Commissural Alignment in SAPIEN 3 Valves: Impact on Gradient and Mortality at Follow-Up

被引:0
|
作者
Unzue, Leire [1 ,2 ]
Anton, Belen Diaz [2 ,3 ]
Laderas, Adrian Pelaez [2 ,4 ,5 ]
Polo, Lorena Martin [2 ,6 ]
Vazquez, Jose Maria Castellano [2 ,6 ]
Rodrigo, Francisco Jose Rodriguez [2 ,6 ]
Jimenez, Francisco Javier Parra [2 ,6 ]
Fernandez-Friera, Leticia [2 ,3 ,4 ,6 ]
Mestre, Rodrigo Teijeiro [1 ,2 ]
Fernandez, Eulogio Garcia [1 ,2 ]
机构
[1] HM Hosp, HM CIEC MADRID Ctr Integral Enfermedades Cardiovas, Dept Cardiol Intervencionista, Madrid, Spain
[2] HM Hosp, Inst Invest Sanitaria, Madrid, Spain
[3] HM Hosp, HM CIEC MADRID Ctr Integral Enfermedades Cardiovas, Dept Imagen Cardiaca, Madrid, Spain
[4] Univ Camilo Jose Cela, Fac HM Ciencias Salud, Madrid, Spain
[5] Inst Salud Carlos III ISCIII, Ctr Invest Red Enfermedades Resp CIBERES, Madrid, Spain
[6] HM Hosp, HM CIEC MADRID Ctr Integral Enfermedades Cardiovas, Dept Cardiol, Madrid, Spain
关键词
commissural alignment; SAPIEN; 3; valves; TAVR; ACUTE CORONARY SYNDROME; AORTIC-VALVE; LEAFLET THROMBOSIS; IMPLANTATION; REPLACEMENT; PREDICTORS; OUTCOMES; ARTERY; TAVR;
D O I
10.1002/ccd.31418
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Commissural misalignment (CMA) has demonstrated to difficult future coronary access in self-expandable prosthesis and has been related with subclinical leaflet thrombosis and a potential increase in valve gradients and aortic regurgitation at follow-up. Aims: The aim of our study was to assess the commissural alignment of the balloon expandable SAPIEN 3 valve (Edwards Lifesciences) and to evaluate its impact on transvalvular gradient and mortality at 5 years of follow-up. Methods: Consecutive patients treated with SAPIEN 3 prosthesis guided with intraprocedural transesophageal echocardiogram (TEE) with a minimal follow-up of 5 years were included. Commissural alignment between the prosthesis and the native valve was measured by TEE by two independent cardiologists using a standardized 3-cusp view pre and post-valve deployment. CMA was defined as a neocommissure deviation > 30 degrees compared with native commissures. Echocardiographic gradients and clinical events were recorded during follow-up and compared between groups. Results: One hundred and five patients (54% male, mean age 80.4 years) were included; 63 (40%) were classified as "aligned" (CMA < 30 degrees) and 42 (60%) as "misaligned" (CMA > 30 degrees). Patients with CMA > 30 degrees presented smaller aortic annulus (23.8 vs. 20.7, p < 0.01) and received smaller valves. There was a slight increase of mean transvalvular gradient during follow-up (9.2-10.3 mmHg, p < 0.05), without significant differences between groups. Mortality rate was 16.2% at 1 year and 49.5% at 5 years; and not related to commissural alignment. Conclusions: Significant CMA is present in 40% of patients treated with SAPIEN 3 valves, however, we didn't find a significant association between CMA and gradient increase or mortality during long-term follow-up.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Quantification of Commissural Alignment of the BalloonExpandable SAPIEN 3 THV on Fluoroscopy
    Akodad, Mariama
    Tzimas, Georgios
    Meier, David
    Haugan, Delaney
    Gibson, Hannah
    Ringhofer, Justin
    Everett, Russell
    Sathananthan, Janarthanan
    Wood, David
    Webb, John
    Blanke, Philipp
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2022, 80 (12) : B198 - B199
  • [2] A Novel Method of Assessing Commissural Alignment for the Sapien 3 Transcatheter Aortic Valve
    Spilias, Nikolaos
    Sabbak, Nabil
    Reed, Grant
    Puri, Rishi
    Yun, James
    Unai, Shinya
    Krishnaswamy, Amar
    Harb, Serge
    Kapadia, Samir
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 76 (17) : B44 - B45
  • [3] A Novel Method of Assessing Commissural Alignment for the SAPIEN 3 Transcatheter Aortic Valve
    Spilias, Nikolaos
    Sabbak, Nabil
    Harb, Serge C.
    Yun, James J.
    Vargo, Patrick R.
    Unai, Shinya
    Puri, Rishi
    Reed, Grant W.
    Krishnaswamy, Amar
    Kapadia, Samir R.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2021, 14 (11) : 1269 - 1272
  • [4] PHONOCARDIOGRAPHIC FOLLOW-UP OF PROSTHETIC VALVES
    GRIMBERG, D
    DURON, F
    LUXEREAU, P
    POUGET, P
    ACAR, J
    COEUR ET MEDECINE INTERNE, 1975, 14 (02): : 255 - 263
  • [5] FOLLOW-UP OF MITRAL PROSTHETIC VALVES BY ECHOGRAPHY
    CHAPELLE, M
    COEUR ET MEDECINE INTERNE, 1974, 13 (04): : 659 - 662
  • [6] SODIUM GRADIENT AND MORTALITY IN HEMODIALYSIS PATIENS: 5 YEAR FOLLOW-UP ANALYSIS
    Selim, Gjulsen
    Stojceva-Taneva, Olivera
    Tozija, Liljana
    Georgievska-Ismail, Ljubica
    Gelev, Saso
    Dzekova-Vidimliski, Pavlina
    Trajceska, Lada
    Petronievic, Zvezdana
    Sikole, Aleksandar
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2013, 28 : 41 - 41
  • [7] POTASSIUM GRADIENT AND MORTALITY IN HEMODIALYSIS PATIENTS:5 YEAR FOLLOW-UP ANALYSIS
    Selim, Gjulshen
    Tozija, Liljana L.
    Zvezdana, Petronijevic
    Pavlina, Dzekova-Vidimlsiki
    Trajceska, Lada
    Nikola, Gjorgievski
    Svetlana, Pavleska
    Adrijana, Spasovska
    Angela, Kabova
    Bojana, Vrevezovska
    Spasovski, Goce
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2019, 34 : 260 - 260
  • [8] The impact of diabetes and stroke at baseline and during follow-up on stroke mortality
    Hu, G
    Jousilahti, P
    Tuomilehto, J
    DIABETOLOGIA, 2005, 48 : A84 - A84
  • [9] The Impact of Follow-Up on Mortality in Chronic Limb-Threatening Ischemia
    Bloch, Randall A.
    Ellias, Samia D.
    Caron, Elisa
    Shean, Katie E.
    Prushik, Scott G.
    Stone, David H.
    Conrad, Mark F.
    ANNALS OF VASCULAR SURGERY, 2025, 112 : 74 - 81
  • [10] Endobronchial Valves for Advanced Emphysema An Endobronchial Follow-up
    Salcedo, Pablo S.
    Seijo, Luis M.
    Zulueta, Javier J.
    JOURNAL OF BRONCHOLOGY & INTERVENTIONAL PULMONOLOGY, 2014, 21 (01) : 47 - 50