Surface properties and metal ions leaching behaviors of nickel-titanium orthodontic archwires modified by oxidation

被引:0
|
作者
Chang, S. H. [1 ]
Lin, J. X. [1 ]
Chiang, C. H. [1 ]
机构
[1] Natl Ilan Univ, Dept Chem & Mat Engn, Ilan 260, Taiwan
关键词
Nickel-titanium; Surface modification; Heat treatment; Selective leaching; Electrochemical property; NITI SHAPE-MEMORY; CORROSION-RESISTANCE; ALLOYS; BIOCOMPATIBILITY; CYTOTOXICITY;
D O I
10.15251/DJNB.2024.194
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
This study examined the metal ions released from nickel-titanium (TiNi) orthodontic archwires, which had been surface-modified by oxidation at various temperatures. The Ni ion was more easily leached from the TiNi orthodontic archwires than Ti ion, because the Ti atoms were readily to form passive TiO2 films on the surface. TiNi orthodontic archwires should be heat-treated at an appropriate temperature, such as 300 and 400 degrees C, to possess a smooth and intact TiO2 film on the surface, better corrosion-resistance properties, and fewer selectively leached Ni ions to ensure the long-term safety of the implantation. TiNi orthodontic archwires heat-treated at a higher temperature, such as 500 degrees C, may lead to poor corrosion-resistance properties and risk the increase of selectively leached Ni ions.
引用
收藏
页码:1825 / 1834
页数:10
相关论文
共 50 条
  • [1] Comparison of Elastic Properties of Nickel-Titanium Orthodontic Archwires
    Sarul, Michal
    Kawala, Beata
    Antoszewska, Joanna
    ADVANCES IN CLINICAL AND EXPERIMENTAL MEDICINE, 2013, 22 (02): : 253 - 260
  • [2] Surface characteristics of retrieved coated and nickel-titanium orthodontic archwires
    Zegan, Georgeta
    Sodor, Alina
    Munteanu, C.
    ROMANIAN JOURNAL OF MORPHOLOGY AND EMBRYOLOGY, 2012, 53 (04): : 935 - 939
  • [3] COMPARISONS OF THE THERMODYNAMIC PROPERTIES OF 3 NICKEL-TITANIUM ORTHODONTIC ARCHWIRES
    BISHARA, SE
    ORTHO, D
    WINTERBOTTOM, JM
    SULIEMAN, AHA
    RIM, K
    JAKOBSEN, JR
    ANGLE ORTHODONTIST, 1995, 65 (02) : 117 - 122
  • [4] In vitro biocompatibility of nickel-titanium esthetic orthodontic archwires
    Rongo, Roberto
    Valletta, Rosa
    Buccia, Rosaria
    Rivieccio, Virginia
    Galeotti, Angela
    Michelotti, Ambrosina
    D'Anto, Vincenzo
    ANGLE ORTHODONTIST, 2016, 86 (05) : 789 - 795
  • [5] A comparison of the bending behaviour of nickel-titanium orthodontic archwires
    Lester, KJ
    Mori, T
    Sims, MR
    JOURNAL OF DENTAL RESEARCH, 1997, 76 (05) : 937 - 937
  • [6] Evaluation of nanomechanical properties, surface roughness, and color stability of esthetic nickel-titanium orthodontic archwires
    Alsanea, Jamal A.
    Al Shehri, Hassan
    JOURNAL OF INTERNATIONAL SOCIETY OF PREVENTIVE AND COMMUNITY DENTISTRY, 2019, 9 (01): : 33 - 39
  • [7] FUNCTIONAL PROPERTIES OF SUPERELASTIC ORTHODONTIC NICKEL-TITANIUM ARCHWIRES WITH PROTECTIVE TITANIUM NITRIDE COATINGS
    Rubanik, Vasili V.
    Rubanik, Vasili V., Jr.
    Bahrets, Dzmitry A.
    Dorodeiko, Viachaslau G.
    DOKLADY NATSIONALNOI AKADEMII NAUK BELARUSI, 2019, 63 (05): : 608 - 619
  • [8] Effect of gastric acids on surface topography and bending properties of esthetic coated nickel-titanium orthodontic archwires
    Shaymaa Elsaka
    Ali Hassan
    Amr Elnaghy
    Clinical Oral Investigations, 2021, 25 : 1319 - 1326
  • [9] Effect of loading force on the dissolution behavior and surface properties of nickel-titanium orthodontic archwires in artificial saliva
    Liu, Jia-Kuang
    Lee, Tzer-Min
    Liu, I-Hua
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2011, 140 (02) : 166 - 176
  • [10] Effect of gastric acids on surface topography and bending properties of esthetic coated nickel-titanium orthodontic archwires
    Elsaka, Shaymaa
    Hassan, Ali
    Elnaghy, Amr
    CLINICAL ORAL INVESTIGATIONS, 2021, 25 (03) : 1319 - 1326