The efficacy and safety of intrinsic antitachycardia pacing

被引:0
|
作者
Onuki, Koumei [1 ]
Nagashima, Michio [1 ]
Fukunaga, Masato [1 ]
Misonou, Keigo [1 ]
Kuroda, Maiko [1 ]
Kono, Hiroyuki [1 ]
Katsuki, Tomonori [1 ]
Kuji, Rei [1 ]
Korai, Kengo [1 ]
Hiroshima, Kenichi [1 ]
Ando, Kenji [1 ]
机构
[1] Kokura Mem Hosp, Dept Cardiol, Kitakyushu, Japan
关键词
acceleration; implantable cardioverter defibrillator; intrinsic antitachycardia pacing; postpacing interval; ventricular tachycardia;
D O I
10.1002/joa3.13221
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The clinical outcomes of a novel antitachycardia pacing (ATP) algorithm-intrinsic ATP (iATP)-compared to conventional ATP (cATP) have yet to be fully elucidated. Methods This retrospective study analyzed 128 patients and 1962 ventricular tachycardia (VT) episodes treated with the iATP or the cATP at Kokura Memorial Hospital. Patients were categorized into two groups: the iATP group (23 patients, 182 episodes) and the cATP group (105 patients, 1780 episodes). We evaluated ATP success rates and baseline patient characteristics on a per-patient basis. Additionally, we extracted VT that were not terminated by a single ATP and compared ATP success rates using propensity score matching. Results Per patient; The iATP group exhibited significantly lower creatinine levels (1.18 +/- 0.40 mg/dL vs. 1.82 +/- 1.61 mg/dL, p = .021) and a shorter follow-up period (609 +/- 323 days vs. 1017 +/- 252 days, p < .001) compared to the cATP group. ATP success was observed in 19 patients in the iATP group and 62 patients in the cATP group (82.6% vs. 59%, p = .054). Per episode; there was no significant difference in ATP success rate (91.8% vs. 92.7%, p = .645) or in acceleration rate (1.1% vs. 2.4%, p = .274). However, when limited to episodes in which VT was not terminated by a single ATP and propensity score matching was performed, the iATP showed a higher VT termination rate (84.1% vs. 53.6%, p < .001) and a lower acceleration rate (0% vs. 10.1%, p = .013) than the cATP. Conclusions The efficacy and safety of the iATP for VT that was not terminated by the first sequence of ATP was demonstrated.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Safety and efficacy of atrial antitachycardia pacing in congenital heart disease
    Kramer, Collin C.
    Maldonado, Jennifer R.
    Olson, Mark D.
    Gingerich, Jean C.
    Ochoa, Luis A.
    Law, Ian H.
    HEART RHYTHM, 2018, 15 (04) : 543 - 547
  • [2] Efficacy of intrinsic antitachycardia pacing for ventricular tachycardia refractory to conventional burst pacing: A case series
    Kamakura, Tsukasa
    Ueda, Nobuhiko
    Wada, Mitsuru
    Ishibashi, Kohei
    Kusano, Kengo
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2023, 34 (01) : 225 - 228
  • [3] EFFICACY OF BURST VS RAMP ANTITACHYCARDIA PACING AFTER FAILED BURST ANTITACHYCARDIA PACING
    Hindi, Mathew
    Schwab, Katerina
    Essebag, Vidal
    Birnie, David H.
    Tang, Anthony S. L.
    Thibault, Bernard
    Sterns, Laurence D.
    Parkash, Ratika
    Healey, Jeff S.
    Sapp, John Lewis, Jr.
    Nery, Pablo
    Sivakumaran, Soori
    Bennett, Matthew T.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 81 (08) : 26 - 26
  • [4] Antitachycardia pacing for slow VTs: efficacy and safety after a first unsuccessful attempt
    Jimenez-Candil, J.
    Duran, O.
    Hernandez, J.
    Morinigo, J. L.
    Bravo, L.
    Sanchez, P. L.
    EUROPEAN HEART JOURNAL, 2018, 39 : 216 - 217
  • [5] REPLY: Proarrhythmic Effect of Intrinsic Antitachycardia Pacing Is Only the Pacing Algorithm to be Blamed?
    Raina, Anvi
    van Zyl, Martin
    Henrich, Mark
    Deshmukh, Abhishek J.
    Kowlgi, Gurukripa N.
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2023, 9 (10) : 2171 - 2171
  • [6] Antitachycardia pacing
    Gillette, PC
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (08): : 2121 - 2124
  • [7] EFFICACY OF A VARIABLE ANTITACHYCARDIA PACING MODE IN SUPRAVENTRICULAR TACHYCARDIA
    PFITZNER, P
    GERCKENS, U
    FUNKE, HD
    MOHR, F
    MANZ, M
    LUDERITZ, B
    ZEITSCHRIFT FUR KARDIOLOGIE, 1988, 77 (06): : 366 - 372
  • [8] Atrial antitachycardia pacing efficacy based on time and rhythm
    Daoud, EG
    Hoyt, R
    Nademanee, K
    Fuenzalida, C
    Reeve, H
    Simones, M
    Stone, C
    Schwartz, M
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) : 126A - 126A
  • [9] Safety and efficacy of programming a high number of antitachycardia pacing attempts for fast ventricular tachycardia: a prospective study
    Martins, Raphael P.
    Blangy, Hugues
    Muresan, Lucian
    Freysz, Luc
    Groben, Laurent
    Zinzius, Pierre-Yves
    Schwartz, Jerome
    Sellal, Jean-Marc
    Aliot, Etienne
    Sadoul, Nicolas
    EUROPACE, 2012, 14 (10): : 1457 - 1464
  • [10] The influence of antitachycardia pacing site on efficacy of ventricular tachycardia termination
    Wathen, MS
    Yee, R
    Birgersdotter-Green, U
    Belk, P
    Christensen, J
    Jackson, TE
    CIRCULATION, 2004, 110 (17) : 443 - 443