Thermal analysis of a main compression intercooling supercritical CO2 cycle cascaded with flash tank enhanced compression-absorption refrigeration cycle

被引:2
|
作者
Khan, Tausif Elahi [1 ]
Zaman, Masruf [1 ]
Ehsan, Mmonjurul [1 ]
Khan, Yasin [1 ]
机构
[1] Islamic Univ Technol IUT, Dept Mech & Prod Engn, Board Bazar 1704, Gazipur, Bangladesh
关键词
Supercritical CO 2; Cascade refrigeration; Flash tank; Compression-absorption; Main compression brayton; Thermal analysis; BRAYTON CYCLE; INTEGRATION; ENERGY;
D O I
10.1016/j.ecmx.2024.100868
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study develops a unique electric power generation and refrigeration system that integrating two cascade compression-absorption refrigeration (CCAR) sub-systems as heat recovery systems for the recompression with main compression intercooling supercritical CO2 Brayton (RMCIB) cycle. Two heat recovery systems utilize heat waste from the topping power cycle's pre-cooler and inter-cooler to create cooling load, enhancing overall system performance. In order to investigate the integrated system's thermal performance, comprehensive parametric analyses are conducted in Python programming language under various boundary scenarios; such as temperature at turbine's entrance, temperature at compressor's entrance, minimum pressure, intermediate pressure, pressure ratio, evaporator temperature and pinch temperature at generators' hot and cold ends. The results indicate that turbine inlet temperature (TIT) significantly increases thermal efficiency, while compressor inlet temperature (CIT) adversely affects system performance. Besides, exergy destruction occurring throughout the components of the proposed system is analyzed. Thermodynamic optimization reveals thermal and exergy efficiencies of 54.23 % and 65.34 %, with the RMCIB subsystem's energy efficiency improving by 15.38 % and 2nd law efficiency by 3.35 % through CCAR integration. Under optimal conditions, the system produces 64 MW net work and 12 MW cooling load from 100 MW of input heat. Most exergy destruction occurs in the RMCIB subsystem, with heaters and recuperators contributing 10 % and 11.5 % of losses, respectively.
引用
收藏
页数:21
相关论文
共 50 条
  • [1] Thermodynamic analysis of double-compression flash intercooling transcritical CO2 refrigeration cycle
    Zhang, Zhenying
    Wang, Hongli
    Tian, Lili
    Huang, Chunsong
    JOURNAL OF SUPERCRITICAL FLUIDS, 2016, 109 : 100 - 108
  • [2] Thermodynamic study of main compression intercooling effects on supercritical CO2 recompression Brayton cycle
    Ma, Yuegeng
    Liu, Ming
    Yan, Junjie
    Liu, Jiping
    ENERGY, 2017, 140 : 746 - 756
  • [3] Exergy analysis of vapour compression-absorption two-stage refrigeration cycle
    Ozturk, Ilhan Tekin
    Cimsit, Canan
    INTERNATIONAL JOURNAL OF EXERGY, 2021, 35 (02) : 210 - 221
  • [4] Investigation of an ejector-cascaded vapor compression-absorption refrigeration cycle powered by linear fresnel and organic rankine cycle
    Askari, Ighball Baniasad
    Ghazizade-Ahsaee, Hossein
    Kasaeian, Alibakhsh
    ENVIRONMENT DEVELOPMENT AND SUSTAINABILITY, 2023, 25 (09) : 9439 - 9484
  • [5] Performance evaluation of supercritical CO2 Brayton cycle with two-stage compression and intercooling
    Jiang, Jiahui
    Yu, Yongqiang
    Zhao, Yuanyang
    Liu, Guangbin
    Yang, Qichao
    Liu, Yunxia
    Li, Liansheng
    CASE STUDIES IN THERMAL ENGINEERING, 2024, 64
  • [6] Thermodynamic performance analysis of a vapor compression-absorption cascaded refrigeration system
    Jain, Vaibhav
    Kachhwaha, S. S.
    Sachdeva, Gulshan
    ENERGY CONVERSION AND MANAGEMENT, 2013, 75 : 685 - 700
  • [7] Study on characteristics of wet compression-absorption refrigeration cycle with CO2-ionic liquid mixture
    Li, Kun
    Wu, Weidong
    Liang, Kunfeng
    Zhang, Hua
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2024, 154
  • [8] Thermal analysis of a novel configuration of double effect absorption system cascaded with ejector and injection enhanced compression refrigeration cycle
    Siddique, Sefat Mahmud
    Uzzaman, M. Muhtasim
    Ehsan, M. Monjurul
    Khan, Yasin
    ENERGY CONVERSION AND MANAGEMENT, 2025, 326
  • [9] Parametric analysis and optimization of a novel cascade compression-absorption refrigeration system integrated with a flash tank and a reheater
    Faruque, Md Walid
    Khan, Yasin
    Nabil, Mahdi Hafiz
    Ehsan, M. Monjurul
    RESULTS IN ENGINEERING, 2023, 17
  • [10] Optimization of waste heat based organic Rankine cycle powered cascaded vapor compression-absorption refrigeration system
    Patel, Bhavesh
    Desai, Nishith B.
    Kachhwaha, Surendra Singh
    ENERGY CONVERSION AND MANAGEMENT, 2017, 154 : 576 - 590