Biventricular vs. right ventricular pacing devices in patients anticipated to require frequent ventricular pacing (BioPace)

被引:0
|
作者
Funck, Reinhard C. [1 ,12 ]
Mueller, Hans-Helge [2 ]
Lunati, Maurizio [3 ]
De Roy, Luc [4 ]
Klein, Norbert [5 ]
Meisel, Eckhard [6 ]
Milasinovic, Goran [7 ]
Carlson, Mark D. [8 ]
Wittenberg, Michael [9 ]
Hindricks, Gerhard [10 ]
Blanc, Jean-Jacques [11 ]
机构
[1] Univ Marburg, Klin Innere Med Kardiol, Baldingerstr, D-35033 Marburg, Germany
[2] Philipps Univ Marburg, Inst Med Bioinformat & Biostat, Hans Meerwein Str 6, D-35043 Marburg, Germany
[3] Osped Niguarda Ca Granda, Cardiol Elettrofisiol 3, Piazza Osped Maggiore 3, I-20162 Milan, Italy
[4] CHU Namur, Cardiol Dept, Ave G Therasse 1-8, B-5530 Yvoir, Belgium
[5] Klinikum St Georg gGmbH, Dept Cardiol, Delitzscher Str 141, D-04129 Leipzig, Germany
[6] August Bebel Str 33, D-01219 Dresden, Germany
[7] Klinicki Ctr Srbije, Pacemaker Clin, Beograd 11000, Serbia
[8] Abbott Cardiac Arrhythmias & Heart Failure, Sylmar, CA 91342 USA
[9] Philipps Univ Marburg, Coordinating Ctr Clin Trials, Karl von Frisch Str 4, D-35043 Marburg, Germany
[10] Campus Charite Mitte, Dept Cardiol Angiol & Intens Care Med, Charitepl 1, D-10117 Berlin, Germany
[11] Brest Univ Hosp, Dept Cardiol, Blvd Tanguy Prigent, F-29609 Brest, France
[12] Schmiedeweg 6, D-35274 Kirchhain, Germany
来源
EUROPACE | 2025年 / 27卷 / 03期
关键词
Cardiac pacing; Right ventricular pacing; Pacing-induced cardiomyopathy; Biventricular pacing; Heart failure; Mortality; CARDIAC-RESYNCHRONIZATION THERAPY; CONGESTIVE-HEART-FAILURE; ATRIOVENTRICULAR-BLOCK; INDUCED CARDIOMYOPATHY; STIMULATION; PACEMAKER; DESIGN; DESYNCHRONIZATION; DEFIBRILLATOR; DYSFUNCTION;
D O I
10.1093/europace/euaf029
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Right ventricular (RV) pacing may promote left ventricular (LV) dysfunction. Particularly in patients with preserved LV ejection fraction (LVEF), narrow QRS, and anticipated high ventricular pacing burden (HVPB), evidence is missing that biventricular (BiV) pacing can improve clinical outcome. We therefore evaluated whether implantation of a BiV pacing device (BiVPD) compared with a RV pacing device (RVPD) may improve clinical outcome in predominantly this kind of patients.Methods and results In the Biventricular Pacing for atrioventricular Block to Prevent Cardiac Desynchronization (BioPace) trial [multicentre, single-blinded (patients), randomized, parallel group], patients were equally allocated to either receive a BiVPD or a RVPD. Co-primary endpoints were (i) the composite of time to death or first heart failure hospitalization and (ii) survival time. We analysed 1810 randomized patients (median age: 73.5 years; female sex: 31.7%; mean LVEF 55.4%; mean QRS 118.4 ms), 902 to BiV and 908 to RV pacing. During mean follow-up of 68.8 months, the difference in the primary composite endpoint between both groups [346 vs. 363 events, hazard ratio (HR) 0.878; 95% confidence interval (CI) 0.756-1.020; P = 0.0882) or in mortality (305 vs. 307 deaths, HR 0.926; 95% CI 0.789-1.088; P = 0.3492) was smaller than 20%.Conclusion In patients, predominantly with preserved LVEF, narrow QRS, and HVPB, superiority of implanting BiVPDs compared with RVPDs could not be proven. Right ventricular pacing may be less harmful for this kind of patients than often suggested and primary BiV pacing does not clearly improve their clinical outcome.Clinical trial registration Registered in ClinicalTrials.gov, number NCT00187278 (https://clinicaltrials.gov/ct2/show/study/NCT00187278).
