Effects of epileptic seizures on the quality of biosignals recorded from wearables

被引:0
|
作者
Boettcher, Sebastian [1 ,2 ]
Zabler, Nicolas [1 ,2 ]
Jackson, Michele [3 ]
Bruno, Elisa [4 ]
Biondi, Andrea [4 ]
Epitashvili, Nino [1 ]
Vieluf, Solveig [3 ,5 ,6 ]
Duempelmann, Matthias [1 ,2 ]
Richardson, Mark P. [4 ]
Brinkmann, Benjamin H. [7 ]
Loddenkemper, Tobias [3 ]
Schulze-Bonhage, Andreas [1 ]
机构
[1] Univ Freiburg, Univ Med Ctr, Epilepsy Ctr, Freiburg, Germany
[2] Univ Freiburg, Dept Microsyst Engn IMTEK, Freiburg, Germany
[3] Harvard Med Sch, Boston Childrens Hosp, Div Epilepsy & Clin Neurophysiol, Boston, MA USA
[4] Kings Coll London, Inst Psychiat Psychol & Neurosci, Dept Basic & Clin Neurosci, London, England
[5] Ludwig Maximilians Univ Munchen, LMU Univ Hosp, Dept Med 1, Munich, Germany
[6] German Ctr Cardiovasc Res, Partner Site Munich Heart Alliance, Munich, Germany
[7] Mayo Clin, Dept Neurol & Physiol & Biomed Engn, Rochester, MN USA
基金
美国国家卫生研究院; 欧盟地平线“2020”;
关键词
data quality; epilepsy; seizure detection; signal quality; INTERNATIONAL LEAGUE; AUTOMATED SEIZURE; SYSTEMS;
D O I
10.1111/epi.18138
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
ObjectiveWearable nonelectroencephalographic biosignal recordings captured from the wrist offer enormous potential for seizure monitoring. However, signal quality remains a challenging factor affecting data reliability. Models trained for seizure detection depend on the quality of recordings in peri-ictal periods in performing a feature-based separation of ictal periods from interictal periods. Thus, this study aims to investigate the effect of epileptic seizures on signal quality, ensuring accurate and reliable monitoring.MethodsThis study assesses the signal quality of wearable data during peri-ictal phases of generalized tonic-clonic and focal to bilateral tonic-clonic seizures (TCS), focal motor seizures (FMS), and focal nonmotor seizures (FNMS). We evaluated accelerometer (ACC) activity and the signal quality of electrodermal activity (EDA) and blood volume pulse (BVP) data. Additionally, we analyzed the influence of peri-ictal movements as assessed by ACC (ACC activity) on signal quality and examined intraictal subphases of focal to bilateral TCS.ResultsWe analyzed 386 seizures from 111 individuals in three international epilepsy monitoring units. BVP signal quality and ACC activity levels differed between all seizure types. We found the largest decrease in BVP signal quality and increase in ACC activity when comparing the ictal phase to the pre- and postictal phases for TCS. Additionally, ACC activity was strongly negatively correlated with BVP signal quality for TCS and FMS, and weakly for FNMS. Intraictal analysis revealed that tonic and clonic subphases have the lowest BVP signal quality and the highest ACC activity.SignificanceMotor elements of seizures significantly impair BVP signal quality, but do not have significant effect on EDA signal quality, as assessed by wrist-worn wearables. The results underscore the importance of signal quality assessment methods and careful selection of robust modalities to ensure reliable seizure detection. Future research is needed to explain whether seizure detection models' decisions are based on signal responses induced by physiological processes as opposed to artifacts.
引用
收藏
页码:3513 / 3525
页数:13
相关论文
共 50 条
  • [1] PROPAGATION PATTERNS OF EPILEPTIC SEIZURES RECORDED FROM INTRACEREBRAL ELECTRODES
    GOTMAN, J
    GLOOR, P
    OLIVIER, A
    QUESNEY, LF
    EPILEPSIA, 1983, 24 (04) : 518 - 518
  • [2] SURFACE EMG RECORDED DURING GENERALIZED EPILEPTIC SEIZURES
    Beniczky, S.
    Hansen, C.
    Alving, J.
    Wolf, P.
    EPILEPSIA, 2009, 50 : 184 - 185
  • [3] Personalized Stress Detection Using Biosignals from Wearables: A Scoping Review
    Bolpagni, Marco
    Pardini, Susanna
    Dianti, Marco
    Gabrielli, Silvia
    SENSORS, 2024, 24 (10)
  • [4] An automatic warning system for epileptic seizures recorded on intracerebral EEGs
    Grewal, S
    Gotman, J
    CLINICAL NEUROPHYSIOLOGY, 2005, 116 (10) : 2460 - 2472
  • [5] The quality of life of a child with epileptic seizures
    Martynyuk, VU
    Zinchenko, SN
    Beryzhnoy, AB
    Kharytonov, VI
    EPILEPSIA, 2003, 44 : 192 - 192
  • [6] SPATIOTEMPORAL EEG MEASURES AND THEIR APPLICATION TO HUMAN INTRACRANIALLY RECORDED EPILEPTIC SEIZURES
    DARCEY, TM
    WILLIAMSON, PD
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1985, 61 (06): : 573 - 587
  • [7] A method to quantify invariant information in depth-recorded epileptic seizures
    Wendling, F
    Badier, JM
    Chauvel, P
    Coatrieux, JL
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1997, 102 (06): : 472 - 485
  • [8] Autonomic epileptic seizures, autonomic effects of seizures, and SUDEP
    Moseley, Brian
    Bateman, Lisa
    Millichap, John J.
    Wirrell, Elaine
    Panayiotopoulos, Chrysostomos P.
    EPILEPSY & BEHAVIOR, 2013, 26 (03) : 375 - 385
  • [9] Patient and caregiver quality of life in psychogenic non-epileptic seizures compared to epileptic seizures
    Karakis, Ioannis
    Montouris, Georgia D.
    Piperidou, Charitomeni
    San Luciano, Marta
    Meador, Kimford J.
    Cole, Andrew J.
    SEIZURE-EUROPEAN JOURNAL OF EPILEPSY, 2014, 23 (01): : 47 - 54
  • [10] Using Machine Learning to Augment Differentiation of Epileptic and Psychogenic Non-Epileptic Seizures Recorded with sEMG
    Cardenas, Damon
    Whitmire, Luke
    Halford, Jonathan
    NEUROLOGY, 2020, 94 (15)