Three-dimensional aortic arch geometry and blood flow in neonates after surgical repair for aortic coarctation

被引:0
|
作者
Fricke, Katrin [1 ,2 ]
Christierson, Lea [1 ,2 ,3 ]
Heiberg, Einar [3 ,4 ]
Sjoberg, Pia [4 ,5 ]
Hedstrom, Erik [4 ,5 ,6 ,7 ]
Steiner, Kristoffer [8 ]
Weismann, Constance G. [1 ,2 ,9 ]
Toger, Johannes [3 ,4 ]
Liuba, Petru [1 ,2 ]
机构
[1] Skane Univ Hosp, Pediat Heart Ctr, Pediat Cardiol, Lund, Sweden
[2] Lund Univ, Dept Clin Sci Lund, Pediat, Lund, Sweden
[3] Lund Univ, Dept Biomed Engn, Lund, Sweden
[4] Lund Univ, Dept Clin Sci Lund, Clin Physiol, Lund, Sweden
[5] Skane Univ Hosp, Dept Clin Physiol, Lund, Sweden
[6] Lund Univ, Dept Clin Sci Lund, Diagnost Radiol, Lund, Sweden
[7] Skane Univ Hosp, Dept Radiol, Lund, Sweden
[8] Karolinska Inst, Dept Womens & Childrens Hlth, Stockholm, Sweden
[9] Ludwig Maximilians Univ Munchen, Dept Pediat Cardiol & Pediat Intens Care, Munich, Germany
来源
基金
瑞典研究理事会;
关键词
neonatal coarctation; magnetic resonance; three-dimensional aortic arch geometry; four-dimensional flow; recurrent coarctation; TO-END ANASTOMOSIS; RECOARCTATION; OBSTRUCTION; RESECTION; OUTCOMES; INFANTS; SURGERY; PATCH; SHAPE;
D O I
10.3389/fcvm.2024.1518070
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Recurrent coarctation of the aorta (re-CoA) is a well-known although not fully understood complication after surgical repair, typically occurring in 10%-20% of cases within months after discharge.Objectives To (1) characterize geometry of the aortic arch and blood flow from pre-discharge magnetic resonance imaging (MRI) in neonates after CoA repair; and (2) compare these measures between patients that developed re-CoA within 12 months after repair and patients who did not.Methods Neonates needing CoA repair, without associated major congenital heart defects, were included. Transthoracic echocardiography (echo) and 4D phase-contrast MRI were performed prior to discharge after CoA repair to assess 3D arch geometry, flow velocity and flow pattern in the distal aortic arch corresponding to the area at risk for re-CoA. Arch geometry was assessed by measuring angles of the aortic arch and its branches using 3D patient-specific geometries segmented from MRI. Continuous data are presented as median and interquartile range.Results The median age at CoA surgery was 9 days. Four out of the included 28 patients (14%) developed re-CoA within the first 12 months after surgery. Re-CoA was associated with repair technique (lateral thoracotomy 100% vs. 33%, p = 0.02), higher postoperative isthmic flow velocity by echocardiography (1.9 [0. 9] m/s vs. 1.25 [0.5] m/s, p = 0.04) and postoperative crenel aortic arch (100% vs. 21%, p = 0.007) with a larger distance between the first and last branching points (12.6 [3.1] mm vs. 7.3 [7.0] mm; p = 0.01). A smaller angle between the ascending aorta and the brachiocephalic artery (89 [58]degrees vs. 122 [37]degrees, p = 0.05) and between the proximal aortic arch and the left carotid artery (75 degrees vs. 97 [37]degrees, p = 0.04), with a more pronounced caliber change between the ascending aorta and the proximal (1.85 vs. 0.86 [0.76]; p = 0.03) and distal aortic arch (2.19 [2.42] vs. 1.01 [0.94]; p = 0.03) were observed in re-CoA patients. Patients who developed re-CoA had more left-handed helical flow in systole (p = 0.045), more right-handed helical flow in diastole (p = 0.02), and less vortical flow (p = 0.05).Conclusion Subtle changes in aortic arch geometry and flow pattern early after neonatal CoA repair may contribute to the risk of re-CoA.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Timing of surgical repair of the stented aortic arch and coarctation in neonates
    Gonzalez-Calle, Antonio
    Guillen-Rodriguez, Inmaculada
    Coserria-Sanchez, Felix
    CARDIOLOGY IN THE YOUNG, 2023, 33 (01) : 147 - 148
  • [2] Aortic valve and aortic arch pathology after coarctation repair
    Roos-Hesselink, JW
    Schölzel, BE
    Heijdra, RJ
    Spitaels, SEC
    Meijboom, FJ
    Boersma, E
    Bogers, AJJC
    Simoons, ML
    HEART, 2003, 89 (09) : 1074 - 1077
  • [3] SURGICAL MANAGEMENT OF SEVERE AORTIC COARCTATION AND INTERRUPTED AORTIC-ARCH IN NEONATES
    FISHMAN, NH
    BRONSTEIN, MH
    BERMAN, W
    ROE, BB
    EDMUNDS, LH
    ROBINSON, SJ
    RUDOLPH, AM
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1976, 71 (01): : 35 - 48
  • [4] Unsteady and three-dimensional simulation of blood flow in the human aortic arch
    Shahcheraghi, N
    Dwyer, HA
    Cheer, AY
    Barakat, AI
    Rutaganira, T
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2002, 124 (04): : 378 - 387
  • [5] Aortic Arch Advancement for Aortic Coarctation and Hypoplastic Aortic Arch in Neonates and Infants
    Mery, Carlos M.
    Guzman-Pruneda, Francisco A.
    Carberry, Kathleen E.
    Watrin, Carmen H.
    McChesney, Grant R.
    Chan, Joyce G.
    Adachi, Iki
    Heinle, Jeffrey S.
    McKenzie, E. Dean
    Fraser, Charles D., Jr.
    ANNALS OF THORACIC SURGERY, 2014, 98 (02): : 625 - 633
  • [6] Vascular remodeling after "successful" repair of coarctation - Impact of aortic arch geometry
    Ou, Phalla
    Celermajer, David S.
    Mousseaux, Elie
    Giron, Alain
    Aggoun, Yacine
    Szezepanski, Isabelle
    Sidi, Daniel
    Bonnet, Damien
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (08) : 883 - 890
  • [7] Three-dimensional lattice Boltzmann method for simulating blood flow in aortic arch
    康秀英
    吉驭嫔
    刘大禾
    金永娟
    Chinese Physics B, 2008, (03) : 1041 - 1049
  • [8] Three-dimensional lattice Boltzmann method for simulating blood flow in aortic arch
    Kang, Xiu-Ying
    Ji, Yu-Pin
    Liu, Da-He
    Jin, Yong-Juan
    2008, Institute of Physics Publishing, Temple Back, Bristol, BS1 6BE, United Kingdom (17):
  • [9] Three-dimensional lattice Boltzmann method for simulating blood flow in aortic arch
    Kang Xiu-Ying
    Ji Yu-Pin
    Liu Da-He
    Jin Yong-Juan
    CHINESE PHYSICS B, 2008, 17 (03) : 1041 - 1049
  • [10] Outcome after extended arch repair for aortic coarctation
    Thomson, JDR
    Mulpur, A
    Guerrero, R
    Nagy, Z
    Gibbs, JL
    Watterson, KG
    HEART, 2006, 92 (01) : 90 - 94