Enhanced Analytical Performance in CYFRA 21-1 Detection Using Lateral Flow Assay with Magnetic Bioconjugates: Integration and Comparison of Magnetic and Optical Registration

被引:0
|
作者
Skirda, Artemiy M. [1 ,2 ]
Orlov, Alexey V. [1 ]
Malkerov, Juri A. [1 ,3 ]
Znoyko, Sergey L. [1 ]
Rakitina, Alexandra S. [1 ,2 ]
Nikitin, Petr I. [1 ,3 ]
机构
[1] Russian Acad Sci, Prokhorov Gen Phys Inst, 38 Vavilov St, Moscow 119991, Russia
[2] Moscow Ctr Adv Studies, Kulakova Str 20, Moscow 123592, Russia
[3] Natl Res Nucl Univ MEPhI, Moscow Engn Phys Inst, 31 Kashirskoe Shosse, Moscow 115409, Russia
来源
BIOSENSORS-BASEL | 2024年 / 14卷 / 12期
关键词
lateral flow; immunochromatography; biosensing; immunoassay; nanoparticles; magnetic particles; point-of-care testing; tumor marker; CYFRA; 21-1; cytokeratin; 19; fragment; label-free; LUNG-CANCER; IN-VIVO; BIOMARKERS; EXPRESSION; BIOSENSORS; ACCURACY; SALIVARY; MARKER; TISSUE; SERUM;
D O I
10.3390/bios14120607
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel approach to developing lateral flow assays (LFAs) for the detection of CYFRA 21-1 (cytokeratin 19 fragment, a molecular biomarker for epithelial-origin cancers) is proposed. Magnetic bioconjugates (MBCs) were employed in combination with advanced optical and magnetic tools to optimize assay conditions. The approach integrates such techniques as label-free spectral-phase interferometry, colorimetric detection, and ultrasensitive magnetometry using the magnetic particle quantification (MPQ) technique. For the first time in LFA applications, the MPQ-based and colorimetry-based detection methods were compared side by side, and superior analytical performance was demonstrated. The limit of detection (LOD) of 0.9 pg/mL was achieved using MPQ, and 2.9 pg/mL with optical detection. This study has demonstrated that MPQ provides elimination of signal saturation, higher sensitivity (slope of the calibration curve), and a 19-fold wider dynamic range of detected signals. Both optical and magnetic detection results are comparable to the best laboratory-based tests with the added benefits of a 20-min assay duration and the LFA format convenience. The assay effectiveness was validated in human serum and artificial saliva, and high recovery rates were observed. The proposed approach offers rapid and reliable detection of molecular biomarkers and holds significant potential for point-of-care diagnostics, particularly in resource-limited settings.
引用
收藏
页数:13
相关论文
共 11 条
  • [1] Rapid detection of Cyfra 21-1 by optical-biosensing based on chemiluminescence immunoassay using bio-functionlized magnetic nanocomposites
    LUO JinPing
    QU ShuXue
    LIU JunTao
    WANG Bin
    CAI XinXia
    Science Bulletin, 2013, (21) : 2567 - 2569
  • [2] Rapid detection of Cyfra 21-1 by optical-biosensing based on chemiluminescence immunoassay using bio-functionlized magnetic nanocomposites
    Luo JinPing
    Qu ShuXue
    Liu JunTao
    Wang Bin
    Cai XinXia
    CHINESE SCIENCE BULLETIN, 2013, 58 (21): : 2567 - 2569
  • [3] Ultrasensitive detection of microbial cells using magnetic focus enhanced lateral flow sensors
    Ren, Wen
    Cho, Hoon
    Zhou, Zhongwu
    Irudayaraj, Joseph
    CHEMICAL COMMUNICATIONS, 2016, 52 (27) : 4930 - 4933
  • [4] Enhanced Lung Cancer Detection Using a Combined Ratio of Antigen-Autoantibody Immune Complexes against CYFRA 21-1 and p53
    Kim, Heyjin
    Lee, Jin Kyung
    Kim, Hye-Ryoun
    Hong, Young Jun
    CANCERS, 2024, 16 (15)
  • [5] An Enhanced Lateral Flow Assay Based on Aptamer-Magnetic Separation and Multifold AuNPs for Ultrasensitive Detection of Salmonella Typhimurium in Milk
    Gao, Pingping
    Wang, Lihan
    He, Yang
    Wang, Yitian
    Yang, Xinyan
    Fu, Shiqian
    Qin, Xue
    Chen, Qing
    Man, Chaoxin
    Jiang, Yujun
    FOODS, 2021, 10 (07)
  • [6] A novel assay for rapid HIV-1 protease detection using optical sensors and magnetic carriers
    Esseghaier, Chiheb
    Ng, Andy
    Zourob, Mohammed
    PHOTONICS NORTH 2012, 2012, 8412
  • [7] Universal and ultrasensitive detection of foodborne bacteria on a lateral flow assay strip by using wheat germ agglutinin-modified magnetic SERS nanotags
    Tu, Zhijie
    Cheng, Siyun
    Dong, Hao
    Wang, Wenqi
    Yang, Xingsheng
    Gu, Bing
    Wang, Shengqi
    Wang, Chongwen
    RSC ADVANCES, 2022, 12 (42) : 27344 - 27354
  • [8] Ultrasensitive SERS biosensor for synchronous detection of Escherichia coli O157:H7 and Pseudomonas aeruginosa via Cecropin 1-functionalized magnetic tags-based lateral flow assay
    Chen, Jin
    Liu, Xiaoxian
    Liu, Zhenzhen
    Ma, Jiayue
    Han, Jinyu
    Sun, Yinuo
    Liang, Jing
    Han, Han
    Zhao, Junnan
    Wang, Bingwei
    Xiao, Rui
    Wang, Yajie
    SENSORS AND ACTUATORS B-CHEMICAL, 2024, 409
  • [9] Non-Contrast-Enhanced Magnetic Resonance Angiography Using T2-Weighted 3-Dimensional Fat-Suppressed Turbo Spin Echo (SPACE): Diagnostic Performance and Comparison With Contrast-Enhanced Magnetic Resonance Angiography Using Volume Interpolated Breath-Hold Examination in the Detection of Portosystemic and Portohepatic Collaterals
    Song, Qiong
    Zeng, Mengsu
    Chen, Caizhong
    Ma, Jing
    Yun, Hong
    Rao, Shengxiang
    Yao, Xiuzhong
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2012, 36 (06) : 675 - 680
  • [10] Detection and characterization of focal liver lesions using superparamagnetic iron oxide-enhanced magnetic resonance imaging: comparison between ferumoxides-enhanced T1-weighted imaging and delayed-phase gadolinium-enhanced T1-weighted imaging
    Takahama, K
    Amano, Y
    Hayashi, H
    Ishihara, M
    Kumazaki, T
    ABDOMINAL IMAGING, 2003, 28 (04) : 525 - 530