Dosimetric characterization of range shifter-modulated proton beam in the presence of magnetic field

被引:0
|
作者
Cobanaj, Marisa [1 ,2 ,3 ]
Gebauer, Benjamin [1 ,2 ,3 ]
Lebbink, Franciska [1 ,2 ,4 ,5 ,6 ,7 ,8 ,9 ]
Oborn, Brad [10 ]
Pawelke, Joerg [1 ,2 ,3 ]
Luehr, Armin [11 ]
Hoffmann, Aswin [1 ,2 ,3 ,9 ]
机构
[1] Tech Univ Dresden, Helmholtz Zentrum Dresden Rossendorf, OncoRay Natl Ctr Radiat Res Oncol, Fac Med, Dresden, Germany
[2] Tech Univ Dresden, Helmholtz Zentrum Dresden Rossendorf, Univ Hosp Carl Gustav Carus, Dresden, Germany
[3] Helmholtz Zentrum Dresden Rossendorf, Inst Radiooncol OncoRay, Dresden, Germany
[4] Natl Ctr Tumor Dis NCT UCC, Dresden, Germany
[5] German Canc Res Ctr, Heidelberg, Germany
[6] Tech Univ Dresden, Fak Med, Dresden, Germany
[7] Tech Univ Dresden, Univ Hosp Carl Gustav Carus, Dresden, Germany
[8] Helmholtz Zentrum Dresden Rossendorf HZDR, Dresden, Germany
[9] Tech Univ Dresden, Helmholtz Zentrum Dresden Rossendorf, Dept Radiotherapy & Radiat Oncol, Fac Med, Dresden, Germany
[10] Illawarra Canc Care Ctr ICCC, Wollongong, NSW 2500, Australia
[11] TU Dortmund Univ, Dept Phys, Dortmund, Germany
关键词
MRiPT; RS; spot size; dosimetry; EBT3;
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
1167
引用
收藏
页码:S3235 / S3239
页数:5
相关论文
共 50 条
  • [1] Experimental dosimetric characterization of a proton beam in the presence of a magnetic field
    Cabal, F. Padilla
    Fetty, L.
    Kuess, P.
    Georg, D.
    Fuchs, H.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S298 - S298
  • [2] Experimental dosimetric characterization of proton pencil beam distortion in a perpendicular magnetic field of an in-beam MR scanner
    Gebauer, Benjamin
    Pawelke, Joerg
    Hoffmann, Aswin
    Luehr, Armin
    MEDICAL PHYSICS, 2023, 50 (11) : 7294 - 7303
  • [3] Commissioning and Dosimetric Assessment of a Range Shifter Helmet as An Energy Absorber Device for Scanning Beam Proton Therapy
    Allred, B.
    Mundy, D.
    Furutani, K.
    Beltran, C.
    Saunders, A.
    Patel, S.
    Rwigema, J.
    Shen, J.
    Robertson, D.
    Lara, P.
    McGee, L.
    Bues, M.
    Anand, A.
    MEDICAL PHYSICS, 2019, 46 (06) : E598 - E598
  • [4] Commissioning and Evaluation of Extended Range Shifter for Synchrotron Based Intensity Modulated Proton Beam System
    Moskvin, V.
    Faught, A.
    MEDICAL PHYSICS, 2019, 46 (06) : E599 - E599
  • [5] Dosimetric feasibility of intensity modulated proton therapy in a transverse magnetic field of 1.5 Tesla
    Hartman, J.
    Kontaxis, C.
    Bol, G. H.
    Lagendijk, J. J. W.
    Van Vulpen, M.
    Raaymakers, B. W.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S79 - S80
  • [6] Dosimetric feasibility of intensity modulated proton therapy in a transverse magnetic field of 1.5 T
    Hartman, J.
    Kontaxis, C.
    Bol, G. H.
    Frank, S. J.
    Lagendijk, J. J. W.
    van Vulpen, M.
    Raaymakers, B. W.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (15): : 5955 - 5969
  • [7] Impact of range shifter material on proton pencil beam spot characteristics
    Shen, Jiajian
    Liu, Wei
    Anand, Aman
    Stoker, Joshua B.
    Ding, Xiaoning
    Fatyga, Mirek
    Herman, Michael G.
    Bues, Martin
    MEDICAL PHYSICS, 2015, 42 (03) : 1335 - 1353
  • [8] Magnetic field of a proton pencil beam as range verification method: The impact of secondaries
    Raedler, M.
    Buizza, G.
    Palaniappan, P.
    Gianoli, C.
    Baroni, G.
    Paganelli, C.
    Parodi, K.
    Riboldi, M.
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S792 - S793
  • [9] Should the Machine-Related Range Shifter (MRS) Be Replaced by a Patient-Related Range Shifter (PRS) to Preserve the Scanning Beam Dosimetric Advantages?
    Lin, H.
    Shen, J.
    McDonough, J.
    Tochner, Z.
    Both, S.
    MEDICAL PHYSICS, 2015, 42 (06) : 3495 - 3496
  • [10] 2D dosimetric impact of an in-beam MR magnetic field on scanned proton pencil beam spot fields
    Gebauer, B.
    Pawelke, J.
    Hoffmann, A.
    Luhr, A.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S188 - S189