Usefulness of percutaneous transluminal coronary balloon angioplasty for coronary artery stenosis after surgery for CHD

被引:0
|
作者
Tsuda, Etsuko [1 ]
Kitano, Masataka [2 ]
Iwasa, Toru [1 ]
Sakaguchi, Heima [1 ]
Ohuchi, Hideo [1 ]
Kurosaki, Kenichi [1 ]
机构
[1] Natl Cerebral & Cardiovasc Ctr, Dept Pediat Cardiol, Suita, Japan
[2] Okinawa Nanbu Childrens Med Ctr, Dept Pediat Cardiol, Okinawa, Japan
关键词
Percutaneous transluminal coronary balloon angioplasty; coronary artery stenosis; percutaneous coronary intervention; SWITCH OPERATION; TRANSPOSITION;
D O I
10.1017/S1047951124026556
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Coronary artery involvements occur rarely both during cardiac repair and in the late period after surgery, and it may result in myocardial ischaemia and infarction. We present six cases who underwent percutaneous transluminal coronary balloon angioplasty for coronary artery stenosis in the late period after surgery. The patients included four boys and two girls. Post-operative states involving anomalous origin of the left coronary artery from the pulmonary artery and d-transposition of the great arteries were observed in two patients each. Two patients with univentricular heart had coronary artery injuries during surgery. The age at the angioplasty ranged from 1 month to 14 years, with a median of 3 years. The interval from the operation to angioplasty ranged from 37 days to 14 years (median 8 months). The interval from the angioplasty to follow-up coronary angiography ranged from 2 months to 14 years (median 11 months). The follow-up period ranged from 2 months to 20 years (median 8 years). One patient underwent a stent implantation because of post-procedure recoil. Coronary artery stenosis improved immediately after procedure in the six patients without complication, and restenosis occurred post-procedure in one patient. Five patients had no cardiac events. Although the angioplasty's initial effect may not be dramatic, it can improve late after the procedure. It was considered that the optimal balloon-reference vessel ratio to obtain a minimal effective lumen diameter was about 1.0. Angioplasty post-surgery for CHD in children was feasible and without complications.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Usefulness of Percutaneous Transluminal Coronary Balloon Angioplasty for the Left Coronary Artery Stenosis 10 Years More Than After Arterial Switch Operation
    Tsujii, Nobuyuki
    Tsuda, Etsuko
    Asaumi, Yasuhide
    Yamada, Osamu
    PEDIATRIC CARDIOLOGY, 2016, 37 (04) : 751 - 755
  • [2] Usefulness of Percutaneous Transluminal Coronary Balloon Angioplasty for the Left Coronary Artery Stenosis 10 Years More Than After Arterial Switch Operation
    Nobuyuki Tsujii
    Etsuko Tsuda
    Yasuhide Asaumi
    Osamu Yamada
    Pediatric Cardiology, 2016, 37 : 751 - 755
  • [3] Internuclear ophthalmoplegia after coronary artery catheterization and percutaneous transluminal coronary balloon angioplasty
    Eggenberger, ER
    Desai, NP
    Kaufman, DI
    Pless, M
    JOURNAL OF NEURO-OPHTHALMOLOGY, 2000, 20 (02) : 123 - 126
  • [4] IATROGENIC CORONARY STENOSIS AFTER PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY
    QUIRET, JC
    REMOND, A
    JARRY, G
    AVINEE, P
    CAZE, F
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 1990, 83 (03): : 385 - 391
  • [5] Coronary artery vasomotion after percutaneous transluminal coronary angioplasty
    Misra, VK
    Agirbasli, M
    Fischell, TA
    CLINICAL CARDIOLOGY, 1997, 20 (11) : 915 - 922
  • [6] Emergency coronary artery bypass surgery after failed percutaneous transluminal coronary angioplasty
    Andreasen, JJ
    Mortensen, PE
    Andersen, LI
    Arendrup, HC
    Ilkjær, LB
    Kjoller, M
    Thayssen, P
    SCANDINAVIAN CARDIOVASCULAR JOURNAL, 2000, 34 (03) : 242 - 246
  • [7] Acute occlusion of the coronary artery after transluminal balloon coronary angioplasty
    Kardiologicheskij NTs RAMN, Moscow, Russia
    Vestn Rentgenol Radiol, 2 ([d]10-14):
  • [8] PREDICTORS OF CORONARY-ARTERY RESTENOSIS IN PATIENTS WITH CORONARY HEART-DISEASE (CHD) AFTER TRANSLUMINAL BALLOON CORONARY ANGIOPLASTY
    SAVCHENKO, AP
    SAED, IR
    MATCHIN, YG
    SMIRNOV, AA
    LYAKISHEV, AA
    TERAPEVTICHESKII ARKHIV, 1995, 67 (04) : 35 - 39
  • [9] USEFULNESS OF PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY AFTER NEW DEVICE CORONARY INTERVENTIONS
    SAFIAN, RD
    FREED, M
    LICHTENBERG, A
    MAY, MA
    STRZELECKI, M
    GRINES, CL
    PAVLIDES, G
    SCHREIBER, TL
    ONEILL, WW
    AMERICAN JOURNAL OF CARDIOLOGY, 1994, 73 (09): : 642 - 646
  • [10] PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY IN AN INFANT WITH CORONARY-ARTERY STENOSIS AFTER ARTERIAL SWITCH OPERATION
    ALLADA, V
    JARMAKANI, JM
    YEATMAN, L
    AMERICAN HEART JOURNAL, 1991, 122 (05) : 1464 - 1465