A non-contact calibration method of workpiece coordinate system for aero-engine blade-robotic grinding system

被引:0
|
作者
Chen, Ziyang [1 ]
Cai, Zhenhua [1 ]
Chen, Tingyang [2 ]
Deng, Chunming [3 ]
Niu, Shaopeng [3 ]
Wang, Chao [3 ]
Qu, Dongbo [1 ]
Ma, Zhenhua [1 ]
Hu, Yu [1 ]
机构
[1] Wuhan Univ Technol, Sch Automat, 122 Luoshi Rd, Wuhan 430070, Hubei, Peoples R China
[2] Wuhan Univ Technol, State Key Lab Silicate Mat Architectures, Wuhan, Peoples R China
[3] Guangdong Acad Sci, Inst New Mat, Guangzhou, Peoples R China
关键词
Workpiece calibration; aero-engine blade; robot grinding; hand-eye calibration; point cloud registration;
D O I
10.1177/09544054251315506
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Mounting error of the blade is an important factor that affects the grinding quality in aero-engine blade-robotic grinding system. In order to compensate for the mounting error, it is necessary to calibrate the pose of the workpiece coordinate system. However, most of the current workpiece calibration methods cannot meet the high accuracy requirements in the scenario of aero-engine blade grinding. Therefore, this paper proposes a new non-contact calibration method of workpiece coordinate system using scanner measurement, to solve the workpiece calibration problem in aero-engine blade-robotic grinding system. The method first calibrates the scanner based on the criterion sphere hand-eye calibration method and employs the Random Sample Consensus (RANSAC) algorithm to ensure the accuracy of the fitted sphere center coordinates. Then, the point cloud registration algorithms are used to align the scanned point cloud of the blade with the model point cloud. Finally, the space transformation matrix between the workpiece coordinate system and the base coordinate system is obtained through matrix calculation, achieving the accurate calibration of the workpiece coordinate system. The experimental validation of the proposed calibration method in this paper can maintain tiny and acceptable errors for grinding applications. Specifically, the hand-eye calibration error is less than 0.2 mm, and the point cloud registration error is less than 0.06 mm. Moreover, the calibrated blade exhibits excellent machining consistency after grinding, which can perfectly meet the requirements of actual machining accuracy.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] A vision-based calibration method for aero-engine blade-robotic grinding system
    Chen, Chen
    Cai, Zhenhua
    Chen, Tingyang
    Li, Zifan
    Yang, Fan
    Liang, Xufeng
    INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2023, 125 (5-6): : 2195 - 2209
  • [2] A vision-based calibration method for aero-engine blade-robotic grinding system
    Chen Chen
    Zhenhua Cai
    Tingyang Chen
    Zifan Li
    Fan Yang
    Xufeng Liang
    The International Journal of Advanced Manufacturing Technology, 2023, 125 : 2195 - 2209
  • [3] Belt grinding process with force control system for blade of aero-engine
    Duan, Jihao
    Zhang, Youmin
    Shi, Yaoyao
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART B-JOURNAL OF ENGINEERING MANUFACTURE, 2016, 230 (05) : 858 - 869
  • [4] Advances in the application of non-contact temperature measurement technology for aero-engine blade
    Cui, Ying
    Qiu, Kongxin
    Gao, Shan
    Chen, Liwei
    Jiang, Jing
    Niu, Yi
    Wang, Chao
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2024, 95 (08):
  • [5] Combined non-contact coordinate measurement system and calibration method
    Fan, Yiyan
    Zhao, Bin
    OPTICS AND LASER TECHNOLOGY, 2015, 70 : 100 - 105
  • [6] Contact Characteristics and Material Removal Mechanism of Abrasive Disc Grinding of Aero-engine Blade
    Duan J.
    An J.
    Wu Z.
    Huai W.
    Gao F.
    Jixie Gongcheng Xuebao/Journal of Mechanical Engineering, 2023, 59 (17): : 349 - 360
  • [7] Research on Contact Characteristics of Belt Grinding of Aero-engine Blade Based on Compliance Adjustment of Contact Wheel
    Jihao D.
    Zewei Z.
    Jiale A.
    Feng G.
    Yan L.
    Wenbo H.
    Jixie Gongcheng Xuebao/Journal of Mechanical Engineering, 2023, 59 (15): : 354 - 365
  • [8] A new calibration method for a dynamic coordinate system in a robotic blade grinding and polishing system based on the six-point limit principle
    Zhu, Guang
    Cai, Ming
    Wang, Zhengjia
    Li, Lun
    Zhao, Jibin
    Zhou, Bo
    ROBOTICS AND COMPUTER-INTEGRATED MANUFACTURING, 2023, 83
  • [9] Research on Partition Segment Grinding Path Method of Aero-Engine Blade Based on Robot Group
    Qiu, Lei
    Ji, Shiming
    Zeng, Xi
    Jin, Mingsheng
    Li, Zhuo
    Ge, Man
    IEEE SENSORS JOURNAL, 2020, 20 (20) : 11836 - 11848
  • [10] The Dynamic Digital Radiography System Design and Data Calibration Method for Monitoring the Running Aero-engine
    Chang, Ming
    Xiao, Yongshun
    Chen, Zhiqiang
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,