewei [1 ,3 ]
Li, Xiaoqiang [1 ]
Ding, Xuanfeng [1 ]
机构
[1] William Beaumont Univ Hosp, Dept Radiat Oncol, Royal Oak, MI USA
[2] Union Hosp, Dept Radiat Oncol, Wuhan, Peoples R China
[3] Stanford Univ, Dept Radiat Oncol, Stanford, CA 94305 USA
关键词
Proton Arc therapy; quality assurance;
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
1971
引用
收藏
页码:S4852 / S4854
页数:4
相关论文
共 50 条
  • [1] The first investigation of the dosimetric perturbations from the spot position errors in spot-scanning arc therapy (SPArc)
    Liu, Peilin
    Zhao, Lewei
    Liu, Gang
    Cong, Xiaoda
    Li, Xiaoqiang
    Ding, Xuanfeng
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (13):
  • [2] Evaluating the Impact of Spot Position Errors on Dose Distribution: A Comparison between Spot-Scanning Arc Therapy (SPArc) and Intensity-Modulated Proton Therapy (IMPT)
    Liu, P.
    Zhao, L.
    Liu, G.
    Cong, X.
    Li, X.
    Ding, X.
    MEDICAL PHYSICS, 2024, 51 (10) : 7785 - 7785
  • [3] An investigation of dosimetric impact from gantry rotational errors in the SPArc therapy
    Liu, Peilin
    Cong, Xiaoda
    Liu, Gang
    Li, Xiaoqiang
    Zhao, Lewei
    Ding, Xuanfeng
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S4857 - S4860
  • [4] Investigate the Delivery Efficiency and Accuracy of Spot-Scanning Proton Arc (SPArc) in Comparison with Conventional IMPT, Automatic Step-And-Shoot Multifield IMPT
    Zhao, L.
    Liu, G.
    Yan, D.
    Li, X.
    Ding, X.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [5] Is Spot-Scanning Proton Beam Therapy Ready for the Single Target Brain Stereotactic Radiosurgery? A Dosimetric Comparison Study Among VMAT, SPArc and IMPT
    Chang, S.
    Liu, G.
    Chinnaiyan, P.
    Zhao, L.
    Zheng, W.
    Yan, D.
    Grills, I.
    Stevens, C.
    Kabolizadeh, P.
    Li, X.
    Ding, X.
    MEDICAL PHYSICS, 2020, 47 (06) : E468 - E468
  • [6] Dosimetric impact of systematic spot position errors in spot scanning proton therapy of head and neck tumor
    Yasui, Keisuke
    Omi, Yuta
    Shimomura, Akira
    Muramatsu, Rie
    Iwata, Hiromitsu
    Ogino, Hiroyuki
    Hayashi, Naoki
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2023, 19 (SUPPL 1) : S228 - S233
  • [7] Dosimetric Impact of Spot Size and Beam Aperture in IMPT: A Pediatric Chestwall Ewing Sarcoma Perspective
    Su, Z.
    Indelicato, D. J.
    Vega, R. Mailhot
    Bradley, J. A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E375 - E375
  • [8] Reducing Toxicity From Oropharyngeal Cancer Therapy With IMPT: A Dosimetric Analysis
    Yeung, D.
    Dagan, R.
    Ho, M.
    McKenzie, C.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S512 - S512
  • [9] Investigating the Influence of Spot Error on Plan Quality: A Comparative Study of Spot-Scanning Arc Therapy (SPArc) and Intensity-Modulated Proton Therapy (IMPT)
    Liu, P.
    Zhao, L.
    Liu, G.
    Cong, X.
    Li, X.
    Ding, X.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2024, 120 (02): : E158 - E158
  • [10] Effectiveness of Using Spot-ScanningProton Arc (SPArc) Therapy to Mitigate the Motion Interplay Effect in Lung Stereotactic Bodyradiotherapy (SBRT): A Quantitative Comparison Study between IMPT Vs SPArc Based a Digital Phantom
    Liu, G.
    Li, X.
    Qin, A.
    Grills, I.
    Stevens, C.
    Yan, D.
    Zhang, S.
    Li, Q.
    Quan, H.
    Kabolizadeh, P.
    Ding, X.
    MEDICAL PHYSICS, 2019, 46 (06) : E249 - E249