Optical Gas Imaging for Accurate Leakage Source Measurement Based on Optical Flow Analysis

被引:0
|
作者
Wang, Qi [1 ,2 ,3 ]
Sun, Yunlong [2 ]
Pan, Xiatong [2 ]
Xing, Mingwei [2 ]
Zhao, Yong [1 ,2 ,3 ]
机构
[1] Northeastern Univ, State Key Lab Synthet Automat Proc Ind, Shenyang 110819, Peoples R China
[2] Northeastern Univ, Coll Informat Sci & Engn, Shenyang 110819, Peoples R China
[3] Hebei Key Lab Micronano Precis Opt Sensing & Measu, Qinhuangdao 066004, Peoples R China
基金
中国国家自然科学基金;
关键词
Optical variables measurement; Optical flow; Pollution measurement; Accuracy; Area measurement; Acoustic measurements; Current measurement; Optical sensors; Gases; Gas detectors; Farneback optical flow method; gas leakage measurement; imaging; infrared; location;
D O I
10.1109/TIM.2025.3529059
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Gas leakage measurement in industrial production is the key to eliminating accidents, ensuring that production can proceed smoothly and safely, and safeguarding the safety of personnel and the surrounding public. However, most of the existing gas leak point measurement methods use sensors for leak point measurement and cannot achieve long-range measurements. Gas infrared imaging can be applied in more industrial scenarios due to its advantage of wide-range noncontact telemetry. However, the problem with existing algorithms for leakage source measurement based on infrared images is mostly applicable for close-range detection of small targets, which implies that they cannot take advantage of the long-range, and wide-range applications of infrared gas imaging. When the contrast between gas and background is low or when large-scale leakage occurs, the existing measurement algorithms have low accuracy and are easily disturbed by noise, which does not meet the requirements of gas monitoring in industrial environments. To solve the issues, we propose a leak source measurement method based on the gas concentration and optical flow method. Here, the direct method (DM) and grid method (GM) are discussed to determine the region where the gas leakage source is located, which is uniquely combined with the main path direction of the gas, that is, obtained by the Farneback optical flow method. The experimental results show that the judgment and measurement error of GM combined with the Farneback optical flow method after Kalman filtering is within 65 pixels, that is, corresponding to a distance of 30 m from the leakage point can be controlled within 1.35 m, which can realize the automatic measurement of remote leakage points.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] YOLOGAS: An Intelligent Gas Leakage Source Detection Method Based on Optical Gas Imaging
    Wang, Qi
    Sun, Yunlong
    Jing, Yixuan
    Pan, Xiatong
    Xing, Mingwei
    IEEE SENSORS JOURNAL, 2024, 24 (21) : 35621 - 35627
  • [2] Estimation of Gas Velocity in Optical Gas Imaging Based on Deep Optical Flow Network
    Gu, Xiaoyu
    Gu, Xiaojing
    Ding, Jie
    Gu, Xingsheng
    ACTA OPTICA SINICA, 2024, 44 (18)
  • [3] Estimation of Gas Velocity in Optical Gas Imaging Based on Deep Optical Flow Network
    Gu, Xiaoyu
    Gu, Xiaojing
    Ding, Jie
    Gu, Xingsheng
    Guangxue Xuebao/Acta Optica Sinica, 44 (18):
  • [4] VERY ACCURATE MEASUREMENT OF FRINGE SHIFTS IN AN OPTICAL INTERFEROMETER STUDY OF GAS FLOW
    WERNER, FD
    LEADON, BM
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1953, 24 (02): : 121 - 124
  • [5] MEASUREMENT OF GAS FLOW TURBULENCE BY OPTICAL METHOD
    DEREVYAN.NF
    KUZNETSO.IL
    TROKHAN, AM
    DOKLADY AKADEMII NAUK SSSR, 1968, 180 (04): : 806 - &
  • [6] On Evaluating deep-learning-based Optical Flow Methods for Gas Velocity Estimation with Optical Gas Imaging Cameras
    Rangel, Johannes
    Duenas, Camilo
    Schmoll, Robert
    Kroll, Andreas
    AUTOMATED VISUAL INSPECTION AND MACHINE VISION IV, 2021, 11787
  • [7] Surface Flow Field Measurement Based on Optical Flow
    yu, Zhang
    Jiang Qinghui
    PROCEEDINGS OF THE 5TH INTERNATIONAL CONFERENCE ON CIVIL ENGINEERING AND TRANSPORTATION 2015, 2016, 30 : 1393 - 1399
  • [8] Accurate Source Simulation in Modern Optical Modeling and Analysis Software
    Jacobsen, David A.
    Freniere, Edward R.
    Gauvin, Michael
    PHYSICS AND SIMULATION OF OPTOELECTRONIC DEVICES XVIII, 2010, 7597
  • [9] OPTICAL DISTANCE MEASUREMENT BASED ON CONFOCAL IMAGING
    DAMM, T
    KEMPE, M
    STAMM, U
    OPTIK, 1991, 86 (04): : 144 - 147
  • [10] On Scene Flow Computation of Gas Structures with Optical Gas Imaging Cameras
    Rangel, Johannes
    Schmoll, Robert
    Kroll, Andreas
    2020 IEEE WINTER CONFERENCE ON APPLICATIONS OF COMPUTER VISION (WACV), 2020, : 174 - 182