Optimization of Coaxial Borehole Heat Exchanger for Hot Wet Climates: Experimental and Numerical Approaches

被引:0
|
作者
Kahwaji, Ghalib Y. [1 ]
Ali, Muhannad T. [1 ]
Boudekji, Giada [2 ]
Capuano, Davide [2 ]
Samaha, Mohamed A. [1 ,3 ]
机构
[1] Rochester Inst Technol Dubai, Dept Mech & Ind Engn, Dubai 341055, U Arab Emirates
[2] Graded SpA, I-80141 Naples, Italy
[3] Rochester Inst Technol, Extended Fac, Sch Math & Stat, Rochester, NY 14623 USA
关键词
Numerical Analysis; Permeability; Cooling Technology; Coefficient of Performance; Heating; Ventilating; and Air Conditioning; Geothermal Energy; Experimental Heat Transfer and Fluid Dynamics; Borehole Heat Exchangers; Boundary Layer Analysis; Coupled Conduction-Convection Investigation; TRANSFER PERFORMANCE; THERMAL PERFORMANCE; PUMP; MODEL;
D O I
10.2514/1.T7143
中图分类号
O414.1 [热力学];
学科分类号
摘要
In a previous study (Kahwaji et al., Heat Transfer, Vol. 53, No. 3, 2024, pp. 1474-1500), a numerical analysis was employed to optimize the performance of a ground borehole heat exchanger (BHE). Following the analysis, both experimental and numerical studies are conducted here to investigate the performance, efficacy, and feasibility of BHE to be utilized as a sustainable heat rejection method to reduce power consumption in air-conditioning (A/C) systems employed in hot and humid climates. An experimental setup is established, for the first time in Dubai, with five BHEs made of coaxial tube configuration with insulated inner pipe. The boreholes are drilled with 40 m depth and 0.09 m outside diameter. A water-cooled A/C system is selected and connected to the BHEs to provide a heat rejection load. An identical air-cooled A/C system with the same cooling load is installed for comparison. The time-dependent water-side pressure, temperature, flow rate, and power consumptions are measured under different experimental conditions. Additionally, the soil-side temperature, porosity, and permeability are measured at different depths. For validation, optimization, and deep investigation of the performance of the BHE, a numerical model simulating the system is developed. A couple of correlations and physical findings related to water and soil temperature distributions, heat rejection, and power saving are obtained. The BHE is proved to be effective in saving energy up to similar to 20% at high ambient temperature periods and an average of 6-11.7% during the daytime, demonstrating the efficacy and feasibility of the system.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Numerical study on the heat performance of enhanced coaxial borehole heat exchanger and double U borehole heat exchanger
    Chen, Ke
    Zheng, Jia
    Li, Juan
    Shao, Jingli
    Zhang, Qiulan
    APPLIED THERMAL ENGINEERING, 2022, 203
  • [2] Transient numerical model for a coaxial borehole heat exchanger with the effect of borehole heat capacity
    Yang, Xinyu
    Wang, Guodong
    Wang, Qingsheng
    Chen, Changqi
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2019, 43 (12) : 6551 - 6560
  • [3] Numerical study on the heat transfer performance of coaxial shallow borehole heat exchanger
    Li G.
    Yang J.
    Zhu X.
    Shen Z.
    Energy and Built Environment, 2021, 2 (04): : 445 - 455
  • [4] Experimental and analytical investigation on pipe sizes for a coaxial borehole heat exchanger
    Gordon, David
    Bolisetti, Tirupati
    Ting, David S-K.
    Reitsma, Stanley
    RENEWABLE ENERGY, 2018, 115 : 946 - 953
  • [5] Field Test and Numerical Simulation on Heat Transfer Performance of Coaxial Borehole Heat Exchanger
    Li, Peng
    Guan, Peng
    Zheng, Jun
    Dou, Bin
    Tian, Hong
    Duan, Xinsheng
    Liu, Hejuan
    ENERGIES, 2020, 13 (20)
  • [6] Transient heat transfer in a coaxial borehole heat exchanger
    Beier, Richard A.
    Acuna, Jose
    Mogensen, Paine
    Palm, Bjorn
    GEOTHERMICS, 2014, 51 : 470 - 482
  • [7] EVALUATION OF A COAXIAL BOREHOLE HEAT EXCHANGER PROTOTYPE
    Acuna, Jose
    Mogensen, Palne
    Palm, Bjorn
    PROCEEDINGS OF THE ASME INTERNATIONAL HEAT TRANSFER CONFERENCE - 2010, VOL 4: HEAT TRANSFER MEASUREMENT TECHNIQUES, HEAT TRANSFER EQUIPMENT, THERMOELECTRICS, 2010, : 343 - 350
  • [8] Transient numerical simulation of the coaxial borehole heat exchanger with the different diameters ratio
    Iry, Soleiman
    Rafee, Roohollah
    GEOTHERMICS, 2019, 77 : 158 - 165
  • [9] Study on the Influence of Borehole Heat Capacity on Deep Coaxial Borehole Heat Exchanger
    Wang, Changlong
    Fang, Han
    Wang, Xin
    Lu, Jinli
    Sun, Yanhong
    SUSTAINABILITY, 2022, 14 (04)
  • [10] Experimental study on geotechnical thermal response test of coaxial borehole heat exchanger
    Guan P.
    Duan X.
    Jiao Y.
    Li P.
    Tan F.
    Zou J.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2022, 43 (02): : 55 - 61