Impact of Hypothermic Oxygenated Machine Perfusion on Immune Cell Clearance in Liver Transplantation: Enhancing Graft Function and Post-Transplant Outcomes

被引:0
|
作者
Koch, Dominik Thomas [1 ]
Schirren, Malte [1 ]
Jacobi, Severin [1 ]
Niess, Hanno [1 ]
Renz, Bernhard Willibald [1 ]
Werner, Jens [1 ]
Guba, Markus Otto [1 ]
Koliogiannis, Dionysios [1 ]
机构
[1] Ludwig Maximilians Univ Munchen, LMU Univ Hosp, Dept Gen Visceral & Transplantat Surg, Marchioninistr 15, D-81377 Munich, Germany
关键词
liver transplantation; hypothermic oxygenated machine perfusion; immune cell clearance; immune cell characterization; ISCHEMIA-REPERFUSION INJURY; MECHANISMS; BLOOD;
D O I
10.3390/jcm14010127
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Hypothermic oxygenated machine perfusion (HOPE) has emerged as a critical innovation in liver transplantation (LTx), offering significant protection against ischemia-reperfusion injury (IRI). This study focuses on quantifying and characterizing immune cells flushed out during HOPE to explore its effects on graft function and post-transplant outcomes. Materials and Methods: Fifty liver grafts underwent end-ischemic HOPE. Perfusate samples were collected at three time points: at the start of perfusion, after 10 min, and at the end of perfusion. The samples were analyzed to quantify and characterize immune cells, assessing the effectiveness of HOPE in reducing cellular debris and its impact on graft quality. Results: The primary perfusate contained significant concentrations of immune cells, mainly segmented neutrophils, lymphocytes, and monocytes. After 10 min of perfusion, outflow cell concentration decreased by over 95%, and by the end of perfusion, a more than 99% reduction was observed. Conclusions: HOPE effectively reduces immune cell concentrations in liver grafts, suggesting a mechanism for improved graft function and reduced post-transplant complications. These findings support the continued use and optimization of HOPE in LTx.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] IMPACT OF HYPOTHERMIC OXYGENATED MACHINE PERFUSION (HOPE) ON IMMUNE RESPONSE IN A RODENT MODEL OF LIVER TRANSPLANTATION
    Schlegel, A.
    Kron, P.
    Graf, R.
    Clavien, P. -A.
    Dutkowski, P.
    JOURNAL OF HEPATOLOGY, 2014, 60 (01) : S530 - S531
  • [2] Dual hypothermic oxygenated machine perfusion of the liver reduces post-transplant biliary complications: a retrospective cohort study
    Pereyra, David
    Dingfelder, Jule
    Riha, Moriz
    Kacar, Sertac
    Rauter, Laurin
    Becker, Nikolaus
    Saffarian Zadeh, Tina
    Tortopis, Chiara
    Starlinger, Patrick
    Ristl, Robin
    Silberhumer, Gerd
    Salat, Andreas
    Soliman, Thomas
    Berlakovich, Gabriela
    Gyoeri, Georg
    INTERNATIONAL JOURNAL OF SURGERY, 2024, 110 (12) : 7909 - 7918
  • [3] Novel real time prediction of liver graft function during hypothermic oxygenated machine perfusion prior to liver transplantation
    Schlegel, A.
    Mueller, X.
    Kron, P.
    Eshmuminov, D.
    Wuerdinger, M.
    Meierhofer, D.
    Clavien, P. -A
    Dutkowski, P.
    TRANSPLANTATION, 2019, 103 (08) : 50 - 51
  • [4] Novel real time prediction of liver graft function during hypothermic oxygenated machine perfusion prior to liver transplantation
    Dutkowski, Philipp
    Muller, Xavier
    Schlegel, Andrea
    Kron, Philipp
    Eshmuminov, Dilmurodjon
    Wuerdinger, Michael
    Meierhofer, David
    Clavien, Pierre-Alain
    JOURNAL OF HEPATOLOGY, 2019, 70 (01) : E104 - E105
  • [5] Does Machine Perfusion of the Liver Allograft Impact Post-Transplant Renal Function?
    Munoz, Nicolas
    Cywes, Claire
    Banker, Amay M.
    Abt, Peter L.
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2024, 239 (05) : S489 - S489
  • [6] CHARACTERIZATION AND POST-TRANSPLANT OUTCOMES OF MACHINE PERFUSION ORGANS FOR LIVER RE- TRANSPLANTATION
    Wang, Roy
    Abt, Peter
    Bittermann, Therese
    HEPATOLOGY, 2024, 80 : S972 - S973
  • [7] Hypothermic Oxygenated Machine Perfusion for Liver Transplantation: An Initial Experience
    Patrono, Damiano
    Lavezzo, Bruna
    Molinaro, Luca
    Rizza, Giorgia
    Catalano, Giorgia
    Gonella, Federica
    Salizzoni, Mauro
    Romagnoli, Renato
    EXPERIMENTAL AND CLINICAL TRANSPLANTATION, 2018, 16 (02) : 172 - 176
  • [8] Novel Real-time Prediction of Liver Graft Function During Hypothermic Oxygenated Machine Perfusion Before Liver Transplantation
    Muller, Xavier
    Schlegel, Andrea
    Kron, Philipp
    Eshmuminov, Dilmurodjon
    Wuerdinger, Michael
    Meierhofer, David
    Clavien, Pierre-Alain
    Dutkowski, Philipp
    ANNALS OF SURGERY, 2019, 270 (05) : 783 - 790
  • [9] Impact of Hypothermic Oxygenated Machine Perfusion on Hepatocellular Carcinoma Recurrence after Liver Transplantation
    Rigo, Federica
    De Stefano, Nicola
    Patrono, Damiano
    De Donato, Victor
    Campi, Ludovico
    Turturica, Diana
    Doria, Teresa
    Sciannameo, Veronica
    Berchialla, Paola
    Tandoi, Francesco
    Romagnoli, Renato
    JOURNAL OF PERSONALIZED MEDICINE, 2023, 13 (05):
  • [10] Comment on "Novel Real-time Prediction of Liver Graft Function During Hypothermic Oxygenated Machine Perfusion Before Liver Transplantation''
    Patrono, Damiano
    Sofia, Silvia
    Caropreso, Paola
    Catalano, Giorgia
    Rizza, Giorgia
    Mazza, Elena
    Mengozzi, Giulio
    Romagnoli, Renato
    ANNALS OF SURGERY, 2021, 274 (06) : E686 - E688