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Conduction system pacing vs. biventricular pacing in patients with ventricular dysfunction and AV block
    Pujol-Lopez, Margarida
    Arjona, Rafael Jimenez
    Guasch, Eduard
    Borras, Roger
    Doltra, Adelina
    Vazquez-Calvo, Sara
    Roca-Luque, Ivo
    Garre, Paz
    Ferro, Elisenda
    Niebla, Mireia
    Carro, Esther
    Puente, Jose L.
    Uribe, Laura
    Invers, Eric
    Castel, Maria Angeles
    Arbelo, Elena
    Sitges, Marta
    Mont, Lluis
    Tolosana, Jose M.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2022, 45 (09): : 1115 - 1123
  • [2] BIVENTRICULAR PACING IN PATIENTS WITH LEFT VENTRICULAR ASSIST DEVICES - IS LEFT VENTRICULAR PACING PROARRHYTHMIC??
    Choi, Andrew D.
    Fischer, Avi
    Anyanwu, Anelechi
    Pinney, Sean
    Adler, Eric
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10)
  • [3] Biventricular Pacing Versus Right Ventricular Pacing in Patients Supported With LVAD
    Chung, Ben B.
    Grinstein, Jonathan S.
    Imamura, Teruhiko
    Kruse, Eric
    Nguyen, Ann B.
    Narang, Nikhil
    Holzhauser, Luise H.
    Burkhoff, Daniel
    Lang, Roberto M.
    Sayer, Gabriel T.
    Uriel, Nir Y.
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2021, 7 (08) : 1003 - 1009
  • [4] Right Ventricular Pacing vs. Biventricular Pacing in Cardiac Amyloidosis: A Prospective, Randomized, Crossover Pilot Study
    Chyou, Janice Y.
    Helmke, Stephen
    Teruya, Sergio
    Alvarez, Julissa
    Maurer, Mathew
    Dizon, Jose
    CIRCULATION, 2018, 138
  • [5] Is right ventricular outflow tract pacing an alternative to left ventricular/biventricular pacing?
    Riedlbauchová, L
    Kautzner, J
    Hatala, R
    Buckingham, TA
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2004, 27 (06): : 871 - 877
  • [6] Upgrading from right ventricular apical pacing to biventricular pacing
    Schoenfeld, MH
    CARDIAC ARRHYTHMIAS 2003, 2004, : 815 - 822
  • [7] Biventricular pacing in patients with right ventricular pacing-induced heart failure
    Witte, Klaus K.
    Parker, John D.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2007, 18 (02) : E12 - E12
  • [8] Will biventricular pacing replace right ventricular pacing for antibradycardia therapy?
    Barold, S. Serge
    Herweg, Bengt
    EXPERT REVIEW OF MEDICAL DEVICES, 2013, 10 (05) : 591 - 596
  • [9] Optimal Pacing for Right Ventricular and Biventricular Devices Minimizing, Maximizing, and Right Ventricular/Left Ventricular Site Considerations
    Gillis, Anne M.
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2014, 7 (05): : 968 - U386
  • [10] May right ventricular outflow tract pacing be an alternative for biventricular pacing?
    Kutarski, A
    Sodolski, T
    Rucinski, P
    Trojnar, M
    EUROPEAN HEART JOURNAL, 2004, 25 : 177 - 177