Physical and chemical changes of clear aligners after thermoforming and intraoral exposure

被引:0
|
作者
Dalaie, Kazem [1 ]
Rafsanjan, Katayoun Talebi [1 ]
Nojehdehian, Hanieh [2 ]
Namazi, Zahra [2 ]
机构
[1] Shahid Beheshti Univ Med Sci, Dept Orthodont, Tehran, Iran
[2] Shahid Beheshti Univ Med Sci, Dept Dent Biomat, Tehran, Iran
关键词
Clear aligner appliances; Hardness; X-Ray diffraction; Spectroscopy; Fourier transform infrared; Glass transition; Thermoforming; THERMOPLASTIC MATERIALS; MECHANICAL-PROPERTIES; FORCE;
D O I
10.25259/APOS_169_2023
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: This study assessed the physical and chemical changes of clear aligners after thermoforming and intraoral exposure. Material and Methods: This ex vivo study evaluated raw sheets, thermoformed sheets, and aligners used for 2 weeks from two commercial brands of Erkodur and Shinseki (n = 8 in each group). The surface hardness (by the Vickers hardness test), thickness (by a digital caliper), and glass transition temperature (Tg) (by differential scanning calorimetry) of the specimens were measured, and they underwent X-ray diffraction (XRD) to assess their degree of crystallinity and attenuated total reflectance-Fourier-transform infrared spectroscopy (ATR-FTIR) for analysis of their molecular composition. Data were analyzed by one-sample, paired and independent t-tests, and Mann-Whitney U and Wilcoxon signed-rank tests (alpha = 0.05). Results: The XRD and ATR-FTIR spectra of Erkodur and Shinseki aligners matched those of polyethylene terephthalate glycol polymer and did not change after thermoforming or intraoral exposure. Unlike intraoral exposure (P > 0.05), thermoforming significantly decreased the hardness of both brands of aligners (P < 0.05). Intraoral exposure significantly decreased the thickness of Erkodur aligners at some points and significantly increased the thickness of Shinseki aligners (P < 0.05). Thermoforming significantly decreased the Tg of both brands of aligners (P < 0.05). Intraoral exposure significantly decreased the Tg of Erkodur and increased the Tg of Shinseki aligners (P = 0.000). Conclusion: Erkodur and Shinseki aligners showed high chemical and structural stability after thermoforming and 2 weeks of intraoral exposure. However, thermoforming affected the thermal and physical properties of both brands of aligners. Erkodur aligners had higher dimensional stability than Shinseki aligners.
引用
收藏
页码:235 / 247
页数:13
相关论文
共 50 条
  • [1] Thickness of orthodontic clear aligners after thermoforming and after 10 days of intraoral exposure: a prospective clinical study
    Rosaria Bucci
    Roberto Rongo
    Carmine Levatè
    Ambrosina Michelotti
    Sandro Barone
    Armando Viviano Razionale
    Vincenzo D’Antò
    Progress in Orthodontics, 20
  • [2] Thickness of orthodontic clear aligners after thermoforming and after 10 days of intraoral exposure: a prospective clinical study
    Bucci, Rosaria
    Rongo, Roberto
    Levate, Carmine
    Michelotti, Ambrosina
    Barone, Sandro
    Razionale, Armando Viviano
    D'Anto, Vincenzo
    PROGRESS IN ORTHODONTICS, 2019, 20 (01)
  • [3] Dynamic mechanical and thermal properties of clear aligners after thermoforming and aging
    Kazem Dalaie
    Seyyed Mostafa Fatemi
    Samin Ghaffari
    Progress in Orthodontics, 22
  • [4] Dynamic mechanical and thermal properties of clear aligners after thermoforming and aging
    Dalaie, Kazem
    Fatemi, Seyyed Mostafa
    Ghaffari, Samin
    PROGRESS IN ORTHODONTICS, 2021, 22 (01)
  • [5] Effect of oral exposure on chemical, physical, mechanical, and morphologic properties of clear orthodontic aligners
    Lira, Larine Ferreira
    Vargas, Eduardo Otero Amaral
    da Silva, Eduardo Moreira
    Maia, Juliana Nunes da Silva Meirelles Doria
    Elzubair, Amal
    de Morais, Liliane Siqueira
    Camargo Jr, Sergio Alvaro de Souza
    Serra, Glaucio
    de Souza, Margareth Maria Gomes
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2023, 164 (02) : E51 - E63
  • [6] Changes in surface morphology, chemical and mechanical properties of clear aligners during intraoral usage: A systematic review and meta-analysis
    Bakdach, Wesam Mhd Mounir
    Haiba, Majed
    Hadad, Rania
    INTERNATIONAL ORTHODONTICS, 2022, 20 (01)
  • [7] Evaluation of mechanical changes to clear aligners caused by exposure to different liquids
    Sari, Tarik
    Camci, Hasan
    Aslantas, Kubilay
    AUSTRALASIAN ORTHODONTIC JOURNAL, 2024, 40 (02): : 75 - 86
  • [8] The Mechanical Properties of Orthodontic Aligners of Clear Aligner After Intraoral Use in Different Time Periods
    Siotou, Kalliopi
    Chountalas, Theofanis
    Katsavrias, Athanasios
    Siotos, Charalampos
    Mpalias, Konstantinos
    Semitekolos, Dionysios
    Charitidis, Constantinos
    Tsolakis, Apostolos I.
    ORTHODONTICS & CRANIOFACIAL RESEARCH, 2025, 28 (02) : 253 - 260
  • [9] Changes in the Microbiome of the Inner Surface of Clear Aligners After Different Usage Periods
    Dong Yan
    Yi Liu
    Xiaoxia Che
    Sicong Mi
    Yao Jiao
    Lijia Guo
    Song Li
    Current Microbiology, 2021, 78 : 566 - 575
  • [10] Changes in the Microbiome of the Inner Surface of Clear Aligners After Different Usage Periods
    Yan, Dong
    Liu, Yi
    Che, Xiaoxia
    Mi, Sicong
    Jiao, Yao
    Guo, Lijia
    Li, Song
    CURRENT MICROBIOLOGY, 2021, 78 (02) : 566 - 575