Outcomes of hand-made versus commercial stent grafts in frozen elephant trunk

被引:0
|
作者
Kanemitsu, Shinji [1 ]
Ishikawa, Renta [1 ]
Sakamoto, Shunsuke [1 ]
Mizumoto, Toru [1 ]
机构
[1] Anjo Kosei Hosp, Dept Cardiovasc Surg, Anjo, Aichi 4468602, Japan
关键词
Total arch replacement; frozen elephant trunk technique; aortic arch aneurysm; EXPERIENCE; ANEURYSM; RISK;
D O I
10.1177/00368504241278415
中图分类号
G40 [教育学];
学科分类号
040101 ; 120403 ;
摘要
Objectives The frozen elephant trunk (FET) technique is effective for treating extended aortic arch aneurysms. This study compares hand-made and factory-made devices in this context. Methods A retrospective case-control study was conducted on 68 patients who underwent FET for distal aortic arch aneurysm at our institution. We used two different types of devices: hand-made stent graft in group Z (17 cases, 25.0%) and a commercialized stent graft in group J (51 cases, 75.0%). The study compared demographic characteristics and the outcomes between the two groups. Results In-hospital mortality was equivalent in both groups (5.9%). Spinal cord injury rates were 5.9% in group Z and 3.9% in group J. Group Z had a higher rate of aortic events (55.9% vs 96.9%, p < 0.001) and more frequent stent migration. The number of cases with aneurysm diameter shrinkage was lower in group Z. The landing zone angle at insertion influenced aneurysm changes, being 17.6 degrees in shrink cases and 26.7 degrees in unchanged or enlarged cases (p = 0.045). Conclusions FROZENIX device notably reduced incidences of postoperative complications compared to hand-made prostheses. Factors such as insertion angle and stent size, rather than changes in the landing zone angle, appeared to influence aneurysm shrinkage. The use of FROZENIX in TARFET procedures has shown benefits in reducing complications and improving long-term prognosis, taking into account the landing zone angle.
引用
收藏
页数:14
相关论文
共 50 条
  • [2] Comparison of the outcomes of the sling technique using a commercial and hand-made polypropylene sling
    Oliveira Brito, Luciane Maria
    Silva Sousa, Antonio de Padua
    de Figueire-do Neto, Jose Albuquerque
    Duarte, Thaiana Bezerra
    Pinheiro, George do Lago
    da Costa Chein, Maria Bethania
    INTERNATIONAL BRAZ J UROL, 2011, 37 (04): : 519 - 527
  • [3] Aortic arch repair with frozen elephant trunk versus conventional elephant trunk
    Cekmecelioglu, Davut
    Coselli, Joseph S.
    ANNALS OF CARDIOTHORACIC SURGERY, 2020, 9 (03) : 223 - 225
  • [4] Comparison of the outcomes of the TOT technique using a hand-made TOT material and a commercial one
    Ozdemir, Ahmet Tunc
    Altinova, Serkan
    Cimen, Haci Ibrahim
    Serefoglu, Ege Can
    Koyuncu, Hasbey Hakan
    Gurdal, Mesut
    TURKISH JOURNAL OF MEDICAL SCIENCES, 2012, 42 : 1230 - 1234
  • [5] The need for custom made frozen elephant trunk: when and where
    Chivasso, Pierpaolo
    Masiello, Paolo
    Miele, Mario
    Bruno, Vito Domenico
    Genovino, Alba Chiara
    Iesu, Ivana
    Triggiani, Donato
    Colombino, Mario
    Cafarelli, Francesco
    Leone, Rocco
    Mastrogiovanni, Generoso
    Iesu, Severino
    CARDIOVASCULAR DIAGNOSIS AND THERAPY, 2022, : 516 - 520
  • [6] PIV Analysis of Haemodynamics Distal to the Frozen Elephant Trunk Stent Surrogate
    Petra N. Williamson
    Paul D. Docherty
    Sina G. Yazdi
    Adib Khanafer
    Natalia Kabaliuk
    Mark Jermy
    Cardiovascular Engineering and Technology, 2021, 12 : 373 - 386
  • [7] Distortion of a Hybrid Stent Graft Following a Frozen Elephant Trunk Procedure
    Deschka, Heinz
    Nolte, Thomas
    Machner, Matthias
    Wimmer-Greinecker, Gerhard
    JOURNAL OF CARDIAC SURGERY, 2014, 29 (05) : 650 - 652
  • [8] Spontaneous Dislocation of a Frozen Elephant Trunk Stent Graft Into the False Lumen
    Kreibich, Maximilian
    Rylski, Bartosz
    Beyersdorf, Friedhelm
    Czerny, Martin
    Siepe, Matthias
    ANNALS OF THORACIC SURGERY, 2022, 113 (01): : E81 - E81
  • [9] Longer stent graft in frozen elephant trunk procedure: A fear or truth?
    Idhrees, Mohammed
    Bashir, Mohamad
    JOURNAL OF CARDIAC SURGERY, 2021, 36 (09) : 3269 - 3270
  • [10] PIV Analysis of Haemodynamics Distal to the Frozen Elephant Trunk Stent Surrogate
    Williamson, Petra N.
    Docherty, Paul D.
    Yazdi, Sina G.
    Khanafer, Adib
    Kabaliuk, Natalia
    Jermy, Mark
    CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2021, 12 (04) : 373 - 386