Effects of Loading Forces, Loading Positions, and Splinting of Two, Three, or Four Ti-Zr (Roxolid®) Mini-Implants Supporting the Mandibular Overdentures on Peri-Implant and Posterior Edentulous Area Strains

被引:2
|
作者
Petricevic, Nikola [1 ]
Celebic, Asja [1 ]
Puljic, Dario [1 ]
Milat, Ognjen [2 ]
Divjak, Alan [3 ]
Kovacic, Ines [1 ]
机构
[1] Univ Zagreb, Sch Dent Med, Dept Removable Prosthodont, Zagreb 10000, Croatia
[2] Inst Phys, Zagreb 10000, Croatia
[3] Univ Algebra, Dept Digital Arts, Zagreb 10000, Croatia
关键词
Ti-Zr mini-implants; strain gauges; mandibular overdenture; loading forces; number of implants; splinting; peri-implant strains; edentulous area strains; NARROW-DIAMETER IMPLANTS; BITE-FORCE; BONE-RESORPTION; SINGLE CROWNS; OUTCOMES; STANDARD; SURVIVAL;
D O I
10.3390/jfb15090260
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Clinical indications for the Ti-Zr alloy (Roxolid (R)) mini-implants (MDIs) in subjects with narrow ridges are still under review. The aim was to analyze peri-implant and posterior edentulous area strains dependent on the MDI number, splinting status, loading force, and loading position. Six models were digitally designed and printed. Two, three, or four Ti-Zr MDIs, splinted with a bar or unsplinted (single units), supported mandibular overdentures (ODs), loaded with 50-300 N forces unilaterally, bilaterally, and anteriorly. The artificial mucosa thickness was 2 mm. Strain gauges were bonded on the vestibular and oral peri-implant sides of each MDI, and on the posterior edentulous area under the ODs. Loadings were performed through the metal plate placed on ODs' artificial teeth (15 times repeated). Arithmetic means with standard deviations and the significance of the differences (MANOVA, Sheffe post hoc) were calculated. Different MDI numbers, loading positions, forces, and splinting elicited different peri-implant microstrains. In the two-MDI models, 300 N force during unilateral loading elicited the highest microstrains (almost 3000 epsilon mu on the loaded side), which can jeopardize bone reparation. On the opposite side, >2500 epsilon mu was registered, which represents high strains. During bilateral loadings, microstrains hardly exceeded 2000 epsilon mu, indicating that bilateral chewers or subjects having lower forces can benefit from the two Ti-Zr MDIs, irrespective of splinting. However, in subjects chewing unilaterally, and inducing higher forces (natural teeth antagonists), or bruxers, only two MDIs may not be sufficient to support the OD. By increasing implant numbers, peri-implant strains decrease in both splinted and single-unit MDI models, far beyond values that can interfere with bone reparation, indicating that splinting is not necessary. When the positions of the loading forces are closer to the implant, higher peri-implant strains are induced. Regarding the distal edentulous area, microstrains reached 2000 epsilon mu only during unilateral loadings in the two-MDI models, and all other strains were lower, below 1500 epsilon mu, confirming that implant-supported overdentures do not lead to edentulous ridge atrophy.
引用
收藏
页数:23
相关论文
共 2 条
  • [1] Influence of Implant Number on Peri-Implant and Posterior Edentulous Area Strains in Mandibular Overdentures Retained by the New Ti-Zr (Roxolid®) Mini-Implants as Single-Units: In Vitro Study
    Puljic, Dario
    Celebic, Asja
    Kovacic, Ines
    Petricevic, Nikola
    APPLIED SCIENCES-BASEL, 2024, 14 (05):
  • [2] Mandibular Overdenture Supported by Two or Four Unsplinted or Two Splinted Ti-Zr Mini-Implants: In Vitro Study of Peri-Implant and Edentulous Area Strains
    Puljic, Dario
    Petricevic, Nikola
    Celebic, Asja
    Kovacic, Ines
    Milos, Manuela
    Pavic, Dalibor
    Milat, Ognjen
    BIOMIMETICS, 2024, 9 (03)