Preoperative Predictors of Recurrent Tricuspid Regurgitation After Annuloplasty: Insights into the Role of 3D Echocardiography

被引:0
|
作者
Krivickiene, Ausra [1 ,2 ]
Verikas, Dovydas [1 ,2 ]
Padervinskiene, Lina [3 ]
Mizariene, Vaida [1 ]
Siudikas, Adakrius [4 ]
Jakuska, Povilas [4 ]
Vaskelyte, Jolanta Justina [1 ,2 ]
Ereminiene, Egle [1 ,2 ]
机构
[1] Lithuanian Univ Hlth Sci, Med Acad, Dept Cardiol, LT-44307 Kaunas, Lithuania
[2] Lithuanian Univ Hlth Sci, Inst Cardiol, LT-50162 Kaunas, Lithuania
[3] Lithuanian Univ Hlth Sci, Med Acad, Dept Radiol, LT-44307 Kaunas, Lithuania
[4] Lithuanian Univ Hlth Sci, Med Acad, Dept Cardiac Thorac & Vasc Surg, LT-50161 Kaunas, Lithuania
关键词
tricuspid valve; tricuspid regurgitation; 3D-echocardiography; recurrent tricuspid regurgitation; tricuspid annuloplasty; 3-DIMENSIONAL ECHOCARDIOGRAPHY; ANNULAR CIRCUMFERENCE; EUROPEAN ASSOCIATION; RISK-FACTORS; VALVE; RECOMMENDATIONS; DETERMINANTS; PROGRESSION; SURGERY; ADULTS;
D O I
10.3390/diagnostics14222515
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: While tricuspid annuloplasty (TAP) is an effective treatment option for tricuspid regurgitation (TR), understanding the echocardiographic factors contributing to recurrent TR can help in developing more effective preventive measures to reduce the rate of recurrent TR after TAP. Methods: This study was designed as a prospective observational cohort study to investigate factors contributing to recurrent TR following surgical tricuspid valve (TV) repair in patients with moderate or severe functional TR caused by left heart valvular disease, with severe mitral regurgitation as the dominant pathology. The study included 66 patients who underwent preoperative two-dimensional (2D) and three-dimensional (3D) echocardiographic assessments. Patients were divided into two groups based on TAP outcomes: the effective TAP group and the recurrent TR group. Results: The analysis revealed that 3D-derived both septal-lateral diastolic and systolic tricuspid annulus (TA) diameter (odds ratio (OR) 1.77; 95% confidence interval (CI) 1.17-2.68 and OR 1.62; 95% CI 1.14-2.29, respectively), and major axis diastolic TA diameter (OR 1.59; 95% CI 1.15-2.2) had the highest OR among all echocardiographic parameters. The further univariate analysis of predefined echocardiographic values unveiled that the combined effect of heightened 3D-measured TA major axis diastolic diameter and increased right ventricle (RV) basal diameter exhibited the highest OR at 12.8 (95% CI 2.3-72.8) for a recurrent TR. Using ROC analysis, diastolic major axis (area under the curve (AUC) 0.848; cut-off 48.5 mm), septal-lateral systolic (AUC 0.840; cut-off 43.5 mm) and diastolic (AUC 0.840; cut-off 46.5 mm) TA diameter demonstrated the highest predictive value for recurrent TR from all TV parameters. Conclusions: Recurrent moderate or severe TR after TAP is associated with preoperative TA size, right atrium and RV geometry, but not with changes of RV function. The predictive capacity of 2D-assessed echocardiographic parameters was found to be lower when compared to their corresponding 3D parameters.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Preoperative predictors of recurrent tricuspid regurgitation after annuloplasty: insights into the role of 3D echocardiography
    Krivickiene, A.
    Verikas, D.
    Kreckauskiene, R.
    Gujyte, G.
    Ereminiene, E.
    EUROPEAN HEART JOURNAL, 2023, 44
  • [2] Predictive factors for recurrent tricuspid regurgitation after tricuspid annuloplasty: 3D echocardiography study
    Verikas, D.
    Krivickiene, A.
    Jakuska, P.
    Siudikas, A.
    Vaskelyte, J. J.
    Ereminiene, E.
    EUROPEAN HEART JOURNAL, 2024, 45
  • [3] Prognostic preoperative factors for recurrence of tricuspid regurgitation following annuloplasty: examining the influence of 3d echocardiography
    Verikas, D.
    Krivickiene, A.
    Jakuska, P.
    Siudikas, A.
    Vaskelyte, J. J.
    Ereminiene, E.
    EUROPEAN HEART JOURNAL, 2024, 45
  • [4] 3D Echocardiography for Traumatic Tricuspid Regurgitation
    Looi, Jen Li
    Lee, Alex Pui-Wai
    Wong, Randolph H. L.
    Yu, Cheuk-Man
    JACC-CARDIOVASCULAR IMAGING, 2012, 5 (12) : 1285 - 1287
  • [5] Determinants of recurrent or residual functional tricuspid regurgitation after tricuspid annuloplasty
    Fukuda, Shota
    Gillinov, A. Marc
    McCarthy, Patrick M.
    Stewart, William J.
    Song, Jong-Min
    Kihara, Takashi
    Daimon, Masao
    Shin, Mi-Seong
    Thomas, James D.
    Shiota, Takahiro
    CIRCULATION, 2006, 114 : I582 - I587
  • [6] Geometric Changes and Predictors of Residual Tricuspid Regurgitation After Tricuspid Annuloplasty: A Real-Time 3-Dimensional Echocardiography Study
    Min, Sun-Yang
    Song, Jong-Min
    Kim, Jeong-Hoon
    Jang, Min-Kyong
    Kim, Yun-Jeong
    Kim, Dae-Hee
    Lee, Jae Won
    Kang, Duk-Hyun
    Song, Jae-Kwan
    CIRCULATION, 2009, 120 (18) : S804 - S804
  • [7] Usefulness of 3D echocardiographic parameters of tricuspid valve morphology to predict residual tricuspid regurgitation after tricuspid annuloplasty
    Utsunomiya, Hiroto
    Itabashi, Yuji
    Mihara, Hirotsugu
    Kobayashi, Sayuki
    De Robertis, Michele A.
    Trento, Alfredo
    Shiota, Takahiro
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2017, 18 (07) : 809 - 817
  • [8] Incidence and predictors of tricuspid regurgitation determined by 2D and 3D echocardiography after permanent pacemaker insertion
    Rangel, J. P.
    Flores, V. B.
    EUROPEAN JOURNAL OF HEART FAILURE, 2018, 20 : 524 - 524
  • [9] Tricuspid regurgitation repair with a MitraClip device: the pivotal role of 3D transoesophageal echocardiography
    Avenatti, Eleonora
    Barker, Colin M.
    Little, Stephen H.
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2017, 18 (03) : 380 - 380
  • [10] Geometric changes after tricuspid annuloplasty and predictors of residual tricuspid regurgitation: a real-time three-dimensional echocardiography study
    Min, Sun-Yang
    Song, Jong-Min
    Kim, Jeong-Hoon
    Jang, Min-Kyong
    Kim, Yun-Jeong
    Song, Haeguen
    Kim, Dae-Hee
    Lee, Jae Won
    Kang, Duk-Hyun
    Song, Jae-Kwan
    EUROPEAN HEART JOURNAL, 2010, 31 (23) : 2871 - 2880