Design of nonflammable mixed refrigerants based on the partial molar enthalpy difference in mixed-refrigerant Joule-Thomson refrigerators with/no pre-cooling stage

被引:0
|
作者
Wang, Yunxiao [1 ,2 ]
Zhao, Yanxing [1 ,2 ,3 ]
Sun, Yuwei [1 ,2 ]
Wang, Haocheng [1 ]
Gong, Maoqiong [1 ,2 ]
机构
[1] Chinese Acad Sci, Tech Inst Phys & Chem, Key Lab Cryogen, Beijing 100190, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[3] Qingdao Casfuture Res Inst Co Ltd, Qingdao 266109, Shandong, Peoples R China
来源
ADVANCES IN CRYOGENIC ENGINEERING: PROCEEDINGS OF THE CRYOGENIC ENGINEERING CONFERENCE, CEC 2023 | 2024年 / 1301卷
基金
中国国家自然科学基金;
关键词
D O I
10.1088/1757-899X/1301/1/012113
中图分类号
O414.1 [热力学];
学科分类号
摘要
Mixed-refrigerant Joule-Thomson refrigeration (MJTR) is an important cooling method at temperatures from 80 to 230 K. It can be used in cryosurgery, high-temperature superconductivity and sensor cooling etc. However, most of the studies are on nitrogen-hydrocarbon refrigerants, which are not allowed in applications where there is a special need to avoid flammability risks. Therefore, non-flammable mixed refrigerants were investigated in this study. The composition of the mixed refrigerant is a key factor in the system performance (refrigeration temperature, refrigeration capacity, etc). However, the purely mathematical optimization methods lack system knowledge in the optimization of the process, and may have the disadvantages of being a time-consuming process. In this study, the isothermal throttling effect of mixed refrigerants is optimized, and the optimization process is based on the partial molar enthalpy difference of each component. The method is based on thermodynamic properties and is time-saving relative to purely mathematical optimization techniques. Non-flammable mixed refrigerants (NFMR) with refrigeration temperatures from 100 K to 140 K were designed in this study. The results show that the designed mixed refrigerant has a higher COP compared to the reference. Argon has an advantage at refrigeration temperatures from 120 K to 140 K, while nitrogen has an advantage from 100 K to 120 K. In addition, mixed refrigerants for systems with pre-cooling stage were optimized and the results showed that the highest exergy efficiency is achieved at a pre-cooling temperature of 250 K. The exergy efficiencies with pre-cooling stage are nearly twice as high as those without that. Therefore, a pre-cooling stage for nonflammable mixed refrigerants is necessary where there is no requirement for system size.
引用
收藏
页数:8
相关论文
共 12 条
  • [1] The effective refrigeration temperature zone expressed by partial molar enthalpy difference of each component in mixed-refrigerant Joule-Thomson refrigerators
    Wang, Yunxiao
    Zhao, Yanxing
    Wang, Haocheng
    Gong, Maoqiong
    CRYOGENICS, 2022, 128
  • [2] Properties of gas mixtures and their use in mixed-refrigerant Joule-Thomson refrigerators
    Luo, E
    Gong, M
    Wu, J
    Zhou, Y
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS. 49A AND B, 2004, 710 : 1677 - 1686
  • [3] Steady-state thermodynamic simulation and structural design of the dephlegmator used in mixed-refrigerant Joule-Thomson refrigerators
    Li, Mei
    Gong, Maoqiong
    Guo, Hao
    Sun, Zhaohu
    Wu, Jianfeng
    APPLIED THERMAL ENGINEERING, 2016, 106 : 480 - 492
  • [4] Compositions optimization method based on the effective refrigeration effect for Mixed-refrigerant Joule-Thomson refrigerators cooling distributed-temperature heat loads
    Wang, Yunxiao
    Wang, Haocheng
    Zhao, Yanxing
    Gong, Maoqiong
    Wang, Kun
    Guo, Hao
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2023, 155 : 93 - 104
  • [5] Fast cool-down mixed-refrigerant Joule-Thomson cryocoolers used for cooling infrared devices
    Gong, MQ
    Wu, JF
    Liu, JL
    Liang, JT
    Luo, EC
    Zhou, Y
    INFRARED TECHNOLOGY AND APPLICATIONS XXVI, 2000, 4130 : 413 - 421
  • [6] Design of high efficiency mixed refrigerant Joule-Thomson refrigerator for cooling HTS cable
    Lee, Jisung
    Hwang, Gyuwan
    Jeong, Sangkwon
    Park, Byung Jun
    Han, Young Hee
    CRYOGENICS, 2011, 51 (07) : 408 - 414
  • [7] Analysis and Optimization of Liquid Air Energy Storage System Based on Mixed-refrigerant Joule-Thomson Refrigeration
    Sun, Yuwei
    Wang, Haocheng
    Guo, Hao
    Dong, Xueqiang
    Gong, Maoqiong
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2023, 44 (11): : 3032 - 3038
  • [8] Evaluation and analysis from pressure and component in the single-stage mixed-refrigerant Joule-Thomson cooler from 100 to 200 K
    Wang, Yunxiao
    Zhao, Yanxing
    Wang, Haocheng
    Gao, Shen
    Gong, Maoqiong
    ENERGY, 2025, 319
  • [9] Design of non-flammable mixed refrigerant Joule-Thomson refrigerator for precooling stage of high temperature superconducting power cable
    Lee, Cheonkyu
    Jin, Lingxue
    Park, Changgi
    Jeong, Sangkwon
    CRYOGENICS, 2017, 81 : 14 - 23
  • [10] Performance comparison of single-stage mixed-refrigerant joule-Thomson cycle and pure-gas reverse Brayton cycle at fixed-temperatures from 80 to 180 K
    Wang, H. C.
    Chen, G. F.
    Dong, X. Q.
    Zhao, Y. X.
    Guo, H.
    Gong, M. Q.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2017, 80 : 77 - 91