Does Catheter Insertion Site Matter? Contamination of Peripheral Intravenous Catheters during Dental Scaling in Dogs

被引:0
|
作者
Calice, Ivana [1 ]
Ballas, Panagiotis [2 ]
Vogl, Claus [3 ]
Purwin, Sandra [1 ,2 ]
Ehling-Schulz, Monika [2 ]
Rocchi, Attilio [1 ]
机构
[1] Vet Med Univ Vienna, Dept Small Anim & Horses, Clin Small Anim, Clin Unit Anaesthesiol & Perioperat Intens Care Me, A-1210 Vienna, Austria
[2] Vet Med Univ Vienna, Inst Microbiol, Dept Pathobiol, A-1210 Vienna, Austria
[3] Vet Med Univ Vienna, Dept Biomed Sci, A-1210 Vienna, Austria
关键词
contamination; peripheral intravenous catheter; dental scaling; dog; cannula; BACTERIAL; INFECTIONS; GUIDELINES; AEROSOL; BLOOD;
D O I
10.3390/vetsci11090407
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
During dental scaling in dogs under general anaesthesia, contamination of the peripheral intravenous catheter (PIVC) is unavoidable due to splatter and the generated aerosol. Bacterial contamination was compared between two commonly used PIVC placement sites. Thirty-nine client-owned dogs with a minimum length from their nose to their tail base of 50 cm were randomly assigned to receive a PIVC in either their cephalic or saphenous vein. Irrespective of the PIVC placement site, brain heart infusion agar dishes were placed in the cephalic and saphenous vein areas. Their lids were closed 0, 5, and 10 min into the procedure. Contamination was measured by counting the colony-forming units after incubation on different substrates. The data were analysed with descriptive statistics, ANOVA, and ANCOVA (p < 0.05). The cephalic vein area showed a significantly higher bacterial load than the saphenous vein area (p approximate to 0.0) regardless of the length of the dog. Furthermore, the dorsal PIVC injection ports were sampled before and after scaling, and the colonies isolated were counted and subjected to MALDI-TOF-MS for identification. The bacteria mainly belonged to the genera Staphylococcus, Neisseria, and Bacillus. Our results suggest that for dental scaling in dogs, the PIVC should be placed in the pelvic limb whenever possible to reduce the potential risk of contamination.
引用
收藏
页数:13
相关论文
共 17 条
  • [1] Factors contributing to the contamination of peripheral intravenous catheters in dogs and cats
    Jones, I. D.
    Case, A. M.
    Stevens, K. B.
    Boag, A.
    Rycroft, A. N.
    VETERINARY RECORD, 2009, 164 (20) : 616 - 618
  • [2] Paramedic insertion of peripheral intravenous catheters, unused catheter rates, and influencing factors: A retrospective review
    Golling, Eleanor
    Barr, Nigel
    van de Mortel, Thea
    Zimmerman, Peta-Anne
    AMERICAN JOURNAL OF INFECTION CONTROL, 2023, 51 (12) : 1411 - 1416
  • [3] Pain upon inserting a peripheral intravenous catheter: Size does not matter
    van Loon, Fredericus H. J.
    Puijn, Lisette A. P. M.
    van Aarle, Wesly H.
    Dierick-van Daele, Angelique T. M.
    Bouwman, Arthur R. A.
    JOURNAL OF VASCULAR ACCESS, 2018, 19 (03): : 258 - 265
  • [4] Differences in catheter-related complications to insertion site selection for long peripheral intravenous catheters in antimicrobial therapy: a randomized controlled trial
    Zhao, Linfang
    Jin, Xianghong
    Li, Xiangyun
    Liu, Chang
    Wang, Jie
    Cao, Xiuzhu
    Zeng, Xufen
    Zhuang, Yiyu
    BMC NURSING, 2025, 24 (01):
  • [5] Exploring the causes of peripheral intravenous catheter failure based on shape of catheters removed from various insertion sites
    Murayama, Ryoko
    Takahashi, Toshiaki
    Tanabe, Hidenori
    Yabunaka, Koichi
    Oe, Makoto
    Komiyama, Chieko
    Sanada, Hiromi
    DRUG DISCOVERIES AND THERAPEUTICS, 2018, 12 (03): : 170 - 177
  • [6] No evidence that medicinal honey reduces bacterial skin colonisation at a peripheral catheter insertion site in dogs
    Royaux, E.
    Polis, I.
    Boyen, F.
    Van Ham, L.
    de Rooster, H.
    JOURNAL OF SMALL ANIMAL PRACTICE, 2016, 57 (07) : 374 - 378
  • [7] Ultrasound-Guided Peripheral Intravenous Catheter Insertion Training Reduces Use of Midline Catheters in Hospitalized Patients With Difficult Intravenous Access
    Amick, Ashley E.
    Feinsmith, Sarah E.
    Sell, Jordan
    Davis, Evan M.
    Wayne, Diane B.
    Feinglass, Joseph
    Barsuk, Jeffrey H.
    JOURNAL OF PATIENT SAFETY, 2022, 18 (03) : E697 - E703
  • [8] Does the Use of an Assistive Device by Nurses Impact Peripheral Intravenous Catheter Insertion Success in Children?
    Peterson, Kimberly A.
    Phillips, Amy L.
    Truemper, Edward
    Agrawal, Sangeeta
    JOURNAL OF PEDIATRIC NURSING-NURSING CARE OF CHILDREN & FAMILIES, 2012, 27 (02): : 134 - 143
  • [9] Length of hospitalization, APPLE score, and number of intravenous catheters placed at admission are associated with increased odds of peripheral intravenous catheter complications in dogs
    Granger Jr, Kyle L. Granger
    Guieu, Liz-Valerie
    Zersen, Kristin M.
    JAVMA-JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 2024, 262 (01):
  • [10] Insertion site and risk of peripheral intravenous catheter colonization and/or local infection: a post hoc analysis of the CLEAN 3 study including more than 800 catheters
    Drugeon, Bertrand
    Marjanovic, Nicolas
    Boisson, Matthieu
    Buetti, Niccolo
    Mimoz, Olivier
    Guenezan, Jeremy