Intraindividual Comparison of Ultrahigh-Spatial-Resolution Photon-Counting Detector CT and Energy-Integrating Detector CT for Coronary Stenosis Measurement

被引:6
|
作者
Vecsey-Nagy, Milan [1 ,2 ]
Tremamunno, Giuseppe [1 ,3 ]
Schoepf, U. Joseph [1 ]
Gnasso, Chiara [1 ,4 ]
Zsarnoczay, Emese [1 ,5 ]
Fink, Nicola [1 ,6 ]
Kravchenko, Dmitrij [1 ,7 ]
Halfmann, Moritz C. [8 ]
Laux, Gerald S. [9 ]
O'Doherty, Jim [1 ,10 ]
Szilveszter, Balint [2 ]
Maurovich-Horvat, Pal [5 ]
Kabakus, Ismail Mikdat [1 ]
Suranyi, Pal Spruill [1 ]
Varga-Szemes, Akos [1 ]
Emrich, Tilman [1 ,8 ]
机构
[1] Med Univ South Carolina, Dept Radiol & Radiol Sci, Charleston, SC USA
[2] Semmelweis Univ, Heart & Vasc Ctr, Budapest, Hungary
[3] Sapienza Univ Rome, Dept Med Surg Sci & Translat Med, Radiol Unit, Rome, Italy
[4] IRCCS San Raffaele Sci Inst, Expt Imaging Ctr, Milan, Italy
[5] Semmelweis Univ, Med Imaging Ctr, Dept Radiol, MTA SE Cardiovasc Imaging Res Grp, Budapest, Hungary
[6] Ludwig Maximilians Univ Munchen, Univ Hosp, Dept Radiol, Munich, Germany
[7] Univ Hosp Bonn, Dept Diagnost & Intervent Radiol, Bonn, Germany
[8] Johannes Gutenberg Univ Mainz, Univ Med Ctr, Dept Diagnost & Intervent Radiol, Mainz, Germany
[9] Johannes Gutenberg Univ Mainz, Univ Med Ctr, Dept Cardiol, Mainz, Germany
[10] Siemens Med Solut, Malvern, PA USA
关键词
computed tomography angiography; coronary angiography; coronary artery disease; coronary stenosis; COMPUTED-TOMOGRAPHY ANGIOGRAPHY; QUANTIFICATION; PREDICTORS;
D O I
10.1161/CIRCIMAGING.124.017112
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: A recent simulation study proposed that stenosis measurements on coronary computed tomography (CT) angiography are influenced by the improved spatial resolution of photon-counting detector (PCD)-CT. The aim of the current study was to evaluate the impact of ultrahigh-spatial-resolution (UHR) on coronary stenosis measurements and Coronary Artery Disease Reporting and Data System (CAD-RADS) reclassification rates in patients undergoing coronary CT angiography on both PCD-CT and energy-integrating detector (EID)-CT and to compare measurements against quantitative coronary angiography. METHODS: Patients with coronary calcification on EID-CT (collimation, 192x0.6 mm) were prospectively enrolled for a research coronary CT angiography with UHR PCD-CT (collimation, 120x0.2 mm) within 30 days (between April 1, 2023 and January 31, 2024). PCD-CT was acquired with the same or lower CT dose index and equivalent contrast media volume as EID-CT. Percentage diameter stenosis (PDS) for calcified, partially calcified, and noncalcified lesions were compared between scanners. Patient-level reclassification rates for CAD-RADS were evaluated. The accuracy of PDS measurements was validated against quantitative coronary angiography in patients who underwent invasive coronary angiography. RESULTS: In total, PDS of 278 plaques were quantified in 49 patients (calcified, 202; partially calcified, 51; noncalcified, 25). PCD-CT-based PDS values were lower than EID-CT measurements for calcified (45.1 +/- 20.7 versus 54.6 +/- 19.2%; P<0.001) and partially calcified plaques (44.3 +/- 19.6 versus 54.9 +/- 20.0%; P<0.001), without significant differences for noncalcified lesions (39.1 +/- 15.2 versus 39.0 +/- 16.0%; P=0.98). The reduction in stenosis degrees led to a 49.0% (24/49) reclassification rate to a lower CAD-RADS with PCD-CT. In a subset of 12 patients with 56 lesions, UHR-based PDS values showed higher agreement with quantitative coronary angiography (mean difference, 7.3%; limits of agreement, -10.7%/25.2%) than EID-CT measurements (mean difference, 17.4%; limits of agreement, -6.9%/41.7%). CONCLUSIONS: Compared with conventional EID-CT, UHR PCD-CT results in lower PDS values and more accurate stenosis measurements in coronary plaques with calcified components and leads to a substantial Coronary Artery Disease Reporting and Data System reclassification rate in 49.0% of patients.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Coronary Plaque Quantification with Ultrahigh-Spatial-Resolution Photon-counting Detector CT: Intraindividual Comparison with Energy-integrating Detector CT
    Vecsey-Nagy, Milan
    Tremamunno, Giuseppe
    Schoepf, U. Joseph
    Gnasso, Chiara
    Zsarnoczay, Emese
    Fink, Nicola
    Kravchenko, Dmitrij
    Halfmann, Moritz C.
