3 MV accelerator mass spectrometry measurements of 36Cl using the Isobar Separator for Anions

被引:0
|
作者
Flannigan, Erin L. [1 ,2 ,6 ]
Kieser, William E. [2 ,3 ]
Crann, Carley A. [1 ,4 ,7 ]
Vockenhuber, Christof [5 ]
Francisco, Barbara B. A. [1 ,4 ]
机构
[1] Univ Ottawa, AE Lalonde AMS Lab, 25 Templeton St, Ottawa, ON K1N 6N5, Canada
[2] Univ Ottawa, Dept Phys, 150 Louis Pasteur Pvt, Ottawa, ON K1N 6N5, Canada
[3] Isobarex Corp, 60 Equator Crescent, Vaughan, ON L6A 2Y9, Canada
[4] Univ Ottawa, Dept Earth & Environm Sci, 25 Templeton St, Ottawa, ON K1N 6N5, Canada
[5] Swiss Fed Inst Technol, Lab Ion Beam Phys, CH-8093 Zurich, Switzerland
[6] Rutherford Appleton Lab, STFC, ISIS Pulsed Spallat Neutron & Muon Facil, Harwell OX11 0QX, England
[7] Canadian Nucl Safety Commiss, 280 Slater St, Ottawa, ON K1P 5S9, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Accelerator mass spectrometry; Isobar separation; Ion-gas reactions; Ion beam cooler; Radio-frequency quadrupole; Chlorine-36; AMS MEASUREMENTS; CL-36; PERFORMANCE; FACILITY; ASTER; UNIVERSITY; CHEMISTRY; CHLORINE; MAGNET; SYSTEM;
D O I
10.1016/j.ijms.2025.117433
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
A second low-energy injection line containing the Isobar Separator for Anions (ISA), a radiofrequency quadrupole reaction cell system, was installed on the 3 MV tandem accelerator system at the A. E. Lalonde (AEL) accelerator mass spectrometry (AMS) Laboratory. The suppression of 36S via anion-gas reaction with NO2 was evaluated for measurements of 36Cl reference materials and a dilution series, using a 3 MV AMS system. The dilution series, with 36Cl/Cl ratios ranging from 10-11 to 10-15, were measured in comparison with external measurement. 36Cl/Cl blank levels of (7 +/- 4) x10-15 were reached. While ISA-AMS is not currently able to achieve sufficient separation for most 36Cl applications, these measurements show progress towards routine measurement of 36Cl and demonstrate the steps required to validate such measurements on lower energy AMS systems.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Isobar suppression for 36Cl accelerator mass spectrometry at the University of Tsukuba
    Hosoya, Seiji
    Sasa, Kimikazu
    Takahashi, Tsutomu
    Matsunaka, Tetsuya
    Matsumura, Masumi
    Shen, Hongtao
    Ota, Yuki
    Takano, Kenta
    Ochiai, Yuta
    Sueki, Keisuke
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2019, 438 : 131 - 135
  • [2] Isobar Attenuation Using Anion-Gas Reactions for Accelerator Mass Spectrometry and Application to 36Cl
    Eliades, John
    Zhao, Xiaolei
    Kieser, William E.
    Litherland, Albert E.
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2010, 34 (02) : 107 - 115
  • [3] 36Cl accelerator mass spectrometry with a bespoke instrument
    Wilcken, K. M.
    Freeman, S. P. H. T.
    Schnabel, C.
    Binnie, S. A.
    Xu, S.
    Phillips, R. J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2013, 294 : 107 - 114
  • [4] High temperature pyrolysis to extract 36Cl for Accelerator Mass Spectrometry measurements
    Chalk River Lab, Chalk River, Canada
    Nucl Instrum Methods Phys Res Sect B, 4 (436-440):
  • [5] AMS of 36Cl with the VERA 3 MV tandem accelerator
    Martschini, Martin
    Andersson, Pontus
    Forstner, Oliver
    Golser, Robin
    Hanstorp, Dag
    Lindahl, Anton O.
    Kutschera, Walter
    Pavetich, Stefan
    Priller, Alfred
    Rohlen, Johan
    Steier, Peter
    Suter, Martin
    Wallner, Anton
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2013, 294 : 115 - 120
  • [6] Ultra-trace analysis of 36Cl by accelerator mass spectrometry: an interlaboratory study
    Merchel, S.
    Bremser, W.
    Alfimov, V.
    Arnold, M.
    Aumaitre, G.
    Benedetti, L.
    Bourles, D. L.
    Caffee, M.
    Fifield, L. K.
    Finkel, R. C.
    Freeman, S. P. H. T.
    Martschini, M.
    Matsushi, Y.
    Rood, D. H.
    Sasa, K.
    Steier, P.
    Takahashi, T.
    Tamari, M.
    Tims, S. G.
    Tosaki, Y.
    Wilcken, K. M.
    Xu, S.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 400 (09) : 3125 - 3132
  • [7] Decadal 10Be, 26Al and 36Cl QA measurements on the SUERC 5 MV accelerator mass spectrometer
    Xu, Sheng
    Freeman, Stewart P. H. T.
    Rood, Dylan H.
    Shanks, Richard P.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2015, 361 : 39 - 42
  • [8] ACCELERATOR MASS SPECTROMETRY OF 36Cl, 129I AND 187Os.
    Kubik, P.W.
    Elmore, D.
    Fehn, U.
    Phillips, F.M.
    Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms, 1986, B24-25 (pt 2 Apr III) : 676 - 681
  • [9] Ultra-trace analysis of 36Cl by accelerator mass spectrometry: an interlaboratory study
    S. Merchel
    W. Bremser
    V. Alfimov
    M. Arnold
    G. Aumaître
    L. Benedetti
    D. L. Bourlès
    M. Caffee
    L. K. Fifield
    R. C. Finkel
    S. P. H. T. Freeman
    M. Martschini
    Y. Matsushi
    D. H. Rood
    K. Sasa
    P. Steier
    T. Takahashi
    M. Tamari
    S. G. Tims
    Y. Tosaki
    K. M. Wilcken
    S. Xu
    Analytical and Bioanalytical Chemistry, 2011, 400 : 3125 - 3132
  • [10] Accelerator mass spectrometry measurement of the reaction 35Cl(n, γ)36Cl at keV energies
    Pavetich, Stefan
    Wallner, Anton
    Martschini, Martin
    Akhmadaliev, Shavkat
    Dillmann, Iris
    Fifield, Keith
    Halfon, Shlomi
    Heftrich, Tanja
    Kaeppeler, Franz
    Lederer-Woods, Claudia
    Merchel, Silke
    Paul, Michael
    Reifarth, Rene
    Rugel, Georg
    Steier, Peter
    Tessler, Moshe
    Tims, Stephen
    Weigand, Mario
    Weissman, Leo
    PHYSICAL REVIEW C, 2019, 99 (01)