Towards AI-enabled minimum dose CBCT-based synthetic CT: dose calculation and contouring accuracy

被引:0
|
作者
Chan, Yan Chi Ivy [1 ]
Li, Minglun [1 ,2 ]
Thummerer, Adrian [1 ]
Parodi, Katia [3 ]
Belka, Claus [1 ,4 ,5 ]
Kurz, Christopher [1 ]
Landry, Guillaume [1 ]
机构
[1] Ludwig Maximilians Univ Munchen, LMU Univ Hosp, Dept Radiat Oncol, Munich, Germany
[2] Lueneburg Hosp, Dept Radiat Oncol, Luneburg, Germany
[3] Ludwig Maximilians Univ Munchen, Dept Med Phys, Fac Phys, Garching, Germany
[4] German Canc Consortium DKTK, Partner Site Munich, Munich, Germany
[5] BZKF, Bavarian Canc Res Ctr, Munich, Germany
关键词
low dose CBCT; deep learning; synthetic CT;
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
737
引用
收藏
页码:S3794 / S3798
页数:5
相关论文
共 50 条
  • [1] Generate Synthetic CT From Cone Beam CT for CBCT-Based Dose Calculation
    Wang, H.
    Barbee, D.
    Wang, W.
    Pennell, R.
    Hu, K.
    Osterman, K.
    MEDICAL PHYSICS, 2016, 43 (06) : 3432 - 3432
  • [2] Comparison of CT number calibration techniques for CBCT-based dose calculation
    Dunlop, Alex
    McQuaid, Dualta
    Nill, Simeon
    Murray, Julia
    Poludniowski, Gavin
    Hansen, Vibeke N.
    Bhide, Shreerang
    Nutting, Christopher
    Harrington, Kevin
    Newbold, Kate
    Oelfke, Uwe
    STRAHLENTHERAPIE UND ONKOLOGIE, 2015, 191 (12) : 970 - 978
  • [3] Evaluation of CBCT-Based Dose Calculation in an Enhanced CBCT System
    Yoon, K.
    Cho, I.
    Kwak, J.
    Cho, B.
    Kim, Y.
    Ahn, S.
    Lee, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S861 - S861
  • [4] A Critical Look at CBCT-Based Dose Calculation Accuracy as It Is Applied to Adaptive Radiotherapy
    Buele, A. Bejarano
    Sperling, N.
    Parsai, E.
    MEDICAL PHYSICS, 2016, 43 (06) : 3346 - 3346
  • [5] Online CBCT-based proton range and dose calculation
    Kurz, C.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S454 - S455
  • [6] Feasibility of MV CBCT-based treatment planning for urgent radiation therapy: dosimetric accuracy of MV CBCT-based dose calculations
    Held, Mareike
    Sneed, Penny K.
    Fogh, Shannon E.
    Pouliot, Jean
    Morin, Olivier
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (06): : 458 - 471
  • [7] Assessment of CBCT-based synthetic CT generation accuracy for adaptive radiotherapy planning
    O'Hara, Christopher J.
    Bird, David
    Al-Qaisieh, Bashar
    Speight, Richard
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (11):
  • [8] FEASIBILITY OF CBCT-BASED DOSE CALCULATION: COMPARISON OF THREE HU ADJUSTMENT TECHNIQUES
    Fotina, I.
    Hopfgartner, J.
    Stock, M.
    Steininger, T.
    Georg, D.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S150 - S151
  • [9] Feasibility of CBCT-based dose calculation: Comparative analysis of HU adjustment techniques
    Fotina, Irina
    Hopfgartner, Johannes
    Stock, Markus
    Steininger, Thomas
    Luetgendorf-Caucig, Carola
    Georg, Dietmar
    RADIOTHERAPY AND ONCOLOGY, 2012, 104 (02) : 249 - 256
  • [10] CBCT-based calculation of the dose to target for all fractions in prostate cancer radiotherapy
    Havelund, Rasmus
    Berg, Martin
    Thing, Rune S.
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S4101 - S4105