Internal rotation limitation is prevalent following modern reverse shoulder arthroplasty and negatively affects patients' subjective rating of the procedure
被引:0
|
作者:
Kim, Mike
论文数: 0引用数: 0
h-index: 0
机构:
Univ Missouri, Dept Orthopaed Surg, 1100 Virginia Ave, Columbia, MO 65212 USAUniv Missouri, Dept Orthopaed Surg, 1100 Virginia Ave, Columbia, MO 65212 USA
Kim, Mike
[1
]
Nguyen, Michael
论文数: 0引用数: 0
h-index: 0
机构:
Univ Missouri, Dept Orthopaed Surg, 1100 Virginia Ave, Columbia, MO 65212 USAUniv Missouri, Dept Orthopaed Surg, 1100 Virginia Ave, Columbia, MO 65212 USA
Nguyen, Michael
[1
]
Groneck, Andrew
论文数: 0引用数: 0
h-index: 0
机构:
Univ Missouri, Dept Orthopaed Surg, 1100 Virginia Ave, Columbia, MO 65212 USAUniv Missouri, Dept Orthopaed Surg, 1100 Virginia Ave, Columbia, MO 65212 USA
Groneck, Andrew
[1
]
机构:
[1] Univ Missouri, Dept Orthopaed Surg, 1100 Virginia Ave, Columbia, MO 65212 USA
Background: Although forward elevation, abduction, and external rotation are often successfully restored, internal rotation (IR) is frequently not satisfactorily recovered following reverse shoulder arthroplasty (RSA), affecting patients' ability to perform certain daily activities. This study examined the prevalence of limited IR in patients receiving modern RSA and its impact on clinical outcomes and patient satisfaction with their RSA. Methods: A cross-sectional study was conducted on patients who had undergone primary RSA using a modern RSA prosthesis with a minimum 1-year follow-up. Patients returned for a research visit where they were examined for range of motion and surveyed for patient-reported outcome measures (PROMs) and subjective rating of the success level of their RSA. Postoperative range of motion data were compared with the preoperative data. The relationship of postoperative IR with PROMs and patients' subjective rating of RSA was analyzed. Logistic regression was performed to identify factors affecting patients' subjective rating of RSA. Results: A total of 78 patients met the criteria and completed the study. A significant portion (59%) reported subjective IR limitations, and 41% had objective IR limitations. Comparison of preoperative and postoperative IR showed that 24% had worsened IR, whereas 33% improved. Limited IR was associated with lower patients' subjective rating of RSA and negatively affected PROMs, especially when the dominant side was operated on. Regression analysis showed that limited IR was the only independent determining factor that was significantly associated with a lower subjective rating of RSA. Discussion: Despite advancements in RSA design, limited IR remains a prevalent issue, significantly affecting patients' satisfaction and clinical outcomes. This study underscores the need for setting appropriate expectations regarding IR through patient education and focused efforts to improve IR limitations in RSA patients, particularly on the dominant side. (c) 2024 Journal of Shoulder and Elbow Surgery Board of Trustees. All rights reserved.
机构:
CHP St Gregoire, St Gregoire, France
Luxor Univ, Fac Med, New Tiba City, EgyptCHP St Gregoire, St Gregoire, France
Adam, Mahmoud Faisal
Ladermann, Alexandre
论文数: 0引用数: 0
h-index: 0
机构:
Hop La Tour, Div Orthopaed & Trauma Surg, Meyrin, Switzerland
Geneva Univ Hosp, Div Orthopaed & Trauma Surg, Dept Surg, Geneva, Switzerland
Univ Geneva, Fac Med, Geneva, SwitzerlandCHP St Gregoire, St Gregoire, France
Ladermann, Alexandre
Denard, Patrick J.
论文数: 0引用数: 0
h-index: 0
机构:
Oregon Shoulder Inst, Medford, OR USACHP St Gregoire, St Gregoire, France
Denard, Patrick J.
Lacerda, Felipe
论文数: 0引用数: 0
h-index: 0
机构:
CHP St Gregoire, St Gregoire, France
Orthoped Ctr Barra, Rio De Janeiro, Brazil
Clin Meta, Rio De Janeiro, BrazilCHP St Gregoire, St Gregoire, France
Lacerda, Felipe
Collin, Philippe
论文数: 0引用数: 0
h-index: 0
机构:
CHP St Gregoire, St Gregoire, France
Clin Victor Hugo, Paris, France
Amer Hosp Paris, Neuilly Sur Seine, FranceCHP St Gregoire, St Gregoire, France
机构:
Congress Med Fdn, Orthoped Biomech Lab, 800 S Raymond Ave, Pasadena, CA 91105 USACongress Med Fdn, Orthoped Biomech Lab, 800 S Raymond Ave, Pasadena, CA 91105 USA
Baek, Gyu Rim
Kim, Jung Gon
论文数: 0引用数: 0
h-index: 0
机构:
Yeosu Baek Hosp, Dept Orthopaed Surg, Yeosu, Jeonranamdo, South KoreaCongress Med Fdn, Orthoped Biomech Lab, 800 S Raymond Ave, Pasadena, CA 91105 USA
Kim, Jung Gon
Baek, Chang Hee
论文数: 0引用数: 0
h-index: 0
机构:
Yeosu Baek Hosp, Dept Orthopaed Surg, Yeosu, Jeonranamdo, South KoreaCongress Med Fdn, Orthoped Biomech Lab, 800 S Raymond Ave, Pasadena, CA 91105 USA
Baek, Chang Hee
Baek, Gyuna
论文数: 0引用数: 0
h-index: 0
机构:
Congress Med Fdn, Orthoped Biomech Lab, 800 S Raymond Ave, Pasadena, CA 91105 USACongress Med Fdn, Orthoped Biomech Lab, 800 S Raymond Ave, Pasadena, CA 91105 USA
Baek, Gyuna
Chung, Min-Shik
论文数: 0引用数: 0
h-index: 0
机构:
Congress Med Fdn, Orthoped Biomech Lab, 800 S Raymond Ave, Pasadena, CA 91105 USACongress Med Fdn, Orthoped Biomech Lab, 800 S Raymond Ave, Pasadena, CA 91105 USA
Chung, Min-Shik
Kao, Owen
论文数: 0引用数: 0
h-index: 0
机构:
Congress Med Fdn, Orthoped Biomech Lab, 800 S Raymond Ave, Pasadena, CA 91105 USACongress Med Fdn, Orthoped Biomech Lab, 800 S Raymond Ave, Pasadena, CA 91105 USA
Kao, Owen
McGarry, Michelle H.
论文数: 0引用数: 0
h-index: 0
机构:
Congress Med Fdn, Orthoped Biomech Lab, 800 S Raymond Ave, Pasadena, CA 91105 USACongress Med Fdn, Orthoped Biomech Lab, 800 S Raymond Ave, Pasadena, CA 91105 USA
McGarry, Michelle H.
Lee, Thay Q.
论文数: 0引用数: 0
h-index: 0
机构:
Congress Med Fdn, Orthoped Biomech Lab, 800 S Raymond Ave, Pasadena, CA 91105 USACongress Med Fdn, Orthoped Biomech Lab, 800 S Raymond Ave, Pasadena, CA 91105 USA