Analysis of Influence of Grid-Following and Grid-Forming Static Var Generators on High-Frequency Resonance in Doubly Fed Induction Generator-Based Wind Farms

被引:1
|
作者
Sun, Yong [1 ]
Wu, Hongbin [2 ]
Song, Xiaozhe [3 ]
Zhang, Haifeng [4 ]
Zhang, Yifu [4 ]
Chen, Jikai [2 ]
Liu, Hongpeng [2 ]
机构
[1] Jilin Elect Power Co Ltd, Power Econ Res Inst, Changchun 130021, Peoples R China
[2] Northeast Elect Power Univ, Sch Elect Engn, Jilin 132012, Peoples R China
[3] State Grid Jilin Elect Power Co Ltd, Changchun 130021, Peoples R China
[4] State Grid Jilin Elect Power Res Inst, Changchun 130021, Peoples R China
关键词
DFIG-based wind farm; GFM control; high-frequency resonance; static var generator; sequential impedance modeling; VOLTAGE-SOURCE; STABILITY; HVDC;
D O I
10.3390/electronics13193879
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In Doubly Fed Induction Generator (DFIG)-based wind farms with Static Var Generators (SVGs), high-frequency resonance will be more like to occur when an unloaded cable is put into operation, which will threaten the stable operation of the wind farm. To address this issue, the influence of power outer loops on the impedance of grid-connected inverters is considered. Based on harmonic linearization, theoretical models for the sequence impedances of DFIGs, Grid-following (GFL) SVGs, and Grid-forming (GFM) SVGs are established. The correctness of the three models is verified by impedance scanning using the frequency sweep method. Through a comparative analysis of these sequence impedances, it is found that unlike the GFM SVG (which exhibits inductive impedance), the GFL SVG exhibits capacitive impedance in the high-frequency band, which leads to negative damping characteristics in the high-frequency band for the wind farm system with the grid-following SVG; thereby, the risk of high-frequency resonance also increases accordingly. On the contrary, GFM control adopted by SVGs can effectively eliminate the negative damping region in the high-frequency band for wind farms to suppress high-frequency resonance. Meanwhile, for grid-forming SVGs, the parameter variations in power synchronous loops have no significant impact on the suppressing effect of high-frequency resonance for wind farms. Finally, an electromagnetic simulation model for a DFIG-based wind farm system with an SVG is established using the StarSim-HIL (hardware-in-the-loop) experiment platform, and the simulation results validate the correctness of the theoretical analysis.
引用
收藏
页数:21
相关论文
共 47 条
  • [1] Stability Comparison Between Grid-forming and Grid-following Based Wind Farms Integrated MMC-HVDC
    Pan, Rongcai
    Liu, Dong
    Liu, Shan
    Yang, Jie
    Kou, Longze
    Tang, Guangfu
    JOURNAL OF MODERN POWER SYSTEMS AND CLEAN ENERGY, 2023, 11 (04) : 1341 - 1355
  • [2] Stability Comparison Between Grid-forming and Grid-following Based Wind Farms Integrated MMC-HVDC
    Rongcai Pan
    Dong Liu
    Shan Liu
    Jie Yang
    Longze Kou
    Guangfu Tang
    Journal of Modern Power Systems and Clean Energy, 2023, 11 (04) : 1341 - 1355
  • [3] Analysis of broadband oscillation mechanisms in grid-forming and grid-following converters based on virtual synchronous generator
    Wang, Weiming
    Liu, Zhijian
    Lou, Jun
    Cheng, Cheng
    Song, Qi
    Shi, Yaoting
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2025, 19 (01)
  • [4] Frequency-Voltage Active Support Strategy for Hybrid Wind Farms Based on Grid-Following and Grid-Forming Hierarchical Subgroup Control
    Zhao, Haiyu
    Zong, Qihang
    Zhou, Hongyu
    Yao, Wei
    Sun, Kangyi
    Zhou, Yuqing
    Wen, Jinyu
    CSEE JOURNAL OF POWER AND ENERGY SYSTEMS, 2025, 11 (01): : 65 - 77
  • [5] Grid-forming control of doubly-fed induction generators based on the rotor flux orientation
    Martinez, Jesus Castro
    Amenedo, Jose Luis Rodriguez
    Gomez, Santiago Arnaltes
    Alonso-Martinez, Jaime
    RENEWABLE ENERGY, 2023, 207 : 162 - 176
  • [6] Damping Analysis and Torque Oscillation Suppression of Power Synchronized Grid-forming Doubly-fed Induction Generator in Weak Grid
    Xie Z.
    Gao X.
    Zhang X.
    Zhang X.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2023, 47 (11): : 29 - 38
  • [7] Controller saturation nonlinearity in doubly fed induction generator-based wind turbines under unbalanced grid conditions
    Li, Zhen
    Wong, Siu-Chung
    Tse, Chi K.
    Liu, Xiangdong
    INTERNATIONAL JOURNAL OF CIRCUIT THEORY AND APPLICATIONS, 2016, 44 (08) : 1602 - 1619
  • [8] Grid Ancillary Services From Doubly Fed Induction Generator-Based Wind Energy Conversion System: A Review
    Debouza, Mahdi
    Al-Durra, Ahmed
    IEEE ACCESS, 2019, 7 : 7067 - 7081
  • [9] A Comparative Sub-synchronous Resonance Analysis of Grid-connected Doubly Fed Induction Generator Based and Permanent Magnet Synchronous Generator Based Wind Farms
    Su, Junlin
    Shi, Libao
    Yao, Liangzhong
    Ni, Yixin
    Guo, Zijian
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2015, 43 (07) : 792 - 809
  • [10] An improved predictive control for parallel grid-connected doubly fed induction generator-based wind systems under unbalanced grid conditions
    Ghodbane-Cherif, Meriem
    Skander-Mustapha, Sondes
    Slama-Belkhodja, Ilhem
    WIND ENGINEERING, 2019, 43 (04) : 377 - 391