Quantitative Accuracy of Reconstruction Methods in Preclinical PET and Effects on Kinetic Modelling

被引:0
|
作者
Turmacu, V. [1 ]
Salvi de Souza, G. [1 ,2 ]
Garcia-Varela, L. [3 ]
Doorduin, J. [1 ]
Luurtsema, G. [1 ]
Tsoumpas, C. [1 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Dept Nucl Med & Mol Imaging, Groningen, Netherlands
[2] Pontificia Univ Catolica Rio Grande do Sul, Sch Med, Porto Alegre, RS, Brazil
[3] Univ Hosp Santiago de Compostela, Hlth Res Inst Santiago de Compostela IDIS, Nucl Med & Mol Imaging Grp, Santiago De Compostela, Spain
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
EP-0821
引用
收藏
页码:S759 / S760
页数:2
相关论文
共 50 条
  • [1] Quantitative accuracy of preclinical in ovo PET/MRI: influence of attenuation and quantification methods
    Balber, Theresa
    Bencurova, Katarina
    Mayrhofer, Manuela
    Friske, Joachim
    Haas, Martin
    Kuntner, Claudia
    Helbich, Thomas H.
    Hacker, Marcus
    Mitterhauser, Markus
    Rausch, Ivo
    EJNMMI PHYSICS, 2025, 12 (01):
  • [2] Comparison of reconstruction methods and quantitative accuracy in Siemens Inveon PET scanner
    Yu, A. Ram
    Kim, Jin Su
    Kang, Joo Hyun
    Lim, Sang Moo
    JOURNAL OF INSTRUMENTATION, 2015, 10
  • [3] Optimizing modelling in iterative image reconstruction for preclinical pinhole PET
    Goorden, Marlies C.
    van Roosmalen, Jarno
    van der Have, Frans
    Beekman, Freek J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (10): : 3712 - 3733
  • [4] Evaluating Reconstruction Parameter for Improving Quantitative Accuracy in PET
    Saha, K.
    Cheney, C.
    MEDICAL PHYSICS, 2022, 49 (06) : E659 - E660
  • [5] Clinical validation of the use of iterative reconstruction (OSEM) for dynamic quantitative PET studies: Quantitative accuracy and effect on kinetic modeling.
    Boellaard, R
    Weerdt, AP
    Klein, LJ
    Blok, JJ
    Kluizenaar, M
    Lammertsma, AA
    JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (05) : 59P - 59P
  • [6] Quantitative accuracy of PET for image-based kinetic analysis
    Seo, Youngho
    Teo, Boon-Keng
    Hadi, Mohiuddin
    Schreck, Carole
    Bacharach, Stephen L.
    Hasegawa, Bruce H.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3601 - 3604
  • [7] Quantitative accuracy of PET/CT for image-based kinetic analysis
    Seo, Youngho
    Teo, Boon-Keng
    Hadi, Mohiuddin
    Schreck, Carole
    Bacharach, Stephen L.
    Hasegawa, Bruce H.
    MEDICAL PHYSICS, 2008, 35 (07) : 3086 - 3089
  • [8] Quantitative accuracy of MAP reconstruction for dynamic PET imaging in small animals
    Cheng, Ju-Chieh
    Shoghi, Kooresh
    Laforest, Richard
    MEDICAL PHYSICS, 2012, 39 (02) : 1029 - 1041
  • [9] TOF reconstruction for improved quantitative accuracy in PET/CT studies with misalignment
    Bai, Chuanyong
    Andreyev, Andriy
    Hu, Zhiqiang
    Maniawski, Piotr
    Zhang, Jun
    Knopp, Michael
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57
  • [10] Experimental and clinical evaluation of iterative reconstruction (OSEM) in dynamic PET: Quantitative characteristics and effects on kinetic modeling
    Boellaard, R
    van Lingen, A
    Lammertsma, AA
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (05) : 808 - 817