    O'Doherty, Jim
    Szilveszter, Balint
    Maurovich-Horvat, Pal
    Kabakus, Ismail Mikdat
    Suranyi, Pal Spruill
    Emrich, Tilman
    Varga-Szemes, Akos
    RADIOLOGY, 2025, 314 (03)
  • [2] Ultrahigh-Spatial-Resolution Photon-counting Detector CT Angiography of Coronary Artery Disease for Stenosis Assessment
    Halfmann, Moritz C.
    Bockius, Stefanie
    Emrich, Tilman
    Hell, Michaela
    Schoepf, U. Joseph
    Laux, Gerald S.
    Kavermann, Larissa
    Graafen, Dirk
    Gori, Tomasso
    Yang, Yang
    Kloeckner, Roman
    Maurovich-Horvat, Pal
    Ricke, Jens
    Mueller, Lukas
    Varga-Szemes, Akos
    Fink, Nicola
    RADIOLOGY, 2024, 310 (02)
  • [3] Comparison of Photon-counting Detector and Energy-integrating Detector CT for Visual Estimation of Coronary Percent Luminal Stenosis
    Mccollough, Cynthia H.
    Rajiah, Prabhakar
    Bois, John P.
    Winfree, Tim N.
    Carter, Rickey E.
    Rajendran, Kishore
    Williamson, Eric E.
    Thorne, Jamison E.
    Leng, Shuai
    RADIOLOGY, 2023, 309 (03)
  • [4] Infrapopliteal Segments on Lower Extremity CTA: Prospective Intraindividual Comparison of Energy-Integrating Detector CT and Photon-Counting Detector CT
    Yalon, Mariana
    Inoue, Akitoshi
    Thorne, Jamison E.
    Lee, Yong S.
    Johnson, Matthew P.
    Esquivel, Andrea
    Leng, Shuai
    McCollough, Cynthia H.
    Fletcher, Joel G.
    Rajiah, Prabhakar Shantha
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2024, 222 (03)
  • [5] Intra-individual comparison of coronary artery stenosis measurements between energy-integrating detector CT and photon-counting detector CT
    Wolf, Elias V.
    Gnasso, Chiara
    Schoepf, U. Joseph
    Halfmann, Moritz C.
    O'Doherty, Jim
    Zsarnoczay, Emese
    Varga-Szemes, Akos
    Emrich, Tilman
    Fink, Nicola
    IMAGING, 2023, 15 (02): : 61 - 68
  • [6] Coronary CT angiography-based FFR with ultrahigh-resolution photon-counting detector CT: Intra-individual comparison to energy-integrating detector CT
    Vecsey-Nagy, Milan
    Tremamunno, Giuseppe
    Schoepf, U. Joseph
    Gnasso, Chiara
    Zsarnoczay, Emese
    Fink, Nicola
    Kravchenko, Dmitrij
    Hagar, Muhammad Taha
    Halfmann, Moritz C.
    Jokkel, Zsofia
    O'Doherty, Jim
    Szilveszter, Balint
    Maurovich-Horvat, Pal
    Suranyi, Pal Spruill
    Varga-Szemes, Akos
    Emrich, Tilman
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 181
  • [7] Giant Thrombus in a Coronary Artery Bypass Graft: Comparison of Photon-counting Detector CT and Energy-integrating Detector CT
    Zhang, Huixin
    Jin, Dongsheng
    RADIOLOGY, 2024, 313 (03)
  • [8] Intraindividual reproducibility of myocardial radiomic features between energy-integrating detector and photon-counting detector CT angiography
    Tremamunno, Giuseppe
    Varga-Szemes, Akos
    Schoepf, U. Joseph
    Laghi, Andrea
    Zsarnoczay, Emese
    Fink, Nicola
    Aquino, Gilberto J.
    O'Doherty, Jim
    Emrich, Tilman
    Vecsey-Nagy, Milan
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2024, 8 (01)
  • [9] Optimizing Chest CT With Photon-counting Detector Technology: Comparison to Established Energy-integrating Detector CT Protocols
    Alarab, N.
    Guo, J.
    Atha, J.
    Sieren, J. C.
    Puliyakote, A. S. Kizhakke
    Hoffman, E. A.
    Abadi, E.
    Fain, S. B.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2024, 209
  • [10] Low-dose CT of the abdomen: Initial experience on a novel photon-counting detector CT and comparison with energy-integrating detector CT
    Decker, Josua A.
    Bette, Stefanie
    Lubina, Nora
    Rippel, Katharina
    Braun, Franziska
    Risch, Franka
    Wollny, Claudia
    Scheurig-Muenkler, Christian
    Kroencke, Thomas J.
    Schwarz, Florian
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 148