Development and Validation of Derivatization Method for Simultaneous Quantitation of Asteracantha longifolia (L.) Nees Phytoconstituents by Liquid Chromatography-Electrospray Ionization-Mass Spectrometry/Mass Spectrometry

被引:1
|
作者
Raval, Sadanand Eknath [1 ]
Sapale, Seema R. [1 ]
Vaidya, Vikas V. [2 ]
Gosar, Amit [3 ]
机构
[1] Kirti M Doongursee Coll, Dept Chem, Mumbai, Maharashtra, India
[2] Royal Coll Arts Sci & Commerce, Dept Chem, Thana, India
[3] Indoco Remedies, Res & Dev Ctr, Navi Mumbai, Maharashtra, India
关键词
beta-sitosterol; betulin; lupeol; p-toluenesulfonyl isocyanate; stigmasterol; GAS-CHROMATOGRAPHY; PRECOLUMN DERIVATIZATION; SILYLATION; BETULIN; APCI;
D O I
10.4103/ajprhc.ajprhc_132_23
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Background: Betulin, lupeol, stigmasterol, and beta-sitosterol are the active phytoconstituents accountable for the practical application of Asteracantha longifolia (L.) Nees in ayurvedic treatments as antitumor, hypoglycemic, aphrodisiac, antibacterial, free radical scavenging, lipid peroxidation, and hepatoprotective agent. As an essential medicinal plant in modern and traditional medicine, regularly checking raw material's quality attributes and quantifying the phytoconstituents is indispensable. Aim: The aim of this study was to optimize derivatization conditions of these four essential phytoconstituents with p-toluenesulfonyl isocyanate (PTSI) reagent and the development of a liquid chromatography-electrospray ionization (ESI)-mass spectrometry (MS)/MS method that aids in the simultaneous detection of these four phytoconstituents. Objective: Thus, derivatization enhances sensitivity for detection in the negative mode with an electron spray ionization source and tandem mass spectroscopy. Further, the sensitive and rapid analytical method for simultaneous quantitation of betulin, lupeol, stigmasterol, and beta-sitosterol is subsequently validated in line with the guidelines by ICH and used to quantify the phytoconstituents in two over-the-counter herbal formulations and one plant extract isolated at laboratory scale under batch analysis. Materials and Methods: PTSI reagent of purity <98% procured from TCI and other chromatography reagents of MS grade were utilized in the optimization of an analytical method. Results: The developed LC-ESI-MS/MS-based method demonstrated specificity for the targeted phytoconstituents, with LOD and LOQ values of < 0.13 ng/mL and 0.4 ng/mL, respectively. Linearity was established with a correlation coefficient >= 0.998 over a concentration range of 0.2 ng/mL to 6 ng/mL. Precision, expressed as %RSD for peak response, was <= 5%. The method showed satisfactory recovery for betulin (98.5%-108.3%), lupeol (95.0%-109.3%), stigmasterol (101.9%-117.0%), and beta-sitosterol (99.1%-116.2%). Conclusion: The reagent PTSI reacts rapidly and forms stable derivatives. The derivatization of active phytoconstituents betulin, lupeol, stigmasterol, and beta-sitosterol has enhanced the detection sensitivity of the analytical method.
引用
收藏
页码:74 / 83
页数:10
相关论文
共 50 条
  • [1] Liquid chromatography-electrospray ionization mass spectrometry for the simultaneous quantitation of collagen and elastin crosslinks
    Naffa, Rafea
    Holmes, Geoff
    Ahn, Meekyung
    Harding, David
    Norris, Gillian
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1478 : 60 - 67
  • [2] Detection and quantitation of eicosanoids via high performance liquid chromatography-electrospray ionization-mass spectrometry
    Deems, Raymond
    Buczynski, Matthew W.
    Bowers-Gentry, Rebecca
    Harkewicz, Richard
    Dennis, Edward A.
    LIPIDOMICS AND BIOACTIVE LIPIDS: MASS-SPECTROMETRY-BASED LIPID ANALYSIS, 2007, 432 : 59 - 82
  • [3] Development of sensitive derivatization method for aldosterone in liquid chromatography-electrospray ionization tandem mass spectrometry of corticosteroids
    Yamashita, Kouwa
    Okuyama, Mitsunobu
    Nakagawa, Risa
    Honma, Seijiro
    Satoh, Fumitoshi
    Morimoto, Ryo
    Ito, Sadayoshi
    Takahashi, Madoka
    Numazawa, Mitsuteru
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1200 (02) : 114 - 121
  • [4] Derivatization for liquid chromatography-electrospray ionization-mass spectrometry analysis of small-molecular weight compounds
    Zhang, Tian-Yi
    Li, Sha
    Zhu, Quan-Fei
    Wang, Qing
    Hussain, Dilshad
    Feng, Yu-Qi
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2019, 119
  • [5] Determination of berberine in human plasma by liquid chromatography-electrospray ionization-mass spectrometry
    Hua, Wenyan
    Ding, Li
    Chen, Yan
    Gong, Bin
    He, Jianchang
    Xu, Guili
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 44 (04) : 931 - 937
  • [6] Determination of palonosetron in human plasma by liquid chromatography-electrospray ionization-mass spectrometry
    Ding, Li
    Chen, Yan
    Yang, Lin
    Wen, Aidong
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 44 (02) : 575 - 580
  • [7] Determination of voriconazole in aqueous humor by liquid chromatography-electrospray ionization-mass spectrometry
    Zhou, L
    Glickman, RD
    Chen, N
    Sponsel, WE
    Graybill, JR
    Lam, KW
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 776 (02): : 213 - 220
  • [8] Liquid chromatography-electrospray ionization-mass spectrometry: the future of DNA adduct detection
    Singh, R
    Farmer, PB
    CARCINOGENESIS, 2006, 27 (02) : 178 - 196
  • [9] A Validated Liquid Chromatography-Electrospray Ionization-Mass Spectrometry Method for Quantification of Spilanthol in Spilanthes acmella (L.) Murr.
    Bae, Stacy S.
    Ehrmann, Brandie M.
    Ettefagh, Keivan A.
    Cech, Nadja B.
    PHYTOCHEMICAL ANALYSIS, 2010, 21 (05) : 438 - 443
  • [10] Quantitation of salbutamol in human urine by liquid chromatography-electrospray ionization mass spectrometry
    Zhang, JL
    Xu, YX
    Di, X
    Wu, MT
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 831 (1-2): : 328 - 332