Comprehensive In Vitro and In Silico Aerodynamic Analysis of High-Dose Ibuprofen- and Mannitol-Containing Dry Powder Inhalers for the Treatment of Cystic Fibrosis

被引:0
|
作者
Party, Petra [1 ]
Piszman, Zsofia Ilona [1 ]
Farkas, Arpad [2 ]
Ambrus, Rita [1 ]
机构
[1] Univ Szeged, Inst Pharmaceut Technol & Regulatory Affairs, Eotvos St 6, H-6720 Szeged, Hungary
[2] Hungarian Acad Sci, Ctr Energy Res, Konkoly Thege Miklos St 29 33, H-1121 Budapest, Hungary
关键词
dry powder inhaler; mannitol; ibuprofen; wet milling; spray drying; Andersen Cascade Impactor; stochastic lung model; cystic fibrosis; SPRAY-DRIED MANNITOL; PULMONARY DELIVERY; L-LEUCINE; FORMULATION; DRUG; PERFORMANCE; EXCIPIENTS; INHALATION; DEPOSITION; CARRIER;
D O I
10.3390/pharmaceutics16111465
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Background: Cystic fibrosis is a hereditary disease, which causes the accumulation of dense mucus in the lungs accompanied by frequent local inflammation. The non-steroidal anti-inflammatory drug ibuprofen (IBU) and the mucolytic mannitol (MAN) can treat these symptoms. Compared to per os administration, a lower dose of these drugs is sufficient to achieve the desired effect by delivering them in a pulmonary manner. However, it is still a challenge to administer high drug doses to the lungs. We aim to develop two inhaled powder formulations, a single-drug product of MAN and a combined formulation containing IBU and MAN. Methods: MAN was dissolved in an aqueous solution of Poloxamer-188 (POL). In the case of the combined formulation, a suspension was first prepared in a planetary mill via wet milling in POL medium. After the addition of leucine (LEU), the formulations were spray-dried. The prepared DPI samples were analyzed by using laser diffraction, scanning electron microscopy, powder X-ray diffraction, differential scanning calorimetry, density tests, in vitro aerodynamic studies (Andersen Cascade Impactor, Spraytec (R) device), in vitro dissolution tests in artificial lung fluid, and in silico tests with stochastic lung model. Results: The DPIs showed suitability for inhalation with low-density spherical particles of appropriate size. The LEU-containing systems were characterized by high lung deposition and adequate aerodynamic diameter. The amorphization during the procedures resulted in rapid drug release. Conclusions: We have successfully produced a single-drug formulation and an innovative combination formulation, which could provide complex treatment for patients with cystic fibrosis to improve their quality of life.
引用
收藏
页数:18
相关论文
共 3 条