Thermal performance analysis of molten salt in transversely grooved tube for nuclear reactor

被引:1
|
作者
Raheem, Aneeq [1 ]
Siddique, Waseem [1 ]
Awais, Muhammad [2 ]
Qureshi, Kamran [1 ]
Nawaz, Rab [2 ]
Ul Hassan, Syed Wajeeh [1 ]
Zaki, Muhammad [3 ]
机构
[1] Pakistan Inst Engn & Appl Sci, Dept Mech Engn, Islamabad 45650, Pakistan
[2] Pakistan Inst Engn & Appl Sci, Dept Nucl Engn, Islamabad, Pakistan
[3] Pakistan Inst Engn & Appl Sci, Dept Chem Engn, Islamabad, Pakistan
关键词
Computational fluid dynamics (CFD); heat transfer enhancement; grooved channel; molten salt; CONVECTIVE HEAT-TRANSFER; FLUORIDE-SALT; TRANSFER ENHANCEMENT; TURBULENT-FLOW; PRESSURE-DROP; STORAGE; CONDUCTIVITY; TRANSITION; CHANNEL;
D O I
10.1080/00223131.2024.2425390
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Molten salts are prospective candidates for core cooling of advanced high-temperature reactors. In the present work, a numerical investigation is performed to analyze the thermal-hydraulic performance of molten nitrate salt in a transversely grooved tube by varying geometrical parameters. The effect of geometric parameters on Nusselt number, friction factor, and thermal enhancement factor has been expressed in the form of dimensionless factors: groove height to tube diameter ratio (e/d) ranged from 0.038 to 0.092 and groove pitch to diameter ratio (P/d) ranged from 0.5 to 1.5, for Reynolds number ranged from 11,000 to 30,000. Results show that the thermal performance of molten salt in a transversely grooved tube is dominated by geometrical parameters. In general, the Nusselt number and friction factor have been found to be increased with an increase in groove height and with a decrease in groove pitch. The highest value of the Nusselt number is achieved for the highest groove height (e/d = 0.092) and lowest groove pitch (P/d = 0.5) with corresponding maximum pressure drop. As a result, a tradeoff between heat transfer and pressure drop is achieved at e/d = 0.038 and P/d = 1.5 for Re = 11645 for the best overall thermal performance of molten salt in a transversely grooved tube.
引用
收藏
页码:288 / 299
页数:12
相关论文
共 50 条
  • [1] Thermal performance analysis of molten salt in transversely grooved tube for nuclear reactor
    Raheem, Aneeq
    Siddique, Waseem
    Awais, Muhammad
    Qureshi, Kamran
    Nawaz, Rab
    Ul Hassan, Syed Wajeeh
    Zaki, Muhammad
    Journal of Nuclear Science and Technology, 2024,
  • [2] Thermal performance analysis of molten salt in transversely grooved tube for nuclear reactor (Nov, 10.1080/00223131.2024.2425390, 2024)
    Awais, Muhammad
    Siddique, Waseem
    Raheem, Aneeq
    Qureshi, Kamran
    Nawaz, Rab
    Ul Hassan, Syed Wajeeh
    Zaki, Muhammad
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2025,
  • [4] Convective heat transfer of high temperature molten salt in transversely grooved tube
    Lu Jianfeng
    Shen Xiangyang
    Ding Jing
    Peng Qiang
    Wen Yuliang
    APPLIED THERMAL ENGINEERING, 2013, 61 (02) : 157 - 162
  • [5] THE COMPATIBILITY OF NUCLEAR GRAPHITE WITH MOLTEN SALT IN THE MOLTEN SALT REACTOR
    He, Zhoutong
    Tang, Hui
    Zhang, Can
    Gao, Yantao
    Xia, Huihao
    Zhou, Xingtai
    PROCEEDINGS OF THE 26TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, 2018, VOL 2, 2018,
  • [6] Steady thermal hydraulic analysis for a molten salt reactor
    ZHANG Dalin1
    NuclearScienceandTechniques, 2008, (03) : 187 - 192
  • [7] Steady thermal hydraulic analysis for a molten salt reactor
    Zhang Dalin
    Qiu Suizheng
    Liu Changliang
    Su Guanghui
    NUCLEAR SCIENCE AND TECHNIQUES, 2008, 19 (03) : 187 - 192
  • [9] The ultimate safe nuclear reactor: the molten salt reactor
    Rice, A
    SOUTH AFRICAN JOURNAL OF SCIENCE, 2002, 98 (3-4) : 117 - 118
  • [10] Coupled Analysis of Thermal Hydraulics and Neutronics for a Molten Salt Reactor
    Ge, Jian
    Zhang, Dalin
    Tian, Wenxi
    Qiu, Suizheng
    Su, G. H.
    PROCEEDINGS OF THE 25TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, 2017, VOL 8, 2017,