4D Reconstruction and Identification of Carotid Artery Stenosis Utilizing a Novel Pulsatile Ultrasound Phantom

被引:1
|
作者
Thurgood, Harrison [1 ]
Witte, Russell [2 ,3 ]
Laksari, Kaveh [1 ,2 ]
机构
[1] Univ Arizona, Dept Aerosp & Mech Engn, Tucson, AZ 85721 USA
[2] Univ Arizona, Dept Biomed Engn, Tucson, AZ 85721 USA
[3] Univ Arizona, Dept Med Imaging, Tucson, AZ USA
来源
CURRENT PROTOCOLS | 2021年 / 1卷 / 10期
基金
美国国家卫生研究院;
关键词
human carotid artery; phantom reconstruction; stenosis;
D O I
10.1002/cpz1.264
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
As a major application focus of vascular ultrasonography, the carotid artery has long been the subject of phantom design and procedure focus. It is therefore important to devise procedures that are minimally invasive and informative, initially using a physiologically accurate anthropomorphic phantom to validate the methodology. In this article, a novel phantom design protocol is presented that enables the efficient production of a pulsatile ultrasound phantom consisting of soft and vascular tissue mimics, as well as a blood surrogate fluid. These components when combined give the phantom high acoustic compatibility and lifelike mechanical properties. The phantom was developed using "at-home" purchasable components and 3D printing technology. The phantom was subsequently used to develop a 4D reconstruction algorithm of the pulsing vessel in MATLAB. In pattern with recent developments in medical imaging, the 4D reconstruction enables clinicians to view vessel wall motion in a 3D space without the need for manual intervention. The reconstruction algorithm also produces measured inner luminal areas and vessel wall thickness, providing further information relating to structural properties and stenosis, as well as elastic properties such as arterial stiffness, which could provide helpful markers for disease diagnosis. (c) 2021 Wiley Periodicals LLC.
引用
收藏
页数:21
相关论文
共 50 条
  • [1] Automated quantification of 4D ultrasound for carotid artery disease
    Xu, H
    Paik, DS
    Ross, B
    Sumanaweera, TS
    Hossack, J
    Jeffrey, RB
    Napel, S
    CARS 2000: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2000, 1214 : 666 - 670
  • [2] Improved Carotid Stenosis Quantification on Novel 4D/3D-Doppler Ultrasonography Indexing to the Common Carotid Artery
    Macharzina, Roland Richard
    Kocher, Sascha
    Messe, Steven R.
    Kammerer, Thomas
    Hoffmann, Fabian
    Vogt, Matthias
    Vach, Werner
    Fan, Nian
    Rastan, Aljoscha
    Neumann, Franz-Josef
    Zeller, Thomas
    ULTRASCHALL IN DER MEDIZIN, 2020, 41 (02): : 167 - 174
  • [3] 4D Flow MR Imaging of Ophthalmic Artery Flow in Patients with Internal Carotid Artery Stenosis
    Sekine, Tetsuro
    Takagi, Ryo
    Amano, Yasuo
    Murai, Yasuo
    Orita, Erika
    Fukushima, Yoshimitsu
    Matsumura, Yoshio
    Kumita, Shin-ichiro
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2018, 17 (01) : 13 - 20
  • [4] 4D Flow MRI and CFD Simulations of Pulsatile Flow in a Phantom Model of Arterial Stenosis: Visualizing the Vortex Dynamics
    Kazemi, Amirkhosro
    Nath, Ruponti
    Negahdar, Mj
    Stoddard, Marcus
    Amini, Amir A.
    MEDICAL IMAGING 2021: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2021, 11600
  • [5] Applicability of a novel right ventricular reconstruction method designed for 4D ultrasound
    Niemann, Petra S.
    Pinho, Luiz
    Balbach, Thomas
    Galuschky, Christian
    Brankenhagen, Michael
    Imus, Randal L.
    Broberg, Craig
    Silberbach, Michael
    Jerosch-Herold, Michael
    Sahn, David J.
    CIRCULATION, 2006, 114 (18) : 367 - 367
  • [6] 4D CBCT reconstruction with TV regularization on a dynamic software phantom
    Heylen, Rob
    Schramm, Georg
    Suetens, Paul
    Nuyts, Johan
    2019 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2019,
  • [7] Accuracy of duplex ultrasound for identification of greater than 50% carotid artery stenosis
    Powell, TI
    Mofidi, P
    Mehigan, D
    Sheehan, S
    Keaveny, TV
    MacErlaine, DP
    RADIOLOGY, 2001, 221 : 592 - 592
  • [8] Improved Carotid Stenoses Quantification on Novel 4D/3D-Doppler Ultrasonography Indexing to the Common Carotid Artery
    Macharzina, Roland R.
    Kocher, Sascha
    Hoffmann, Fabian
    Rastan, Aljoscha
    Fan, Nian
    Neumann, Franz-Josef
    Zeller, Thomas
    ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 2018, 38
  • [9] A novel deformable lung phantom for 4D radiotherapy verification
    Margeanu, M.
    Stroian, G.
    Heath, E.
    Seuntjens, J.
    MEDICAL PHYSICS, 2007, 34 (06) : 2649 - 2649
  • [10] 3D Reconstruction of Carotid Artery from Ultrasound Images
    Ma, Yingnan
    Wang, Zining
    Dai, Xu
    Chen, Bofeng
    Basu, Anup
    2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 4218 - 4221