Construction of Nonenzymatic Flexible Electrochemical Sensor for Glucose Using Bimetallic Copper Ferrite/Sulfur-Doped Graphene Oxide Water-Based Conductive Ink by Noninvasive Method

被引:0
|
作者
Uruc, Selen [1 ,2 ]
Gorduk, Ozge [1 ]
Sahin, Yucel [1 ]
机构
[1] Yildiz Tech Univ, Fac Arts & Sci, Dept Chem, TR-34220 Istanbul, Turkiye
[2] Marmara Univ, Fac Pharm, Dept Basic Pharmaceut Sci, TR-34015 Istanbul, Turkiye
来源
ACS APPLIED BIO MATERIALS | 2025年 / 8卷 / 02期
关键词
Glucose; nonenzymatic; flexible sensor; screen printed electrode; wearable sensor; SCREEN-PRINTED ELECTRODES; SOLVOTHERMAL SYNTHESIS; PERFORMANCE; CUO; COMPOSITES; PHASE; IONS;
D O I
10.1021/acsabm.4c01674
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Diabetes is a chronic disease that results in elevated blood glucose levels due to insufficient insulin production by the pancreas or impaired insulin utilization by the body. The development of effective tools for the in vitro detection of blood glucose is of paramount importance. Flexible electrodes serve as indispensable components in point-of-care systems, thus increasing accessibility and personalization in health monitoring. We present the preparation of handmade screen-printed electrode with water-based conductive ink for in vitro nonenzymatic glucose (Glu) determination at physiological pH values. The investigation aimed to identify the optimal conditions for formulating and composing the conductive ink used to create a copper ferrite/sulfur-doped graphene oxide/graphite/screen-printed electrode (CuFe2O4/S-GO/G/SPE). The resulting CuFe2O4/S-GO/G/SPE shows excellent glucose sensing ability with a limit of detection (LOD) of 2.93 mu M. The superior determination at physiological pH is attributed to the complex structure formed by CuFe2O4 nanoparticles with glucose molecules in the basic pH conductive ink structure. Additionally, the excellent delocalization and conductivity of the S-GO particles in this complex structure contribute to improved performance. The study on artificial sweat samples resulted in achieving recovery values of 96.60% to 104.97%. In conclusion, the nonenzymatic and noninvasive Glu sensor printed with conductive ink containing CuFe2O4/S-GO/G on a flexible paper substrate surface demonstrated remarkable capabilities for determining Glu levels in artificial sweat samples. SPEs prepared with conductive ink produced by using these materials are promising candidates for use as electrodes in flexible and wearable sensor technology.
引用
收藏
页码:1451 / 1465
页数:15
相关论文
共 8 条
  • [1] Utilization of a Selective Paper-Based Flexible Electrochemical Sensor for Epinephrine Determination in Artificial Sweat Using Nickel Oxide and Sulfur-Doped Graphene Conductive Ink
    Oner, Esra
    Uruc, Selen
    Dokur, Ebrar
    Gorduk, Ozge
    Sahin, Yucel
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2025, 172 (02)
  • [2] Flexible Screen-Printed Electrode for Cortisol Detection Based on Sulfur-Doped Graphene/Gold Nanoparticles Conductive Ink
    Umuksuz, Hazal
    Uruc, Selen
    Dokur, Ebrar
    Gorduk, Ozge
    Sahin, Yucel
    ECS JOURNAL OF SOLID STATE SCIENCE AND TECHNOLOGY, 2025, 14 (02)
  • [3] Water-based chitosan/reduced graphene oxide ink for extrusion printing of a disposable amperometric glucose sensor
    Sanati, Alireza
    Bidram, Elham
    Poursamar, Ali
    Rabbani, Mohsen
    Rafienia, Mohammad
    FLATCHEM, 2022, 36
  • [4] Heteroatom-doped graphene oxide-based conductive ink: synthesis, characterization and investigation of the conductivity properties for flexible sensor technology
    Uruc, Selen
    Dokur, Ebrar
    Kurteli, Rabianur
    Gorduk, Ozge
    Sahin, Yucel
    NEW JOURNAL OF CHEMISTRY, 2023, 47 (26) : 12360 - 12374
  • [5] Electrochemical synthesis of mixed-valence manganese/copper hybrid composite using graphene oxide and multi-walled carbon nanotubes for nonenzymatic glucose sensor
    Lin, Kuo-Chiang
    Huang, Lin-Hsiang
    Chen, Shen-Ming
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2014, 735 : 36 - 42
  • [6] Rational design and preparation of copper vanadate anchored on sulfur doped reduced graphene oxide nanocomposite for electrochemical sensing of antiandrogen drug nilutamide using flexible electrodes
    Sharma, Tata Sanjay Kanna
    Hwa, Kuo-Yuan
    JOURNAL OF HAZARDOUS MATERIALS, 2021, 410
  • [7] New strategy for non-enzymatic determination of lactate via regeneration of cofactor NADH using flexible electrochemical sensors prepared with nitrogen-doped graphene oxide conductive ink
    Dokur, Ebrar
    Gorduk, Ozge
    Sahin, Yucel
    FLATCHEM, 2025, 51
  • [8] Simple preparation and highly selective detection of silver ions using an electrochemical sensor based on sulfur-doped graphene and a 3,3′,5,5′-tetramethylbenzidine composite modified electrode
    Fu, Yang
    Yang, Yajie
    Tuersun, Tayierjiang
    Yu, Yuan
    Zhi, Jinfang
    ANALYST, 2018, 143 (09) : 2076 - 2082