Improved microbial water quality and ozone performance following coagulation: implications for carbon based advanced treatment for potable reuse

被引:1
|
作者
Morrison, Christina M. [1 ]
Atkinson, Ariel J. [1 ]
Gerrity, Daniel [1 ]
Wert, Eric C. [1 ]
机构
[1] Southern Nevada Water Author, POB 99954, Las Vegas, NV 89193 USA
关键词
HEPATITIS-A VIRUS; DRINKING-WATER; WASTE-WATER; FLOW-CYTOMETRY; CRYPTOSPORIDIUM-OOCYSTS; ESCHERICHIA-COLI; VEGETATIVE CELLS; OZONATION; REMOVAL; BACILLUS;
D O I
10.1039/d4ew00638k
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
To facilitate broader implementation of potable reuse, it is important to fully account for pathogen log10 reduction values (LRVs), including unit processes that are historically uncredited or under-credited. Despite its potential for pathogen removal, coagulation coupled with flocculation (C/F) has historically been omitted or overlooked when pursuing credits for potable reuse. However, with greater implementation of carbon-based advanced treatment (CBAT), which utilizes a combination of ozone, biofiltration, and granular activated carbon treatment as an alternative to membrane treatment (i.e., reverse osmosis), C/F may emerge as a valuable unit process for achieving improvements in water quality, operational performance, and public health protection in potable reuse systems. This study evaluated the ability of C/F with ferric chloride to improve both bulk and microbial water quality of secondary wastewater effluent and improve downstream ozone performance. This study also evaluated potential surrogates for microbial removal during C/F treatment. C/F removed 17-54% of DOC with ferric doses ranging from 10-50 mg Fe per L, with 30 mg Fe per L sufficient for meeting TOC removal requirements from the Stage 1 D/DBPR for all evaluated secondary effluents. Coagulant doses of 30 mg Fe per L obtained LRVs ranging from 2-3 for MS2 and B. subtilis spores. MS2 and B. subtilis spore removal exhibited strong (r >= 0.8) and significant (p < 0.05) Pearson's correlation with the removal of intact cell counts and total cell counts via flow cytometry (FCM), DOC, total adenosine triphosphate (ATP), and intracellular ATP. C/F immediately preceding ozone treatment improved inactivation of B. subtilis spores, lowered applied ozone doses, and increased ozone exposure (Ct) for similar specific ozone doses as compared to secondary effluent without C/F pre-treatment. Overall, C/F with ferric chloride was determined to be a valuable treatment step for removal of dissolved organic matter, MS2 bacteriophage, B. subtilis spores, and improvement of downstream ozone treatment. Furthermore, FCM, ATP, and DOC were determined to be strong potential candidates as surrogates for microorganism removal during C/F treatment, although further testing with pathogens is still necessary to justify LRV crediting.
引用
收藏
页码:3158 / 3171
页数:14
相关论文
共 17 条
  • [1] Extended field investigations of ozone-biofiltration advanced water treatment for potable reuse
    Sundaram, Vijay
    Pagilla, Krishna
    Guarin, Tatiana
    Li, Lin
    Marfil-Vega, Ruth
    Bukhari, Zia
    WATER RESEARCH, 2020, 172 (172)
  • [2] Relating microbial community composition to treatment performance in an ozone-biologically active carbon filtration potable reuse treatment train
    Blair, Matthew F.
    Vaidya, Ramola
    Salazar-Benites, Germano
    Bott, Charles B.
    Pruden, Amy
    WATER RESEARCH, 2024, 262
  • [3] Process benefits of ozone/BAC as pretreatment to membrane-based advanced treatment for direct potable reuse
    Trussell, R. Shane
    Pisarenko, Aleksey N.
    WATER REUSE, 2024, 14 (02) : 146 - 159
  • [4] Rationale for constant flow to optimize wastewater treatment and advanced water treatment performance for potable reuse applications
    Tchobanoglous, George
    Kenny, John
    Leverenz, Harold
    WATER ENVIRONMENT RESEARCH, 2021, 93 (08) : 1231 - 1242
  • [5] Drivers of Microbial Risk for Direct Potable Reuse and de Facto Reuse Treatment Schemes: The Impacts of Source Water Quality and Blending
    Chaudhry, Rabia M.
    Hamilton, Kerry A.
    Haas, Charles N.
    Nelson, Kara L.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2017, 14 (06)
  • [6] Per- and polyfluoroalkyl substance removal in carbon-based advanced treatment for potable reuse
    Kumar, Pranjali
    Rodriguez-Gonzalez, Laura
    Salveson, Andrew
    Ammerman, David
    Steinle-Darling, Eva
    AWWA WATER SCIENCE, 2021, 3 (05):
  • [7] Combination of coagulation and adsorption technologies for advanced wastewater treatment for potable water reuse: By ANN, NSGA-II, and RSM
    Zahmatkesh, Sasan
    Karimian, Melika
    Chen, Zhijie
    Ni, Bing-Jie
    JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2024, 349
  • [8] Impacts of carbon-based advanced treatment processes on disinfection byproduct formation and speciation for potable reuse
    Peterson, Eric S.
    Johnson, Sierra
    Shiokari, Steven
    Yu, Yun
    Cook, Sherri M.
    Summers, R. Scott
    WATER RESEARCH, 2022, 220
  • [9] Tertiary treatment and dual disinfection to improve microbial quality of reclaimed water for potable and non-potable reuse: A case study of facilities in North Carolina
    Bailey, Emily S.
    Casanova, Lisa M.
    Simmons, Otto D., III
    Sobsey, Mark D.
    SCIENCE OF THE TOTAL ENVIRONMENT, 2018, 630 : 379 - 388
  • [10] Pathogen reduction by ozone-biological activated carbon-based advanced water reclamation for reuse
    Teel, Lydia
    Pagilla, Krishna
    Sundaram, Vijay
    Li, Lin
    Guarin, Tatiana
    Haak, Laura
    WATER ENVIRONMENT RESEARCH, 2022, 94 (05)